Vanesa Bochkezanian

Dr. Vanesa Bochkezanian

School of Public Health, University of Adelaide, Adelaide, South Australia, Australia
orcid
Senior Research Fellow Implementation Science JBI-Adelaide U...

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2019 in American Journal of Physical Medicine & Rehabilitation
Verified
Journal Article
Closed access
ABAmira Hassan Bekhet
Amira Hassan Bekhet
Vanesa BochkezanianVanesa Bochkezanian
Vanesa Bochkezanian
ISIbtissam M. Saab
Ibtissam M. Saab
Ashraf S. S GorgeyAshraf S. S Gorgey
Ashraf S. S Gorgey
Controversial findings about the effects of neuromuscular electrical stimulation and functional electrical stimulation in managing spasticity have been raised after spinal cord injury. A systematic review was conducted to identify the range of the stimulation parameters that may alleviate spasticity. Three independent reviewers searched Medline (PubMed), web of knowledge, Scopus, Cochrane Central, Virtual Health Library, and Physiotherapy Evidence Database until January 2018. Inclusion criteria were applications of neuromuscular electrical stimulation/functional electrical stimulation on the lower limb muscles, stimulation parameters (frequency, pulse duration, and amplitude of current), and measures of spasticity after spinal cord injury. The primary outcome was spasticity as measured by the Modified Ashworth Scale and the secondary outcome was spasticity assessed by other indirect measures. Twenty-three clinical and nonclinical trials were included with 389 subjects. Neuromuscular electrical stimulation/functional electrical stimulation provided reductions in spasticity by 45%–60% with decrease in electromyography activity and increase in range of motion after spinal cord injury. The identified stimulation parameters were frequency of 20–30 Hz, pulse duration of 300–350 μs, and amplitude of the current greater than 100 mA. Neuromuscular electrical stimulation/functional electrical stimulation provides an effective rehabilitation strategy in managing spasticity. However, a recommendation of the stimulation parameters cannot be accurately assumed because of high variability in the methodology, design, and heterogeneity of the included studies.

30 June 2022 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
LCLucas Cardoso
Lucas Cardoso
Vanesa BochkezanianVanesa Bochkezanian
Vanesa Bochkezanian
AFArturo Forner-Cordero
Arturo Forner-Cordero
AMAlejandro Melendez-Calderon
Alejandro Melendez-Calderon
ABAntonio Padilha Lanari Bo
Antonio Padilha Lanari Bo
Background: Recovery of hand function is crucial for the independence of people with spinal cord injury (SCI). Wearable devices based on soft robotics (SR) or functional electrical stimulation (FES) have been employed to assist the recovery of hand function both during activities of daily living (ADLs) and during therapy. However, the implementation of these wearable devices has not been compiled in a review focusing on the functional outcomes they can activate/elicit/stimulate/potentiate. This narrative review aims at providing a guide both for engineers to help in the development of new technologies and for clinicians to serve as clinical guidelines based on the available technology in order to assist and/or recover hand function in people with SCI. Methods: A literature search was performed in Scopus, Pubmed and IEEE Xplore for articles involving SR devices or FES systems designed for hand therapy or assistance, published since 2010. Only studies that reported functional outcomes from individuals with SCI were selected. The final collections of both groups (SR and FES) were analysed based on the technical aspects and reported functional outcomes. Results: A total of 37 out of 1101 articles were selected, 12 regarding SR and 25 involving FES devices. Most studies were limited to research prototypes, designed either for assistance or therapy. From an engineering perspective, technological improvements for home-based use such as portability, donning/doffing and the time spent with calibration were identified. From the clinician point of view, the most suitable technical features (e.g., user intent detection) and assessment tools should be determined according to the particular patient condition. A wide range of functional assessment tests were adopted, moreover, most studies used non-standardized tests. Conclusion: SR and FES wearable devices are promising technologies to support hand function recovery in subjects with SCI. Technical improvements in aspects such as the user intent detection, portability or calibration as well as consistent assessment of functional outcomes were the main identified limitations. These limitations seem to be be preventing the translation into clinical practice of these technological devices created in the laboratory.

1 September 2018 in Medicine & Science in Sports & Exercise
Verified
Journal Article
Closed access
Vanesa BochkezanianVanesa Bochkezanian
Vanesa Bochkezanian
RNRobert U. Newton
Robert U. Newton
GTGabriel S. Trajano
Gabriel S. Trajano
Anthony BlazevichAnthony Blazevich
Anthony Blazevich
Introduction: Muscle force production is usually impaired in people with spinal cord injury (SCI). The use of high-intensity neuromuscular electrical stimulation (NMES) strength training can help promote metabolically active lean muscle mass and, thus, increase muscle mass and improve physical health and quality of life (QoL). Nonetheless, NMES is usually used at low-stimulation intensities, and there is limited evidence on the effects of high-intensity NMES strength training into improving muscle force and mass, symptoms of spasticity, or physical health and QoL in people with SCI. Methods: Five individuals with chronic SCI completed five 10-repetition sets of high-intensity knee extension NMES strength training sessions for 12 wk in both quadriceps muscles. Quadriceps femoris (QF) knee extensor torque was measured on a dynamometer, and cross-sectional area (CSAQF) was measured with extended field-of-view ultrasonography. Venous blood samples were collected for blood lipid profiling and C-reactive protein analyses. The Spinal Cord Injury Spasticity Evaluation Tool was used to assess symptoms of spasticity, and the QoL index SCI version III was used for QoL measures. Results: QF tetanic knee extensor torque increased on average by 35% (2%–92%), and CSAQF increased by 47% (14%–145%). A significant increase in the HDL/LDL cholesterol ratio (P < 0.001) and a mean significant improvement of 4.8% ± 2.3% (absolute value = 0.26) in the Spinal Cord Injury Spasticity Evaluation Tool score was observed, whereas QoL showed a near-significant improvement in the health and functioning domain (15.0 ± 4.2 and 17.3 ± 5.1; P = 0.07). Conclusions: High-intensity NMES strength training in people with SCI may improve muscle strength, mass, physical health, and QoL. However, replication of these results is necessary before clinical implementation.

31 March 2015 in Spinal Cord
Verified
Journal Article
Open access
PDF file
Vanesa BochkezanianVanesa Bochkezanian
Vanesa Bochkezanian
JRJ Raymond
J Raymond
COCamila Quel de Oliveira
Camila Quel de Oliveira
GDG M Davis
G M Davis
Study design: A systematic review. Objectives: The aim of this systematic review was to establish whether combined aerobic training and muscle strength training is effective in improving aerobic fitness, muscle strength, function and/or quality of life (QoL) in people with spinal cord injury (SCI). Settings: Faculty of Health Sciences. University of Sydney, NSW, Australia. Methods: A search was conducted for randomized controlled trials (RCTs), controlled trials, uncontrolled clinical trials, case series and cross-over studies involving exercise interventions that included a combination of aerobic and strength components, either in circuit-mode or in sequence for people with SCI. Methodological quality was independently rated using the PEDro scale and key findings were extracted from trials by two reviewers. Results: The search identified 7981 abstracts, from which nine trials met the inclusion criteria. From the nine selected trials, seven reported aerobic outcomes, two of which showed a statistically significant within-group difference in aerobic fitness. Five studies reported muscle strength outcomes, four of them showed a statistically significant within-group mean difference on at least one outcome measure. Two studies looked at QoL, one of them found a statistically significant between-group difference on one outcome measure. Conclusion: Our systematic review showed that literature on SCI population is scarce, of low quality and findings of existing studies are inconsistent. Thus, further RCTs with larger number of participants are needed to make a definite conclusion about the influence of combined aerobic and muscle strength training on aerobic fitness, muscle strength and QoL in people with SCI.

1 June 2022 in Archives of Physical Medicine and Rehabilitation
Verified
Journal Article
Closed access
ABAmira Hassan Bekhet
Amira Hassan Bekhet
AJAlhadi M. Jahan
Alhadi M. Jahan
Vanesa BochkezanianVanesa Bochkezanian
Vanesa Bochkezanian
KMKristin E. Musselman
Kristin E. Musselman
AEAmr A. Elsareih
Amr A. Elsareih
Ashraf S. S GorgeyAshraf S. S Gorgey
Ashraf S. S Gorgey

23 December 2025 in JBI Evidence Implementation
Verified
Journal Article
Closed access
MLMatthew J. Leach
Matthew J. Leach
Vanesa BochkezanianVanesa Bochkezanian
Vanesa Bochkezanian
AMAlexa McArthur
Alexa McArthur
DCDaniela Cardoso
Daniela Cardoso
FUFrazer Underwood
Frazer Underwood
CLCraig Lockwood
Craig Lockwood
Introduction: Although health care agencies are encouraged to use quality improvement (QI) initiatives to improve quality of care, the ethical integrity of such initiatives has received little attention. Objective: This project aimed to develop and evaluate key criteria to operationalize the Assessment of the Ethical Integrity of QI Studies (AEGIS). Methods: The study used a four-phase sequential mixed methods design, comprising (i) a systematic mapping study to identify [Phase I] and map [Phase II] preliminary criteria against international ethical guidelines; (ii) an e-Delphi study to reach consensus on the transformed AEGIS criteria [Phase III]; and (iii) a psychometric evaluation to assess the utility and reliability of the AEGIS criteria [Phase IV]. Results: Phase I identified 23 preliminary AEGIS criteria, which were mapped against 18 ethical guidelines/statements [Phase II]. No statements were mapped to the five levels of ethical review; 0%–61.5% were mapped to four criteria for ethical review exemption; 15.4%–30.8% were mapped to seven triggers for ethical review; and 69.2%–100% were mapped to seven ethical principles. Preliminary criteria were transformed into 18 criteria, with a Delphi panel reaching > 70% consensus on all criteria [Phase III]. A panel of international experts tested the AEGIS tool against five randomly selected publications of QI activities [Phase IV], demonstrating that the tool had good internal consistency (α = 0.734), moderate interrater reliability (κ = 0.481), and good utility. Conclusions: The 18-item AEGIS tool demonstrated excellent face and content validity, good internal consistency and utility, moderate interrater reliability, and broad application and international relevance. Thus, the AEGIS tool represents an important step toward improving the ethical conduct and integrity of QI projects. Spanish http://links.lww.com/IJEBH/A451