TAYYAB ALI

Mr. TAYYAB ALI

International Islamic University, Islamabad, Islamabad, Islāmābād, Pakistan

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2022 in Energies
Verified
Journal Article
Open access
PDF file
TATAYYAB ALI
TAYYAB ALI
SMSuheel Abdullah Malik
Suheel Abdullah Malik
ADAMIL DARAZ
AMIL DARAZ
Sheraz AslamSheraz Aslam
Sheraz Aslam
TATamim Alkhalifah
Tamim Alkhalifah
Frequency, voltage, and power flow between different control zones in an interconnected power system are used to determine the standard quality of power. Therefore, the voltage and frequency control in an IPS is of vital importance to maintaining real and reactive power balance under varying load conditions. In this paper, a dandelion optimizer (DO)-based proportional-integral-proportional-derivative (PI-PD) controller is investigated for a realistic multi-area, multi-source, realistic IPS with nonlinearities. The output responses of the DO-based PI-PD were compared with the hybrid approach using artificial electric field-based fuzzy PID algorithm (HAEFA), Archimedes optimization algorithm (AOA)-based PI-PD, learning performance-based behavior optimization (LPBO)-based PI-PD and modified particle swarm optimization (MPSO)-based PI-PD control schemes in a two-area network with 10% step load perturbation (SLP). The proposed strategy was also investigated in a two- and three-area IPS in the presence of different nonlinearities and SLPs. The simulation results and the comprehensive comparison between the different control schemes clearly confirm that the proposed DO-based PI-PD is very effective for realistic, multi-area multi-source IPS with nonlinearities.

21 February 2023 in Energies
Verified
Journal Article
Open access
PDF file
TATAYYAB ALI
TAYYAB ALI
SMSuheel Abdullah Malik
Suheel Abdullah Malik
ADAMIL DARAZ
AMIL DARAZ
MAMuhammad Adeel
Muhammad Adeel
Sheraz AslamSheraz Aslam
Sheraz Aslam
Herodotos HerodotouHerodotos Herodotou
Herodotos Herodotou
Existing interconnected power systems (IPSs) are being overloaded by the expansion of the industrial and residential sectors together with the incorporation of renewable energy sources, which cause serious fluctuations in frequency, voltage, and tie-line power. The automatic voltage regulation (AVR) and load frequency control (LFC) loops provide high quality power to all consumers with nominal frequency, voltage, and tie-line power deviation, ensuring the stability and security of IPS in these conditions. In this paper, a proportional integral derivative (PID) controller is investigated for the effective control of a four-area IPS. Each IPS area has five generating units including gas, thermal reheat, hydro, and two renewable energy sources, namely wind and solar photovoltaic plants. The PID controller was tuned by a meta-heuristic optimization algorithm known as a gradient-based optimizer (GBO). The integral of time multiplied by squared value of error (ITSE) was utilized as an error criterion for the evaluation of the fitness function. The voltage, frequency, and tie-line power responses of GBO-PID were evaluated and compared with integral–proportional derivative (GBO-I-PD), tilt integral derivative (GBO-TID), and integral–proportional (GBO-I-P) controllers with 5% step load perturbation (SLP) provided in each of the four areas. Comprehensive comparisons between GBO-PID and other control methodologies revealed that the proposed GBO-PID controller provides superior voltage, frequency, and tie-line power responses in each area. The reliability and efficacy of GBO-PID methodology were further validated with variations in the turbine time constant and speed regulation over a range of  ± 25%. It is evident from the outcomes of the sensitivity analysis that the proposed GBO-PID control methodology is very reliable and can successfully stabilize the deviations in terminal voltage, load frequency, and tie-line power with a shorter settling time in a four-area IPS.