Tyler Capek

Mr. Tyler Capek

Michigan Technological University
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2018 in Environmental Science & Technology Letters
Verified
Journal Article
Closed access
GGGiulia Girotto
Giulia Girotto
Swarup ChinaSwarup China
Swarup China
JBJanarjan Bhandari
Janarjan Bhandari
KGKyle Gorkowski
Kyle Gorkowski
BSBarbara V. Scarnato
Barbara V. Scarnato
CMClaudio Mazzoleni
Claudio Mazzoleni

25 June 2025 in Journal of Power Sources
Verified
Journal Article
Closed access
YCYuyao Cao
Yuyao Cao
YPYa Peng
Ya Peng
ZTZhenxiang Tao
Zhenxiang Tao
RYRui Yang
Rui Yang
WLWeina Li
Weina Li
HZHui Zhang
Hui Zhang

23 March 2021 in Aerosol Science and Technology
Verified
Journal Article
Closed access
CCChristian M. Carrico
Christian M. Carrico
Tyler CapekTyler Capek
Tyler Capek
KGKyle Gorkowski
Kyle Gorkowski
JLJared T. Lam
Jared T. Lam
SGSabina Gulick
Sabina Gulick
MDManvendra Dubey
Manvendra Dubey
We report the development and validation of a new humidified aerosol single-scattering albedometer to quantify the effects of water uptake on submicrometer particle optical properties. The instrument simultaneously measures in situ aerosol light extinction (σep) and scattering (σsp) using a cavity-attenuated phase shift-single scattering albedo particulate matter (PM) monitor (CAPS-PMSSA, Aerodyne Research, Inc., Billerica, MA, USA). It retrieves by difference aerosol light absorption (σap) and directly quantifies aerosol single-scattering albedo (SSA), the aerosol “brightness.” We custom built a relative humidity (RH) control system using a water vapor-permeable membrane humidifier and coupled it to the CAPS-PMSSA to enable humidified aerosol observations. Our humidified instrument (H-CAPS-PMSSA) overcomes problems with noise caused by mirror purge-flow humidification, heating, and characterizing cell RH. Careful angular truncation corrections in scattering, particularly for larger particles, were combined with empirical observations. Results show that the optimal operational size to be Dp < 400 nm. The H-CAPS-PMSSA was evaluated with several pure single-component aerosols including ammonium sulfate ((NH4)2SO4), absorbing nigrosin, and levoglucosan, an organic biomass smoke tracer. The measured σep, σsp, and the derived optical hygroscopicity parameter (κ) for size-selected ammonium sulfate are in good agreement with literature values. For dry size-selected nigrosin in the 100 < Dp < 400 nm range, SSA values increased from ∼0.3 to 0.65 with increasing Dp. The enhancement in nigrosin σap at RH = 80% was a factor of 1.05–1.20 relative to dry conditions, with the larger particles showing greater enhancement. SSA increased with RH with the largest fractional enhancement measured for the smallest particles. For polydisperse levoglucosan, we measured an optical κ of 0.26 for both light extinction and scattering and negligible absorption. Our new instrument enables reliable observations of the effects of ambient humidity on mixed aerosol optical properties, particularly for light-absorbing aerosols whose climate forcing is uncertain due to measurement gaps. Copyright © 2021 American Association for Aerosol Research

26 May 2020 in Aerosol Science and Technology
Verified
Journal Article
Closed access
ASAiswarya Saseendran
Aiswarya Saseendran
SMSusan Mathai
Susan Mathai
SJShreya Joshi
Shreya Joshi
APAnoop Pakkattil
Anoop Pakkattil
Tyler CapekTyler Capek
Tyler Capek
RVRavi Varma
Ravi Varma
Atmospheric Aerosols affect Earth’s climate directly by scattering and absorbing solar radiation. In order to study the optical properties of aerosols, we developed a broadband cavity-enhanced spectrometer that uses a supercontinuum laser source and a compact spectrometer, to measure simultaneously the extinction coefficient of aerosols over a broad wavelength region from 420-540 nm. The system employs a dual cavity approach with a reference and a sample cavity, accounting for changes in gases background and for laser spectral and intensity fluctuations. We tested the system with aerosolized salt particles and polystyrene latex spheres. We performed calculations using Mie theory and found good agreement with the measured extinction. We also found that the extinction coefficient of non-absorbing aerosol favorably compares with the scattering coefficient measured by a nephelometer. Finally, we generated soot particles and found an extinction Ångström exponent in good agreement with values reported in the literature. Wavelength dependent detection limits (1σ) for the instrument at 5 nm wavelength resolution and for an integration time of ∼10 minutes were found to be in the range ∼5 Mm−1 – 13 Mm−1. The broadband dual-cavity extinction spectrometer is simple and robust and might be particularly useful for laboratory measurements of the extinction coefficient of brown carbon aerosol. The laboratory tests suggest that the prototype is promising for future developments of a field-deployable instrument.

17 December 2020 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Tyler CapekTyler Capek
Tyler Capek
JBJacek Borysow
Jacek Borysow
CMClaudio Mazzoleni
Claudio Mazzoleni
MMMassimo Moraldi
Massimo Moraldi
We demonstrate precise determination of atmospheric temperature using vibro-rotational Raman (VRR) spectra of molecular nitrogen and oxygen in the range of 292–293 K. We used a continuous wave fiber laser operating at 10 W near 532 nm as an excitation source in conjunction with a multi-pass cell. First, we show that the approximation that nitrogen and oxygen molecules behave like rigid rotors leads to erroneous derivations of temperature values from VRR spectra. Then, we account for molecular non-rigidity and compare four different methods for the determination of air temperature. Each method requires no temperature calibration. The first method involves fitting the intensity of individual lines within the same branch to their respective transition energies. We also infer temperature by taking ratios of two isolated VRR lines; first from two lines of the same branch, and then one line from the S-branch and one from the O-branch. Finally, we take ratios of groups of lines. Comparing these methods, we found that a precision up to 0.1 K is possible. In the case of O2, a comparison between the different methods show that the inferred temperature was self-consistent to within 1 K. The temperature inferred from N2 differed by as much as 3 K depending on which VRR branch was used. Here we discuss the advantages and disadvantages of each method. Our methods can be extended to the development of instrumentation capable of non-invasive monitoring of gas temperature with broad potential applications, for example, in laboratory, ground-based, or airborne remote sensing.

11 September 2019 in Molecular Physics
Verified
Journal Article
Closed access
JBJacek Borysow
Jacek Borysow
Tyler CapekTyler Capek
Tyler Capek
CMClaudio Mazzoleni
Claudio Mazzoleni
MMMassimo Moraldi
Massimo Moraldi
We present new, highly accurate, measurements of the fundamental band of the roto-vibrational Raman spectrum of molecular nitrogen and oxygen. Experimentally obtained spectra were used as a basis to derive information about the anisotropy of the polarisability tensor, including its dependence on rotational state due to molecular non-rigidity. Third-order perturbative calculations were used to determine corrections to the Raman scattering cross sections as a function of the rotational quantum numbers. Our results for the ratio of polarisability anisotropy at equilibrium divided by its first derivative for nitrogen are in agreement with values reported previously and are significantly different from historical data obtained for oxygen. GRAPHICAL ABSTRACT