Toshiki Nagai

Dr. Toshiki Nagai

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2024 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
AAAmal Alfaraj
Amal Alfaraj
TNToshiki Nagai
Toshiki Nagai
HAHawra AlQallaf
Hawra AlQallaf
Wei-Shao LinWei-Shao Lin
Wei-Shao Lin
Objectives: This review aims to explore the applications of artificial intelligence (AI) in prosthodontics and implant dentistry, focusing on its performance outcomes and associated ethical concerns. Materials and Methods: Following the PRISMA guidelines, a search was conducted across databases such as PubMed, Medline, Web of Science, and Scopus. Studies published between January 2022 and May 2024, in English, were considered. The Population (P) included patients or extracted teeth with AI applications in prosthodontics and implant dentistry; the Intervention (I) was AI-based tools; the Comparison (C) was traditional methods, and the Outcome (O) involved AI performance outcomes and ethical considerations. The Newcastle–Ottawa Scale was used to assess the quality and risk of bias in the studies. Results: Out of 3420 initially identified articles, 18 met the inclusion criteria for AI applications in prosthodontics and implant dentistry. The review highlighted AI’s significant role in improving diagnostic accuracy, treatment planning, and prosthesis design. AI models demonstrated high accuracy in classifying dental implants and predicting implant outcomes, although limitations were noted in data diversity and model generalizability. Regarding ethical issues, five studies identified concerns such as data privacy, system bias, and the potential replacement of human roles by AI. While patients generally viewed AI positively, dental professionals expressed hesitancy due to a lack of familiarity and regulatory guidelines, highlighting the need for better education and ethical frameworks. Conclusions: AI has the potential to revolutionize prosthodontics and implant dentistry by enhancing treatment accuracy and efficiency. However, there is a pressing need to address ethical issues through comprehensive training and the development of regulatory frameworks. Future research should focus on broadening AI applications and addressing the identified ethical concerns.

14 May 2024 in Journal of Prosthodontics
Verified
Journal Article
Open access
TNToshiki Nagai
Toshiki Nagai
AAAmal Alfaraj
Amal Alfaraj
TCTien‐Min G Chu
Tien‐Min G Chu
CYChao‐Chieh Yang
Chao‐Chieh Yang
Wei-Shao LinWei-Shao Lin
Wei-Shao Lin
Purpose: To examine the color stability of 3D‐printed and milled, interim, and definitive, restorative materials after immersion in artificial saliva and wine for 1, 3, and 6 months. Material and Methods: The study used a 2 × 5 factorial design with 10 subgroups, including 2 immersion liquids (artificial saliva and wine) and 5 manufacturing technology and restorative material combinations ( n = 10). Color measurements were taken using a contact‐type digital spectrophotometer (CM‐2600d Spectrophotometer; Konica Minolta Healthcare Americas Inc) before immersion and at 1 month (T1), 3 months (T3), and 6 months (T6) after immersion. The CIE2000 system was used to calculate quantitative measurements of color differences in ΔE 00 , and comparisons were made to the acceptability threshold (AT) and perceptibility threshold (PT). Repeated measures of ANOVA ( α = 0.05) were used to compare differences in color changes between manufacturing technology/restorative material‐immersion liquid combinations at T1, T3, and T6. Results: To compare the effect of immersion liquid and time on the manufacturing technology/restorative material groups, the ΔE 00 values were compared to the PT of 0.8 and the AT of 1.8. Wine caused significant color changes in ΔE 00 values beyond the PT and AT values in all groups at all time intervals, except for the AT value of milled definitive crowns (hybrid nano‐ceramic material). Wine immersion caused significant ΔE 00 for all manufacturing technology/restorative material groups at all time intervals (1 month, 3 months, and 6 months) when compared to artificial saliva immersion (all p < 0.001). Conclusion: Upon exposure to artificial saliva, 80%–100% of samples from all groups remained within the acceptable and perceptible color change thresholds. The wine had significant chromogenic effects on all tested restorative materials, however, the milled definitive crowns (hybrid nano‐ceramic material) showed the greatest color stability. For patients with heavy wine consumption, 3D‐printed definitive crowns (hybrid ceramic‐filled material) may show discoloration exceeding acceptable and perceptible color change limits.

3 November 2024 in Journal of Prosthodontics
Verified
Journal Article
Open access
TNToshiki Nagai
Toshiki Nagai
WLWeiqing Liu
Weiqing Liu
CYChao‐Chieh Yang
Chao‐Chieh Yang
WPWaldemar D. Polido
Waldemar D. Polido
DMDean Morton
Dean Morton
Wei-Shao LinWei-Shao Lin
Wei-Shao Lin
Although there are difficulties with using intraoral scans for implant‐supported complete‐arch fixed dental prostheses (ISCFDPs), several commercially available systems have become helpful in simplifying the treatment process in the prosthetic phase. These systems help patients move from interim ISCFDPs to receiving definitive prostheses in just three clinical visits. This clinical report summarizes the indications, benefits, and limitations of the four systems. The information provided in this report about the digital prosthetic workflow of ISCFDPs aims to help clinicians make well‐informed choices and improve treatment results. With digital technologies advancing, refining these tools and protocols, and validating research is crucial for continued evolution in the field.

5 September 2025 in Journal of Prosthodontics
Verified
Journal Article
Open access
WLWeiqing Liu
Weiqing Liu
TNToshiki Nagai
Toshiki Nagai
Wei-Shao LinWei-Shao Lin
Wei-Shao Lin
This clinical report presents a comprehensive digital workflow for rehabilitating a patient with maxillary terminal dentition using a full‐arch, implant‐supported fixed dental prosthesis (FP‐1). It highlights the integration of a 3D‐printed polychromatic flangeless trial denture and a customized anatomic bone reduction template, enabling prosthetically driven implant planning and optimal bone architecture modification. The workflow incorporated fully guided implant surgery using sequential templates and immediate loading with a closed‐mouth pickup system. Intraoral scanning protocols were employed for definitive prosthesis fabrication. This approach addressed high esthetic risks while achieving surgical precision, efficient treatment execution, and favorable clinical outcomes.

6 July 2025 in Journal of Prosthodontics
Verified
Journal Article
Open access
TNToshiki Nagai
Toshiki Nagai
YKYusuke Kuroda
Yusuke Kuroda
NANatalie Asavanant
Natalie Asavanant
CYChao‐Chieh Yang
Chao‐Chieh Yang
DMDean Morton
Dean Morton
Wei-Shao LinWei-Shao Lin
Wei-Shao Lin
Purpose: To evaluate the impact of different complete‐arch digital scanning techniques and prosthesis types on the passive fit of computer‐aided design and computer‐aided manufacturing (CAD‐CAM) verification devices.Materials and Methods: Two different maxillary master casts with four multi‐unit abutment (MUA) implant analogs (FP‐1 and FP‐3 prosthesis types) were used as the basis for fabricating verification devices through two impression techniques (OptiSplint and RevEX). Group 1 utilized digital scans of splinted scanbodies reinforced with a light‐polymerizing acrylic resin and metal mesh on the FP‐1 cast (OptiSplint technique), Group 2 employed the same impression technique as Group 1 on the FP‐3 cast, Group 3 applied digital scans of reverse scanbodies connected to a passively fitting interim prosthesis on FP‐1 cast (RevEX technique), and Group 4 used the same impression technique as Group 3 on FP‐3 cast. A total of 40 milled verification devices were fabricated, with 10 devices allocated to each group. The misfit of verification devices was assessed using visual inspection, tactile sensation, and a one‐screw test, with any disagreements between the two primary examiners resolved by a third evaluator. Agreement between the clinicians was assessed using Cohen's kappa statistics and percent agreement. The percentage of misfits was calculated for each group and compared between groups using Fisher's exact tests (α = 0.05).Results: The misfit analysis showed the lowest misfit (10%) in Group 1 (OptiSplint‐FP1), followed by Groups 3 (RevEX‐FP1) and 4 (RevEX‐FP3) at 20%, and the highest (40%) in Group 2 (OptiSplint‐FP3), with no significant differences between groups by Fisher's exact tests (p > 0.05). Odds ratios indicated six times higher misfit odds for FP‐3 than FP‐1 with OptiSplint, no difference for FP‐1 versus FP‐3 with RevEX (odds ratio = 1.0), and lower odds with RevEX compared to OptiSplint under FP‐3 conditions (odds ratio = 0.375). Inter‐examiner agreement was strong, with 90% concordance and a Kappa statistic of 0.66, demonstrating substantial consistency.Conclusion: OptiSplint is preferable for FP1 cases, whereas RevEX suits FP3 cases when intraoral–scanner–based extraoral workflows are used. Despite these recommendations, misfits occurred in every group, suggesting that a verification cast may be prudent when adopting these newer scanning approaches. Clinicians should consider fabricating an additional verification cast with splinted scanbodies or a clinically satisfactory interim implant prosthesis. This cast can confirm implant positions whenever modern scanbodies such as OptiSplint or RevEX are incorporated into the workflow.

20 May 2025 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
TNToshiki Nagai
Toshiki Nagai
AAAmal Alfaraj
Amal Alfaraj
Wei-Shao LinWei-Shao Lin
Wei-Shao Lin
Objectives: To examine the effects of surface treatments on the color stability, surface roughness, surface gloss, and wettability of monolithic polychromatic material jetting (MJT) 3D-printed denture material. Material and Methods: Twenty-one color variants of the same denture material (TrueDent; Stratasys, Eden, MN, USA) underwent two surface treatments (polishing only or polishing and glazing), creating 42 study groups with a total of 420 samples (n = 10 per group). The samples were manufactured using a PolyJet 3D printer (J5 DentaJet; Stratasys, Eden, MN, USA), a type of MJT 3D printer. Color measurements were taken with a digital spectrophotometer before and after the surface treatments, and quantitative color differences (ΔE00 and ΔC*) were calculated using the CIE2000 system. Comparisons of ΔE00 were made against the 50%:50% acceptability threshold (AT) of 1.8 and the 50%:50% perceptibility threshold (PT) of 0.8 for tooth shade, as well as the 50%:50% PT of 1.72 and the 50%:50% AT of 4.08 for gingival (pink) shade. After surface treatment, the gloss was measured using a glossmeter, surface roughness was measured with optical profilometry, and wettability was measured by contact angle measurements using an optical tensiometer. The significance of surface treatment on color changes for each color variant was evaluated using one-sided, one-sample t-tests against the AT and PT. The effects of surface treatment on surface gloss, surface roughness, contact angle, and ΔC* were analyzed using t-tests for each color variant. Pairwise comparisons between groups were made using Fisher’s Protected Least Significant Differences (α = 0.05). Results: In most cases, glazing caused the color change (ΔE00) to exceed the AT and PT, with a few exceptions. Most materials exhibited a more vibrant (more saturated) appearance and statistically higher chroma, with glazed surface treatments compared to polished ones, though there were some exceptions. For all materials, the glazed samples had significantly higher gloss units than the polished ones (p < 0.0001). Additionally, all materials showed significantly higher surface roughness in glazed samples compared to polished ones (p < 0.0001 for most). The polished samples had significantly higher contact angles (p < 0.0001 for most). Conclusions: Surface treatments significantly influenced the color, surface gloss, surface roughness, and wettability of MJT 3D-printed denture materials. Glazing led to increased chroma and gloss and produced more hydrophilic surfaces, although it also increased surface roughness. These results highlight the importance of surface treatment selection in optimizing the clinical performance of MJT-fabricated dentures.