Gunjanaporn Tochaikul

Ms. Gunjanaporn Tochaikul

Rangsit University, Pathum Thani, Thailand
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2022 in Kerntechnik
Verified
Journal Article
Closed access
GTGunjanaporn Tochaikul
Gunjanaporn Tochaikul
APArchara Phattanasub
Archara Phattanasub
PKPiyatida Khemkham
Piyatida Khemkham
KSKanjanaporn Saengthamthawee
Kanjanaporn Saengthamthawee
NDNuttapong Danthanavat
Nuttapong Danthanavat
NMNutthapong Moonkum
Nutthapong Moonkum
Radioactive waste is generated from activities that utilize nuclear materials such as nuclear medicine or power plants. Depending on their half-life, they emit radiation continuously, ranging from seconds to millions of years. Exposure to ionizing radiation can cause serious harm to humans and the environment. Therefore, special attention is paid to the management of radioactive waste in order to deal with its large quantity and dangerous levels. Current treatment technologies are still being developed to improve efficiency in reducing the hazard level and waste volume, to minimize the impact on living organisms. Thus, the aim of this study was to provide an overview of the global radioactive waste treatment technologies that have been released in 2019–2021.

1 November 2022 in Materials Research Innovations
Verified
Journal Article
Closed access
Nutthapong MoonkumNutthapong Moonkum
Nutthapong Moonkum
CPChalermchai Pilapong
Chalermchai Pilapong
KDKrai Daowtak
Krai Daowtak
GTGunjanaporn Tochaikul
Gunjanaporn Tochaikul
In radiology, radiation shielding is important for protection especially with diagnostic radiation, such as diagnostic X-ray, because radiation exposure can damage cellular DNA. Currently, lead is the most common radiation shielding but it poses environmental hazards due to its toxicity. This research aims to study a non-lead radiation shielding and to evaluate its effectiveness of radiation protection. We studied radiation absorption properties from primary and secondary radiations from shielding composed of silicone rubber and BaSO4 and Bi2O3 in different proportions. The results showed that the shielding material at 70% BaSO4 and Bi2O3 has the ability to reduce radiation doses from 120 kVp X-rays and has absorption properties of 90.19, 94.87% in primary and 92.72, 97.48% in secondary radiation. In addition, the silicone rubber shielding materials mixed with BaSO4 and Bi2O3 are environment-friendly, flexible and have great shielding performance in reducing diagnostic X-ray exposure.

4 January 2025 in Polymers
Verified
Journal Article
Open access
PDF file
GTGunjanaporn Tochaikul
Gunjanaporn Tochaikul
Nuttapol TanadchangsaengNuttapol Tanadchangsaeng
Nuttapol Tanadchangsaeng
APAnuchan Panaksri
Anuchan Panaksri
Nutthapong MoonkumNutthapong Moonkum
Nutthapong Moonkum
This study investigates the development of epoxy–resin composites reinforced with coral-derived calcium carbonate (CaCO3) fillers for enhanced radiation shielding and mechanical properties. Leveraging the high calcium content and density of coral, composites were prepared with filler weight fractions of 0%, 25%, and 50%. SEM and EDS analyses revealed that higher filler concentrations (50%) increased particle agglomeration, affecting matrix uniformity. Mechanical testing showed that while the tensile and flexural strengths decreased with the increased filler content, the compressive strength significantly improved, reaching 135 MPa at a 50% coral content. Radiation shielding evaluations demonstrated enhanced attenuation with a higher filler content, achieving 39.63% absorption at 60 kVp for the 50% coral composite. However, the shielding efficiency was notably lower compared to lead, which achieves over 99% absorption at similar energy levels. These quantitative comparisons highlight the material’s limitations in high-radiation environments but emphasize its suitability for moderate shielding applications. Despite their lower shielding efficiency, the composites provide an environmentally friendly and non-toxic alternative to lead, aligning with sustainability goals. Future work should focus on optimizing filler dispersion, mitigating agglomeration, and exploring hybrid systems to enhance the shielding efficiency and mechanical properties. The further quantitative evaluation of parameters such as Zeff and cross-sections is recommended to comprehensively assess the material’s performance.

13 January 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Nutthapong MoonkumNutthapong Moonkum
Nutthapong Moonkum
CPChalermchai Pilapong
Chalermchai Pilapong
KDKrai Daowtak
Krai Daowtak
GTGunjanaporn Tochaikul
Gunjanaporn Tochaikul
Radiation protection in radiology is important because radiation may cause harm to the human body. The equipment for radiation protection is essential to ensure safe operations. Currently, there is widespread research on lead-free radiation shielding material. The aim of this research was to study lead-free material containing epoxy and iodine contrast media that was easy to form, low in cost, and environmentally friendly. The results showed that 2-cm material thickness with a concentration of 20% iodine had the greatest properties of radiation attenuate in the peak potential applied at technique 60–120 kVp, but the structure and strength of the shielding materials were decreased in accordance with increasing concentrations of iodine contrast media. It can be concluded that the lead-free epoxy radiation-shielding materials are able to absorb radiation at energy levels of 60–120 kVp. However, with improvement on homogeneity in the future, it could be used as a refractory shielding material in the radiology department.

19 January 2023 in Radiological Physics and Technology
Verified
Journal Article
Open access
PDF file
NMNutthapong Moonkum
Nutthapong Moonkum
SJSupattra Jitchom
Supattra Jitchom
SSSorasit Sukaram
Sorasit Sukaram
NNNichanard Nimtrakool
Nichanard Nimtrakool
PBPongviroj Boonrat
Pongviroj Boonrat
GTGunjanaporn Tochaikul
Gunjanaporn Tochaikul
The COVID-19 pandemic has resulted in a large increase in the number of patients admitted to hospitals. Radiological technologists (RTs) are often required to perform portable chest X-ray radiography on these patients. Normally, when performing a portable X-ray, radiation protection equipment is critical as it reduces the scatter radiation dose to hospital workers. However, during the pandemic, the use of a lead shield caused a heavy weight burden on workers who were responsible for a large number of patients. This study aimed to investigate scatter radiation doses received at various distances, directions, and positions. Radiation measurements were performed using the PBU-60 whole body phantom to determine scatter radiation doses at 100–200 cm and eight different angles around the phantom. The tests were conducted with and without lead shielding. Additionally, the doses were compared using the paired t test (p < 0.005) to determine suitable positions for workers who did not wear lead protection that adhered to radiation safety requirements. Scatter radiation doses of all 40 tests showed a highest and lowest value of 1285.5 nGy at 100 cm in the anteroposterior (AP) semi upright position and 134.7 nGy at 200 cm in the prone position, respectively. Correlation analysis between the dosimeter measurement and calculated inverse square law showed good correlation, with an R2 value of 0.99. Without lead shielding, RTs must stay at a distance greater than 200 cm from patients for both vertical and horizontal beams to minimize scatter exposure. This would allow for an alternative way of performing portable chest radiography for COVID-19 patients without requiring lead shielding.

30 March 2023 in Radiation Effects and Defects in Solids
Verified
Journal Article
Closed access
GTGunjanaporn Tochaikul
Gunjanaporn Tochaikul
CPChalermchai Pilapong
Chalermchai Pilapong
KDKrai Daowtak
Krai Daowtak
Nutthapong MoonkumNutthapong Moonkum
Nutthapong Moonkum
The chest X-ray is a simple technique for routine medical examinations. Patients under investigation (PUI) might be exposed to radiation over the recommended dose due to the necessity of repeated X-rays. The aim of this research was to study the effects of repeated chest X-rays on peripheral blood mononuclear cells (PBMCs). The study determined characteristics of PBMCs by inverted microscope and flow cytometry after single and repeated X-ray exposure doses. The morphology of PBMCs showed cell differentiation to mesenchymal stromal cells throughout the plate and the trend of cells to differentiate in control groups more than single exposure and repeated irradiation. The cell growth of PBMCs was decreased after 10 days following repeated X-ray exposure as compared to controls. The overall results indicated that low-dose radiation from diagnostic X-rays affected PBMCs possibly indicating harmful radiation exposure. Future clinical studies will necessitate a larger sample size to more clearly assess cellular changes.