Binh Thuc Tran

Dr. Binh Thuc Tran

Hue University, Huế, Thừa Thiên-Huế, Vietnam

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2022 in Molecules
Verified
Journal Article
Open access
PDF file
BTBinh Thuc Tran
Binh Thuc Tran
TTTuyen Ngoc Tran
Tuyen Ngoc Tran
TMTran Thi Ai My
Tran Thi Ai My
CGChau Nguyen Dang Giang
Chau Nguyen Dang Giang
QNQuynh Trang Thi Nguyen
Quynh Trang Thi Nguyen
In this paper, the classical least-squares (CLS) method with molecular absorption spectrophotometric measurement was used to determine simultaneously paracetamol (PAR), ibuprofen (IBU), and caffeine (CAF) in tablets. The absorbance spectra of the standard solutions and samples were measured over a wavelength from 220 to 300 nm with a 0.5 nm step. The concentration of PAR, IBU, and CAF in the sample solutions was calculated by using Visual Basic for Applications (VBA) and a program called CLS-Excel written in Microsoft Excel 2016. The method and the CLS-Excel program were tested on mixed standard laboratory samples with different PAR, IBU, and CAF concentration ratios, and they showed only small errors and a satisfying repeatability. An analytical procedure for tablets containing PAR, IBU, and CAF was developed. The reliability of the procedure was proved via the recovery and repeatability of the analysis results with an actual tablet sample and by comparing the mean contents of active substances in the tablets obtained from the analytical procedure with the HPLC method. The procedure is simple with a reduced cost compared with the HPLC standard method.

1 April 2019 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
NTNguyen Thi Quynh Trang
Nguyen Thi Quynh Trang
NHNguyen Van Hop
Nguyen Van Hop
NCNguyen Dang Giang Chau
Nguyen Dang Giang Chau
BTBinh Thuc Tran
Binh Thuc Tran
In this work, a new solution has been found for selecting the approximate initial value of concentration (by means of the classical least squares) and variance (calculated by the Horwitz equation) for the Kalman filter algorithm. With this solution, the Kalman method is less error-prone and has a better repeatability than the least squares method when using the full spectrum. A protocol for simultaneous determination of amlodipine (AML), hydrochlorothiazide (HYD), and valsartan (VAL) in pharmaceutical products was developed based on the spectrophotometry-chemometric method using full spectrum measurement in combination with the Kalman filter algorithm written in Microsoft Excel 2016 and Visual Basic for Applications (VBA). The method was validated on the Exforge HCT tablets with good repeatability (RSD) (varied from 2.2% to 2.3% (n = 3) for all the three studied compounds) and good recovery (90.0%–94.0% for AML, 90.3%–94.5% for HYD, and 98.5%–103.1% for VAL (n = 3)). The results were in good agreement with the measurements achieved from the high-performance liquid chromatography (HPLC) method.

20 July 2021 in Journal of Analytical Methods in Chemistry
Verified
Journal Article
Open access
PDF file
BTBinh Thuc Tran
Binh Thuc Tran
LTLe Thi Phuong Tram
Le Thi Phuong Tram
NHNguyen Van Hop
Nguyen Van Hop
CGChau Nguyen Dang Giang
Chau Nguyen Dang Giang
NLNguyen Duy Luu
Nguyen Duy Luu
NTNguyen Thi Quynh Trang
Nguyen Thi Quynh Trang
In this paper, hydrochlorothiazide (HCT) and losartan potassium (LSP) in tablets are simultaneously determined with UV-Vis spectrophotometry and chemometrics without separation. The spectra of standard and sample solutions were recorded in the wavelength from 220 to 300 nm at 1.0 nm intervals. The concentrations of HCT and LSP in the sample solutions were computed with the Kalman filter algorithm written on the Microsoft Excel 2016 and Visual Basic for Applications (VBA) platform. The method validation was determined via the accuracy and repeatability of measurements when analyzing HCT and LSP in the Splozarsin Plus tablet and comparing the mean values of their contents in the sample with those analyzed with HPLC. The proposed method is simple with a low cost compared with the standard HPLC method.

29 May 2023 in MOJ Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
NLNguyen Duy Luu
Nguyen Duy Luu
TDTran Duong Duy
Tran Duong Duy
BTBinh Thuc Tran
Binh Thuc Tran
In this article, a combined method of molecular absorption spectroscopy and classical least squares is used to simultaneously determine paracetamol (PAR) and codeine phosphate (COP) in pharmaceutical samples without the need for prior separation or extraction steps. The absorption spectra of standard solutions and samples were measured in the wavelength range of 210 to 290 nm with a step size of 0.5 nm. The concentrations of PAR and COP in the sample solutions were calculated using a self-made program written in Microsoft Excel 2016 and Visual Basic for Applications (VBA). The reliability of the method was verified through the accuracy and reproducibility of the measurements when analyzing PAR and COP in Effer-Paralmax® Codeine tablets, and comparing the average values of their concentrations in the samples with the standard HPLC method.

22 March 2022 in Preprints.org
Verified
Preprint
Open access
PDF file
BTBinh Thuc Tran
Binh Thuc Tran
TTTuyen Ngoc Tran
Tuyen Ngoc Tran
TMTran Thi Ai My
Tran Thi Ai My
CGChau Nguyen Dang Giang
Chau Nguyen Dang Giang
QNQuynh Trang Thi Nguyen
Quynh Trang Thi Nguyen
In this paper, the classical least square (CLS) method with molecular absorption spectrophotometric measurement was used to determine simultaneously of paracetamol (PAR), ibuprofen (IBU), and caffeine (CAF) in tablets. The absorbance spectra of the standard solutions and samples were measured over a wavelength from 220 to 300 nm with a 0.5 nm step. The concentration of PAR, IBU and CAF in the sample solutions were calculated by using a program called CLS-Excel written in Microsoft Excel 2016 and Visual Basic for Applications (VBA). The method and CLS-Excel program were tested on mixed standard laboratory samples with different PAR, IBU, and CAF concentration ratios, and they showed small errors and satisfying repeatability. An analytical procedure for tablets containing PAR, IBU, and CAF was developed. The reliability of the procedure was proved via the recovery and repeatability of the analysis results with an actual tablet sample and comparing the mean contents of active substances in the tablets obtained from the analytical procedure with the from the HPLC method. The procedure is simple with a reduced cost compared with the HPLC standard method.

1 June 2025 in Journal of Analytical Chemistry
Verified
Journal Article
Closed access
PDF file
NDNguyen Hung Nhat Duy
Nguyen Hung Nhat Duy
PQPham Phu Quoc
Pham Phu Quoc
NKNguyen The Khang
Nguyen The Khang
LHLe Thanh Huyen
Le Thanh Huyen
NLNguyen Dinh Luyen
Nguyen Dinh Luyen
BTBinh Thuc Tran
Binh Thuc Tran
The accurate quantification of analytes in samples with overlapping spectra remains a critical challenge in analytical chemistry, particularly for complex pharmaceutical formulations. Developing a method for simultaneous quantification of metronidazole (MTZ) and spiramycin (SPI) that is rapid, accurate, reliable, and cost-effective is imperative. This study aims to apply an ultraviolet-visible (UV-Vis) method integrating wavelength selection algorithms with partial least squares (PLS) regression for the simultaneous quantification of MTZ and SPI in tablets. Concurrently, it clarifies the steps to compute the limit of detection range, specifically the minimum and maximum values, in PLS methods. UV-Vis spectra of MTZ and SPI mixtures in standard concentration sets were scanned from 200–400 nm with a scan interval of 0.5 nm. The backward variable elimination–partial least square (BVE-PLS), and genetic algorithm–partial least square (GA-PLS) methods were employed for optimal wavelength selection. Analyte concentrations were computed via PLS methods using acquired spectral data. Multivariate regression models were evaluated via statistical parameters: the coefficient of determination (R2), root mean square error, and residual analysis. Methods were assessed following Association of Official Analytical Chemists guidelines. The results demonstrate that the BVE-PLS and GA-PLS wavelength selection methods produced superior computational outcomes compared to full spectral data PLS methods. Ultimately, simultaneous quantification methods for MTZ and SPI were successfully developed, validated, and shown to be accurate, straightforward, rapid, cost-effective, and stable.