As an innovative technology, the impedance-based technique has been extensively studied for the structural health monitoring (SHM) of various civil structures. The technique’s advantages include cost-effectiveness, ease of implementation on a complex structure, robustness to early-stage failures, and real-time damage assessment capabilities. Nonetheless, very few studies have taken those advantages for monitoring the health status and the structural condition of wind turbine structures. Thus, this paper is motivated to give the reader a general outlook of how the impedance-based SHM technology has been implemented to secure the safety and serviceability of the wind turbine structures. Firstly, possible structural failures in wind turbine systems are reviewed. Next, physical principles, hardware systems, damage quantification, and environmental compensation algorithms are outlined for the impedance-based technique. Afterwards, the current status of the application of this advanced technology for health monitoring and damage identification of wind turbine structural components such as blades, tower joints, tower segments, substructure, and the foundation are discussed. In the end, the future perspectives that can contribute to developing efficient SHM systems in the green energy field are proposed.

25 September 2021 in Buildings
Verified
Journal Article
Open access
PDF file
Thanh-Cao LeThanh-Cao Le
Thanh-Cao Le
Thi Tuong Vy PhanThi Tuong Vy Phan
Thi Tuong Vy Phan
TNTrung Hau Trung Nguyen
Trung Hau Trung Nguyen
Duc-Duy HoDuc-Duy Ho
Duc-Duy Ho
THThanh-Canh Huynh
Thanh-Canh Huynh
This study proposes a cost-effective prestress monitoring method for post-tensioned reinforced concrete (RC) beams using a smart strand. Firstly, the concept of a piezoelectric-based smart strand and its implementation for prestress force monitoring are developed. The smart strand is prepared by embedding inexpensive and high-sensitivity electromechanical impedance (EMI) sensors in a steel strand. Next, the feasibility of the proposed method is experimentally verified for prestress force monitoring of a simple supported post-tensioned RC beam. A smart strand prototype is fabricated and embedded into a 6.4 m RC beam which is then prestressed with different levels. For each prestress level, the EMI responses of the smart tendon are measured and the EMI features are extracted for prestress force monitoring. The results showed that the EMI signals of the smart strand showed strong resonant peaks that varied sensitively to the prestress level of the beam. The prestress change in the prestressed RC beam was successfully estimated by using linear regression models of the EMI features.

1 January 2021 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
Thanh-Cao LeThanh-Cao Le
Thanh-Cao Le
Duc-Duy HoDuc-Duy Ho
Duc-Duy Ho
THThanh-Canh Huynh
Thanh-Canh Huynh
VBVan-Sy Bach
Van-Sy Bach
Among vibration‐based damage detection methods, one of the effective approaches for damage localization is the modal strain energy method. In this paper, the modal strain energy method is developed for damage detection in plate‐like structures with various boundary conditions. Firstly, the theory of the modal strain energy method is briefly outlined. In order to overcome the limitation of measuring points, a central difference method is newly employed to compute the partial differential terms in the modal strain energy formula. Finite element analysis is conducted on an aluminum thin plate to obtain the mode shapes before and after the occurrence of damage. Feasibility of the proposed method is verified by investigating plates with different types of boundary conditions. A damage index is presented to identify the location and extent of crack in the plate‐like structures. The analytical results show that the proposed method accurately identifies the crack in the plate structure with various types of boundary conditions by using appropriate mode shapes and damage threshold.

1 January 2022 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
Thanh-Cao LeThanh-Cao Le
Thanh-Cao Le
Duc-Duy HoDuc-Duy Ho
Duc-Duy Ho
CNChi-Thien Nguyen
Chi-Thien Nguyen
THThanh-Canh Huynh
Thanh-Canh Huynh
This paper presents an improvement to the modal strain energy (MSE) method for identifying structural damages in plate‐type structures. A two‐step MSE‐based damage localization procedure, including a global step and a local step, is newly proposed to enhance the accuracy of detecting the location of structural damage. Firstly, the global step uses the mode shape data on the whole plate to locate the potentially damaged areas. Then, MSE is applied with a more dense mesh size on these local areas to detect damage in more detail. The proposed procedure’s feasibility is verified by analyzing an aluminum plate with various damaged scenarios. This study uses finite element analysis to acquire the plate's natural frequencies and mode shapes in intact and damaged states. A set of two damage detection capacity indicators are also newly presented to evaluate the precision of the proposed procedure. The diagnostic results demonstrate that the proposed approach uses less modal data than the original MSE method and accurately identifies the damage's locations in the plates with various edge conditions. Moreover, the combination of three first mode shapes and a damage threshold of 40% of the maximum normalized damage index gives the best results of damage localization.

16 November 2021 in Buildings
Verified
Journal Article
Open access
PDF file
TNTrung Hau Trung Nguyen
Trung Hau Trung Nguyen
Thi Tuong Vy PhanThi Tuong Vy Phan
Thi Tuong Vy Phan
Thanh-Cao LeThanh-Cao Le
Thanh-Cao Le
Duc-Duy HoDuc-Duy Ho
Duc-Duy Ho
THThanh-Canh Huynh
Thanh-Canh Huynh
This study investigates the dynamic characteristics of a smart PZT interface mounted on a prestressed anchorage to verify the numerical feasibility of the admittance-based anchor force monitoring technique. Firstly, the admittance-based anchor force monitoring technique through a single-mount PZT interface is outlined. The admittance response of the PZT interface-anchorage system is theoretically derived to show the proof-of-concept of the technique for anchor force monitoring. Secondly, a finite element model corresponding to a well-established experimental model in the literature is constructed. The effect of anchor force is equivalently treated by the contact stiffness and damping parameters at the bottom surface of the anchorage. Thirdly, the admittance and the impedance responses are numerically analyzed and compared with the experimental data to evaluate the accuracy of the numerical modelling technique. Fourthly, the local dynamics of the PZT interface are analyzed by modal analysis to determine vibration modes that are sensitive to the change in the contact stiffness (i.e., representing the anchor force). Finally, the admittance responses corresponding to the sensitive vibration modes are numerically analyzed under the change in the contact stiffness. The frequency shift and the admittance change are quantified by statistical damage indices to verify the numerical feasibility of the anchor force monitoring technique via the smart PZT interface. The study is expected to provide a reference numerical model for the design of the single-point mount PZT interface.

16 August 2023 in Buildings
Verified
Journal Article
Open access
PDF file
MNMinh-Huy Nguyen
Minh-Huy Nguyen
TNTruong Tran De Nhat
Truong Tran De Nhat
Thanh-Cao LeThanh-Cao Le
Thanh-Cao Le
Duc-Duy HoDuc-Duy Ho
Duc-Duy Ho
For cable structures, the tension force is one of the main factors showing the structure’s health. If the tension force falls below a safe level during construction or operation, it can lead to partial or complete the structural failure, posing a risk to the people’s safety. In this study, a parallel structural health monitoring approach of the vibration-based and impedance-based methods is proposed to identify the tension force in cable structures. Firstly, a cable structure including the anchorage is simulated using a finite element model to obtain the vibration and impedance responses. The numerical results are verified with the experimental ones of the previous studies. Then, the parallel approach combining the above two methods is presented to determine the tension force. For the vibration-based method, the tension force is estimated by the natural frequencies. For the impedance-based method, the tension force is estimated by the mean absolute percentage deviation (MAPD) index and the artificial neural network (ANN). Finally, the tension force estimation results are compared and assessed. By using the parallel approach, the reliability and accuracy of the tension force identification results are guaranteed.