Suraj Thyagaraj

Dr. Suraj Thyagaraj

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2017 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
SYSelda Yildiz
Selda Yildiz
Suraj ThyagarajSuraj Thyagaraj
Suraj Thyagaraj
NJNing Jin
Ning Jin
XZXiaodong Zhong
Xiaodong Zhong
SPSoroush Heidari Pahlavian
Soroush Heidari Pahlavian
KSKarim G. Sabra
Karim G. Sabra

4 April 2016 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
SPSoroush Heidari Pahlavian
Soroush Heidari Pahlavian
ABAlexander C. Bunck
Alexander C. Bunck
Suraj ThyagarajSuraj Thyagaraj
Suraj Thyagaraj
DGDaniel Giese
Daniel Giese
FLFrancis Loth
Francis Loth
BMBryn A. Martin
Bryn A. Martin

18 March 2021 in Fluids and Barriers of the CNS
Verified
Journal Article
Open access
PDF file
GWGwendolyn Williams
Gwendolyn Williams
Suraj ThyagarajSuraj Thyagaraj
Suraj Thyagaraj
AFAudrey Fu
Audrey Fu
JOJohn Oshinski
John Oshinski
DGDaniel Giese
Daniel Giese
BMBryn A. Martin
Bryn A. Martin
Background: Phase contrast magnetic resonance imaging, PC MRI, is a valuable tool allowing for non-invasive quantification of CSF dynamics, but has lacked adoption in clinical practice for Chiari malformation diagnostics. To improve these diagnostic practices, a better understanding of PC MRI based measurement agreement, repeatability, and reproducibility of CSF dynamics is needed. Methods: An anatomically realistic in vitro subject specific model of a Chiari malformation patient was scanned three times at five different scanning centers using 2D PC MRI and 4D Flow techniques to quantify intra-scanner repeatability, inter-scanner reproducibility, and agreement between imaging modalities. Peak systolic CSF velocities were measured at nine axial planes using 2D PC MRI, which were then compared to 4D Flow peak systolic velocity measurements extracted at those exact axial positions along the model. Results: Comparison of measurement results showed good overall agreement of CSF velocity detection between 2D PC MRI and 4D Flow (p = 0.86), fair intra-scanner repeatability (confidence intervals ± 1.5 cm/s), and poor inter-scanner reproducibility. On average, 4D Flow measurements had a larger variability than 2D PC MRI measurements (standard deviations 1.83 and 1.04 cm/s, respectively). Conclusion: Agreement, repeatability, and reproducibility of 2D PC MRI and 4D Flow detection of peak CSF velocities was quantified using a patient-specific in vitro model of Chiari malformation. In combination, the greatest factor leading to measurement inconsistency was determined to be a lack of reproducibility between different MRI centers. Overall, these findings may help lead to better understanding for application of 2D PC MRI and 4D Flow techniques as diagnostic tools for CSF dynamics quantification in Chiari malformation and related diseases.

26 September 2017 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Suraj ThyagarajSuraj Thyagaraj
Suraj Thyagaraj
SPSoroush Heidari Pahlavian
Soroush Heidari Pahlavian
LSLucas R. Sass
Lucas R. Sass
FLFrancis Loth
Francis Loth
MVMorteza Vatani
Morteza Vatani
BMBryn A. Martin
Bryn A. Martin
Goal: Develop and test an MRI-compatible hydrodynamic simulator of cerebrospinal fluid (CSF) motion in the cervical spinal subarachnoid space. Four anatomically realistic subject-specific models were created based on a 22-year-old healthy volunteer and a five-year-old patient diagnosed with Chiari I malformation. Methods : The in vitro models were based on manual segmentation of high-resolution T2-weighted MRI of the cervical spine. Anatomically realistic dorsal and ventral spinal cord nerve rootlets (NR) were added. Models were three dimensional (3-D) printed by stereolithography with 50-μm layer thickness. A computer controlled pump system was used to replicate the shape of the subject specific in vivo CSF flow measured by phase-contrast MRI. Each model was then scanned by T2-weighted and 4-D phase contrast MRI (4D flow). Results: Cross-sectional area, wetted perimeter, and hydraulic diameter were quantified for each model. The oscillatory CSF velocity field (flow jets near NR, velocity profile shape, and magnitude) had similar characteristics to previously reported studies in the literature measured by in vivo MRI. Conclusion: This study describes the first MRI-compatible hydrodynamic simulator of CSF motion in the cervical spine with anatomically realistic NR. NR were found to impact CSF velocity profiles to a great degree. Significance: CSF hydrodynamics are thought to be altered in craniospinal disorders such as Chiari I malformation. MRI scanning techniques and protocols can be used to quantify CSF flow alterations in disease states. The provided in vitro models can be used to test the reliability of these protocols across MRI scanner manufacturers and machines.

7 October 2015 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
BMBryn A. Martin
Bryn A. Martin
TYTheresia I. Yiallourou
Theresia I. Yiallourou
SPSoroush Heidari Pahlavian
Soroush Heidari Pahlavian
Suraj ThyagarajSuraj Thyagaraj
Suraj Thyagaraj
ABAlexander C. Bunck
Alexander C. Bunck
NSNikolaos Stergiopulos
Nikolaos Stergiopulos

1 October 2021 in Epileptic Disorders
Verified
Journal Article
Closed access
PDF file
NLNaiara Garcia Losarcos
Naiara Garcia Losarcos
JMJonathan Miller
Jonathan Miller
PFPhilip Fastenau
Philip Fastenau
SAShahram Amina
Shahram Amina
CBChristopher Bailey
Christopher Bailey
HLHans Lüders
Hans Lüders
Objective. For the treatment of mesial temporal lobe epilepsy on the language‐dominant side in patients at high risk of memory decline, we propose a minimally invasive diagnostic and treatment technique, adopting the principles of multiple hippocampal transections (MHT) using stereo‐electroencephalography‐guided radiofrequency (SEEG‐guided‐RF‐MHT). This new technique allows targeting of the longitudinal fibers in the hippocampus critical for seizure spreading, while sparing the transverse circuits which are considered important for memory processing and avoiding discomfort and longer post‐operatory recovery time associated with craniotomies. We report the efficacy and safety of this procedure in a preliminary observational study of cases.Methods. Five patients at high risk of memory decline, including three with non‐lesional hippocampi on MRI, had temporal lobe epilepsy (TLE) necessitating depth electrode implantation. A new strategy of SEEG electrode placement was used to mimic MHT. After confirming hippocampal seizure onset, all the patients had three linear ablations perpendicular to the amigdalohippocampal complex. The procedure was performed at the patient's bedside with the patient awake during the full length of the procedure.Results. Four out of five patients were seizure‐free (average follow up: 14–18 months). There were no associated complications. Visual inspection of brain MRI of patients at six months following SEEG‐guided RF‐MHT showed significant hippocampal volume preservation. Subjects who received the procedure in the dominant side reported no subjective memory complaints in the follow‐up clinic assessments at six months.Significance. Our preliminary seizure outcome seems very promising since the majority of our patients (four out of five patients) were seizure‐free. Since no lesions are made outside the amygdalo‐hippocampal complex using this technique and the temporal stem remains intact, more favorable memory and language outcome is expected in patients at high risk of memory decline.