Thomas P Hedman

Dr. Thomas P Hedman

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2023 in Journal of Pain Research
Verified
Journal Article
Open access
PDF file
MSMatthew Skoblar
Matthew Skoblar
THThomas P Hedman
Thomas P Hedman
ARAdam J Rogers
Adam J Rogers
GJGabriel P Jasper
Gabriel P Jasper
DBDouglas Beall
Douglas Beall
Purpose: Prospective evaluation of radiographic fusion outcomes in patients receiving instrumented posterior arthrodesis of the lumbar spine using a minimally invasive interspinous fixation device. Patients and Methods: All patients (n = 110) from a single US physician’s practice who received instrumented posterior arthrodesis of the lumbar spine with a minimally invasive interspinous fixation device in the calendar year 2020 were invited to return for a follow-up CT scan to radiographically assess fusion. Forty-three patients, representing 69 total treated levels, consented to participate and received a lumbar CT scan at a mean of 459 days post-surgery (177 to 652). The interspinous/interlaminar fusion was assessed by 3 independent radiologists using a novel grading scale. Spinous process fractures were also assessed. Results: 92.8% of the assessed levels were considered fused. There were no intraoperative spinous process fractures. There were 4 spinous process fractures (5.8%) identified on CT imaging, all of which were asymptomatic and healed without subsequent intervention. There were no instances of device mechanical failure or device-related reoperation. Conclusion: Instrumented posterior arthrodesis of the lumbar spine using a minimally invasive interspinous fixation device provides clinically meaningful fusion rates with no reoperations and a low risk of spinous process fracture or other device-related complications.

1 June 2024 in Journal of Pain Research
Verified
Journal Article
Open access
GBGanesan Baranidharan
Ganesan Baranidharan
BBBeatrice Bretherton
Beatrice Bretherton
RFRichard Feltbower
Richard Feltbower
JTJake Timothy
Jake Timothy
AKAlmas Khan
Almas Khan
THThomas P Hedman
Thomas P Hedman
Dove Press is a member of the Open Access Initiative, specializing in peer reviewed Medical Journals. View articlesor submit your research for publishing

19 July 2016 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
SSSharath Sundararaj
Sharath Sundararaj
PSPaul Slusarewicz
Paul Slusarewicz
MBMatt Brown
Matt Brown
THThomas P Hedman
Thomas P Hedman

5 April 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
THThomas P Hedman
Thomas P Hedman
ARAdam Rogers
Adam Rogers
Although the existence of highly prevalent pain, disability, and work time lost associated with discogenic low back pain is well known, the recognition of the culpability of universally present disc degradation and mechanical insufficiency in the first three decades of life is often overlooked. There is a corresponding “treatment gap” and no current interventions with demonstrated capabilities to address the pain and resist the usual progression of increasing structural failure of spinal tissues with increasing levels of pain and disability. This narrative review summarizes more than forty years of the literature describing the pathomechanics of progressive degradation of lumbar discs, with a focus on studies that implicate an increasing mechanical insufficiency in the etiology of early-stage chronic and recurrent discogenic low back pain. Topics highlighted in this review include the deleterious biological changes that begin soon after birth, stress intensification due to the loss of fluid phase load support, fatigue weakening and damage accumulation in non-regenerative tissue, disc tears, segmental instability, and the timeline for first incidence of chronic low back pain. The review concludes with preferred treatment characteristics and a brief summary of emerging treatment approaches.

1 August 2023 in Journal of Pain Research
Verified
Journal Article
Open access
PDF file
THThomas P Hedman
Thomas P Hedman
JYJames Yu
James Yu
HSHarwant Singh
Harwant Singh
TDTimothy R. Deer
Timothy R. Deer
Background: Genipin is a polymer-forming collagen bonding substance that can be dissolved in a buffered carrier and injected into disc annulus tissues. Therapeutic benefit is derived from the mechanical support provided by a large number of genipin polymers attached to collagen fibers in a degraded disc. Study Design/Setting: IRB-approved prospective, multi-site, single-arm, 12-month feasibility studies were undertaken in two countries to evaluate the safety and efficacy of the genipin-based implant for treating discogenic chronic low back pain (CLBP). Patient Sample: Twenty CLBP patients with symptomatic discs at one or two levels were enrolled in the study. Outcome Measures: The primary safety endpoint was serious adverse events at 1 month, and the primary efficacy endpoint was reduction of pain and disability at 3 months. Secondary efficacy endpoints included reduction of pain and disability at 2 weeks, 1 month, 6 months, and 12 months; reduction of flexion–extension instability; increase in segmental lordosis and rotation; and patient satisfaction. Methods: Fluoroscopic image-guidance was used to deliver two posterolateral injections of buffered genipin to each symptomatic disc. Flexion–extension radiographs were used to quantify joint kinematics at three time-points. Results: Clinically meaningful improvements in pain and disability scores were reported in 80% or more of patients from 2 weeks to 1 year post-treatment. For the more severely unstable joints, treatment significantly reduced the instability score from a pre-treatment level of 2.4 standard deviations above the mean for an asymptomatic population to the asymptomatic mean at the 3-month follow-up. Conclusion: These initial clinical data demonstrate the safety and efficacy of a genipin-based collagen tethering device capable of improving spinal joint stability while successfully addressing CLBP. This work merits additional randomized clinical studies.

1 January 2003
Verified
Conference Paper
Closed access
PDF file
THThomas P Hedman
Thomas P Hedman
SCShih-Youeng Chuang
Shih-Youeng Chuang
BSBaber Syed
Baber Syed
DGDean Gray
Dean Gray
This study involved an investigation into the effect of non-toxic crosslink augmentation on spinal discs on disc durability and joint stability. Non-destructive indentation techniques were developed to quantify annulus fibrosis material property degradation resulting from non-traumatic cyclic fatigue. Joint stability was assessed using two different natural zone measures. A non-toxic crosslinking reagent formulation reduced fatigue-induced viscoelastic relaxation by two- to three-fold compared to controls. The same treatment was found to produce a four-fold reduction of instability scores. Stabilization was observed to be greater in the more mechanically unstable discs.