Sergey Taskaev

Prof. Sergey Taskaev

Budker Institute of Nuclear Physics
+1
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 1998 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
BBB.F. Bayanov
B.F. Bayanov
VBV.P. Belov
V.P. Belov
EBE.D. Bender
E.D. Bender
MBM.V. Bokhovko
M.V. Bokhovko
GDG.I. Dimov
G.I. Dimov
Sergey TaskaevSergey Taskaev
Sergey Taskaev

21 April 2021 in Biology
Verified
Journal Article
Open access
PDF file
Sergey TaskaevSergey Taskaev
Sergey Taskaev
EBEvgeny Berendeev
Evgeny Berendeev
MBMarina Bikchurina
Marina Bikchurina
TBTimofey Bykov
Timofey Bykov
DKDmitrii Kasatov
Dmitrii Kasatov
GVGleb Dmitrievich Verkhovod
Gleb Dmitrievich Verkhovod
A compact accelerator-based neutron source has been proposed and created at the Budker Institute of Nuclear Physics in Novosibirsk, Russia. An original design tandem accelerator is used to provide a proton beam. The proton beam energy can be varied within a range of 0.6–2.3 MeV, keeping a high-energy stability of 0.1%. The beam current can also be varied in a wide range (from 0.3 mA to 10 mA) with high current stability (0.4%). In the device, neutron flux is generated as a result of the 7Li(p,n)7Be threshold reaction. A beam-shaping assembly is applied to convert this flux into a beam of epithermal neutrons with characteristics suitable for BNCT. A lot of scientific research has been carried out at the facility, including the study of blistering and its effect on the neutron yield. The BNCT technique is being tested in in vitro and in vivo studies, and the methods of dosimetry are being developed. It is planned to certify the neutron source next year and conduct clinical trials on it. The neutron source served as a prototype for a facility created for a clinic in Xiamen (China).

5 November 2015 in Physics of Particles and Nuclei
Verified
Journal Article
Closed access
PDF file
Sergey TaskaevSergey Taskaev
Sergey Taskaev

1 November 2004 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
BBB Bayanov
B Bayanov
VBV Belov
V Belov
VKV Kindyuk
V Kindyuk
EOE Oparin
E Oparin
Sergey TaskaevSergey Taskaev
Sergey Taskaev

1 September 2018 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
LZL. Zaidi
L. Zaidi
MBM. Belgaid
M. Belgaid
Sergey TaskaevSergey Taskaev
Sergey Taskaev
RKR. Khelifi
R. Khelifi

Verified
Journal Article
Open access
PDF file
MVMariya A. Vorobyeva
Mariya A. Vorobyeva
MDMaya A. Dymova
Maya A. Dymova
DNDarya Novopashina
Darya Novopashina
EKElena Kuligina
Elena Kuligina
VTValentina Timoshenko
Valentina Timoshenko
AVAlya Venyaminova
Alya Venyaminova
Boron neutron capture therapy (BNCT) is a binary radiotherapeutic approach to the treatment of malignant tumors, especially glioblastoma, the most frequent and incurable brain tumor. For successful BNCT, a boron-containing therapeutic agent should provide selective and effective accumulation of 10B isotope inside target cells, which are then destroyed after neutron irradiation. Nucleic acid aptamers look like very prospective candidates for carrying 10B to the tumor cells. This study represents the first example of using 2′-F-RNA aptamer GL44 specific to the human glioblastoma U-87 MG cells as a boron delivery agent for BNCT. The closo-dodecaborate residue was attached to the 5′-end of the aptamer, which was also labeled by the fluorophore at the 3′-end. The resulting bifunctional conjugate showed effective and specific internalization into U-87 MG cells and low toxicity. After incubation with the conjugate, the cells were irradiated by epithermal neutrons on the Budker Institute of Nuclear Physics neutron source. Evaluation of the cell proliferation by real-time cell monitoring and the clonogenic test revealed that boron-loaded aptamer decreased specifically the viability of U-87 MG cells to the extent comparable to that of 10B-boronophenylalanine taken as a control. Therefore, we have demonstrated a proof of principle of employing aptamers for targeted delivery of boron-10 isotope in BNCT. Considering their specificity, ease of synthesis, and large toolkit of chemical approaches for high boron-loading, aptamers provide a promising basis for engineering novel BNCT agents.