Sukanta Kumer Shill

Dr. Sukanta Kumer Shill

Deakin University - Waurn Ponds Campus
+1
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Construction and Building Materials
Verified
Journal Article
Closed access
Sukanta Kumer ShillSukanta Kumer Shill
Sukanta Kumer Shill
Safat Al-DeenSafat Al-Deen
Safat Al-Deen
Mahmud AshrafMahmud Ashraf
Mahmud Ashraf
WHWayne Hutchison
Wayne Hutchison

14 February 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Md. Akter HosenMd. Akter Hosen
Md. Akter Hosen
MSMahaad Issa Shammas
Mahaad Issa Shammas
Sukanta Kumer ShillSukanta Kumer Shill
Sukanta Kumer Shill
Safat Al-DeenSafat Al-Deen
Safat Al-Deen
MJMohd Zamin Jumaat
Mohd Zamin Jumaat
HHHuzaifa Hashim
Huzaifa Hashim
To limit the cross-sectional size of concrete structures, high-strength, lightweight concrete is preferred for the design and construction of structural elements. However, the main drawback of high-strength, lightweight concrete is its brittleness over normal-weight concrete. The ductility of concrete is a crucial factor, which plays an important role when the concrete structures are subjected to extreme situations, such as earthquakes and wind. This study aims to improve the ductility of high-strength, lightweight concrete by incorporating steel fibers. The palm oil clinker (POC)-based, high-strength, lightweight concrete specimens reinforced with steel fibers were prepared and their ductility was systematically examined. POC was used as aggregates and supplementary cementitious materials. Steel fibers from 0–1.50% (by volume), with an increment of 0.5%, were used in the concrete mix. Compression ductility, displacement ductility and energy ductility were used as indicators to evaluate the enhancement of ductility. Moreover, the compressive strength, flexural strength, stress-strain behavior, modulus of elasticity, load-displacement characteristics, energy absorption capacity and deformability of the concrete samples were investigated. The compression ductility, displacement ductility and energy ductility indexes were found to be increased by up to 472%, 140% and 568% compared to the control specimens (concrete with 0% steel fibers), respectively. Moreover, the deformability and energy absorption capacity of the concrete were increased by up to 566% and 125%, respectively. Therefore, POC-based, high-strength, fibrous, lightweight concrete could perform better than conventional concrete under extreme loading conditions as it showed significantly higher ductility.

1 November 2021 in Journal of Materials Research and Technology
Verified
Journal Article
Open access
Md. Akter HosenMd. Akter Hosen
Md. Akter Hosen
MSMahaad Issa Shammas
Mahaad Issa Shammas
Sukanta Kumer ShillSukanta Kumer Shill
Sukanta Kumer Shill
MJMohd Zamin Jumaat
Mohd Zamin Jumaat
UAU. Johnson Alengaram
U. Johnson Alengaram
YLYing Lin
Ying Lin

1 January 2018 in Construction and Building Materials
Verified
Journal Article
Closed access
Sukanta Kumer ShillSukanta Kumer Shill
Sukanta Kumer Shill
Safat Al-DeenSafat Al-Deen
Safat Al-Deen
Mahmud AshrafMahmud Ashraf
Mahmud Ashraf

Verified
Journal Article
Open access
PDF file
Sukanta Kumer ShillSukanta Kumer Shill
Sukanta Kumer Shill
EGEstela O. Garcez
Estela O. Garcez
Riyadh Al-AmeriRiyadh Al-Ameri
Riyadh Al-Ameri
Mahbube SubhaniMahbube Subhani
Mahbube Subhani
Fibre-reinforced polymer (FRP) rebars are being increasingly used to reinforce concrete structures that require long-term resistance to a corrosive environment. This study presents structural performance of large scale two-way concrete slabs reinforced with FRP rebars, and their performances were compared against conventional steel reinforced concrete. Both carbon FRP (CFRP) and basalt FRP (BFRP) were considered as steel replacement. Experimental results showed that the CFRP- and BFRP-RC slabs had approximately 7% and 4% higher cracking moment capacities than the steel-RC slab, respectively. The BFRP-RC slabs experienced a gradual decrease in the load capacity beyond the peak load, whereas the CFRP-RC slabs underwent a sharp decrease in load capacity, similar to the steel-RC slab. The BFRP-RC slabs demonstrated 1.72 times higher ductility than CFRP-RC slabs. The steel-RC slab was found to be safe against punching shear but failed due to flexural bending moment. The FRP-RC slabs were adequately safe against bending moment but failed due to punching shear. At failure load, the steel rebars were found to be yielded; however, the FRP rebars were not ruptured. FRP-RC slabs experienced a higher number of cracks and higher deflection compared to the steel-RC slab. However, FRP-RC slabs exhibited elastic recovery while unloading. Elastic recovery was not observed in the steel-RC slab. Additionally, the analytical load carrying capacity was validated against experimental values to investigate the efficacy of the current available standards (ACI 318-14 and ACI 440.1R-15) to predict the capacity of a two-way slab reinforced with CFRP or BFRP. The experimental load capacity of the CFRP-RC slabs was found to be approximately 1.20 times higher than the theoretical ultimate load capacity. However, the experimental load capacity of the BFRP-RC slabs was 6% lower than their theoretical ultimate load capacity.

1 January 2020 in Construction and Building Materials
Verified
Journal Article
Closed access
Sukanta Kumer ShillSukanta Kumer Shill
Sukanta Kumer Shill
Safat Al-DeenSafat Al-Deen
Safat Al-Deen
Mahmud AshrafMahmud Ashraf
Mahmud Ashraf
WHWayne Hutchison
Wayne Hutchison
MHMuhammad Monowar Hossain
Muhammad Monowar Hossain