Tadesse Ghirmai

Dr. Tadesse Ghirmai

University of Washington Bothell, Bothell, Washington, USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2017 in Technologies
Verified
Journal Article
Open access
PDF file
MSManuja Sharma
Manuja Sharma
KBKarinne Barbosa
Karinne Barbosa
VHVictor Ho
Victor Ho
DGDevon Griggs
Devon Griggs
TGTadesse Ghirmai
Tadesse Ghirmai
Hung CaoHung Cao
Hung Cao
Blood pressure (BP) is one of the most important monitoring parameters in clinical medicine. For years, the cuff-based sphygmomanometer and the arterial invasive line have been the gold standards for care professionals to assess BP. During the past few decades, the wide spread of the oscillometry-based BP arm or wrist cuffs have made home-based BP assessment more convenient and accessible. However, the discontinuous nature, the inability to interface with mobile applications, the relative inaccuracy with movement, and the need for calibration have rendered those BP oscillometry devices inadequate for next-generation healthcare infrastructure where integration and continuous data acquisition and communication are required. Recently, the indirect approach to obtain BP values has been intensively investigated, where BP is mathematically derived through the “Time Delay” in propagation of pressure waves in the vascular system. This holds promise for the realization of cuffless and continuous BP monitoring systems, for both patients and healthy populations in both inpatient and outpatient settings. This review highlights recent efforts in developing these next-generation blood pressure monitoring devices and compares various mathematical models. The unmet challenges and further developments that are crucial to develop “Time Delay”-based BP devices are also discussed.

5 June 2020 in Technologies
Verified
Journal Article
Open access
PDF file
Sadaf SarafanSadaf Sarafan
Sadaf Sarafan
TLTai Le
Tai Le
ANAmir mohammad Naderi
Amir mohammad Naderi
QNQuoc Dinh Nguyen
Quoc Dinh Nguyen
BKBrandon Tiang-Yu Kuo
Brandon Tiang-Yu Kuo
Hung CaoHung Cao
Hung Cao
Monitoring of fetal electrocardiogram (fECG) would provide useful information about fetal wellbeing as well as any abnormal development during pregnancy. Recent advances in flexible electronics and wearable technologies have enabled compact devices to acquire personal physiological signals in the home setting, including those of expectant mothers. However, the high noise level in the daily life renders long-entrenched challenges to extract fECG from the combined fetal/maternal ECG signal recorded in the abdominal area of the mother. Thus, an efficient fECG extraction scheme is a dire need. In this work, we intensively explored various extraction algorithms, including template subtraction (TS), independent component analysis (ICA), and extended Kalman filter (EKF) using the data from the PhysioNet 2013 Challenge. Furthermore, the modified data with Gaussian and motion noise added, mimicking a practical scenario, were utilized to examine the performance of algorithms. Finally, we combined different algorithms together, yielding promising results, with the best performance in the F1 score of 92.61% achieved by an algorithm combining ICA and TS. With the data modified by adding different types of noise, the combination of ICA–TS–ICA showed the highest F1 score of 85.4%. It should be noted that these combined approaches required higher computational complexity, including execution time and allocated memory compared with other methods. Owing to comprehensive examination through various evaluation metrics in different extraction algorithms, this study provides insights into the implementation and operation of state-of-the-art fetal and maternal monitoring systems in the era of mobile health.

5 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Sadaf SarafanSadaf Sarafan
Sadaf Sarafan
TLTai Le
Tai Le
MLMichael P. H. Lau
Michael P. H. Lau
AHAfshan Hameed
Afshan Hameed
TGTadesse Ghirmai
Tadesse Ghirmai
Hung CaoHung Cao
Hung Cao
Fetal electrocardiogram (fECG) assessment is essential throughout pregnancy to monitor the wellbeing and development of the fetus, and to possibly diagnose potential congenital heart defects. Due to the high noise incorporated in the abdominal ECG (aECG) signals, the extraction of fECG has been challenging. And it is even a lot more difficult for fECG extraction if only one channel of aECG is provided, i.e., in a compact patch device. In this paper, we propose a novel algorithm based on the Ensemble Kalman filter (EnKF) for non-invasive fECG extraction from a single-channel aECG signal. To assess the performance of the proposed algorithm, we used our own clinical data, obtained from a pilot study with 10 subjects each of 20 min recording, and data from the PhysioNet 2013 Challenge bank with labeled QRS complex annotations. The proposed methodology shows the average positive predictive value (PPV) of 97.59%, sensitivity (SE) of 96.91%, and F1-score of 97.25% from the PhysioNet 2013 Challenge bank. Our results also indicate that the proposed algorithm is reliable and effective, and it outperforms the recently proposed extended Kalman filter (EKF) based algorithm.

9 September 2016 in Sensors
Verified
Journal Article
Open access
PDF file
TGTadesse Ghirmai
Tadesse Ghirmai
For efficient and accurate estimation of the location of objects, a network of sensors can be used to detect and track targets in a distributed manner. In nonlinear and/or non-Gaussian dynamic models, distributed particle filtering methods are commonly applied to develop target tracking algorithms. An important consideration in developing a distributed particle filtering algorithm in wireless sensor networks is reducing the size of data exchanged among the sensors because of power and bandwidth constraints. In this paper, we propose a distributed particle filtering algorithm with the objective of reducing the overhead data that is communicated among the sensors. In our algorithm, the sensors exchange information to collaboratively compute the global likelihood function that encompasses the contribution of the measurements towards building the global posterior density of the unknown location parameters. Each sensor, using its own measurement, computes its local likelihood function and approximates it using a Gaussian function. The sensors then propagate only the mean and the covariance of their approximated likelihood functions to other sensors, reducing the communication overhead. The global likelihood function is computed collaboratively from the parameters of the local likelihood functions using an average consensus filter or a forward-backward propagation information exchange strategy.

8 February 2024 in Physical and Engineering Sciences in Medicine
Verified
Journal Article
Closed access
PDF file
NMNastaran Mansourian
Nastaran Mansourian
Sadaf SarafanSadaf Sarafan
Sadaf Sarafan
FAFarah Torkamani Azar
Farah Torkamani Azar
TGTadesse Ghirmai
Tadesse Ghirmai
Hung CaoHung Cao
Hung Cao