Ufuk Perişanoğlu

Dr. Ufuk Perişanoğlu

Materials Science and Engineering, Hakkari University, Hakkari, Hakkâri, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Progress in Nuclear Energy
Verified
Journal Article
Closed access
EKEsra Kavaz
Esra Kavaz
NEN. Ekinci
N. Ekinci
Huseyin Ozan TekinHuseyin Ozan Tekin
Huseyin Ozan Tekin
MSM.I. Sayyed
M.I. Sayyed
BABünyamin Aygün
Bünyamin Aygün
UPUfuk Perişanoğlu
Ufuk Perişanoğlu

1 February 2020 in Ceramics International
Verified
Journal Article
Closed access
UPUfuk Perişanoğlu
Ufuk Perişanoğlu
FEF.I. El-Agawany
F.I. El-Agawany
EKEsra Kavaz
Esra Kavaz
MAM. Al-Buriahi
M. Al-Buriahi
YRY.S. Rammah
Y.S. Rammah

13 November 2019 in Applied Physics A
Verified
Journal Article
Closed access
PDF file
FEF. I. El-Agawany
F. I. El-Agawany
EKEsra Kavaz
Esra Kavaz
UPUfuk Perişanoğlu
Ufuk Perişanoğlu
MAM. Al-Buriahi
M. Al-Buriahi
YRY. S. Rammah
Y. S. Rammah

25 March 2019 in Radiation Effects and Defects in Solids
Verified
Journal Article
Closed access
NENeslihan Ekinci
Neslihan Ekinci
EKEsra Kavaz
Esra Kavaz
BABünyamin Aygün
Bünyamin Aygün
UPUfuk Perişanoğlu
Ufuk Perişanoğlu
Because of the high radiation dose in applications involving nuclear reactors, medical treatments etc., it is important to reduce the exposure to radiation of areas and workers. In this study, we were examined gamma ray shielding parameters of the newly produced Re-based superalloys. Mass attenuation coefficient (µ/ρ) of the alloys were obtained experimentally at 81, 276, 302, 356, 383 keV photon energies emitted from 133Ba radioactive source using Ultra Ge detector. The experimental results were compared with the values obtained by the WinXCOM program and were found to be in perfect agreement with each other. Additionally, effective atomic number (Zeff) and electron density (Neff) were determined for produced Rhenium (Re) based super alloys in the energy range 1 keV–100 GeV. S5 sample which has maximum Rhenium percentage own the largest µ/ρ and Zeff values. Moreover, by using Geometric Progression (GP) approximation, EABF and EBF were computed for the superalloys depending on the energy and penetration depths. It has been deduced that the values of EABF and EBF are minimum in the medium energy region. EBF and EABF values of the alloys have changed depending on the equivalent atomic number. Among alloy samples under study, S5 superalloy is the best for gamma ray shielding. However, in general, considering the radiation energies used in many applications, all the alloys under study have satisfactory radiation absorption properties.

30 May 2020 in Applied Physics A
Verified
Journal Article
Closed access
PDF file
UPUfuk Perişanoğlu
Ufuk Perişanoğlu
EKEsra Kavaz
Esra Kavaz
HTH. O. Tekin
H. O. Tekin
SAS. R. Armoosh
S. R. Armoosh
NEN. Ekinci
N. Ekinci
MOM. Oltulu
M. Oltulu