Load frequency control (LFC) plays a critical role in maintaining the stability and reliability of the power system. With the increasing integration of renewable energy sources and the growth of complex interconnected grids, efficient and robust LFC strategies are in high demand. In recent years, the combination of particle swarm optimisation (PSO) and proportional-integral-derivative (PID) controllers, known as PSP-PID, has been used as a promising approach to enhance the performance of LFC systems. This article focuses on modelling, simulation, optimisation, advanced control techniques, expert knowledge, and iterative refinement of the power system to help achieve suitable PID settings that provide reliable control of the load frequency in the transmission line. The performance indices of the proposed algorithm are measured by the integral time absolute error (ITAE), which is 0.0005757 with 0.9994 Ki, 0.7741 Kp, and 0.1850 Kd. The model system dynamics are tested by varying the load frequency from 300 MW to 350 MW at a load variation of 0.2. The suggested controller algorithm is relatively reliable and accurate in power system management and protection load frequency control compared to conventional methods. This work can be improved by including more generating stations synchronised into a single network.

5 July 2022 in Signals
Verified
Journal Article
Open access
PDF file
VOVINCENT NSED OGAR
VINCENT NSED OGAR
Sajjad HussainSajjad Hussain
Sajjad Hussain
Kelum A.A. GamageKelum A.A. Gamage
Kelum A.A. Gamage
Transmission line fault classification forms the basis of fault protection management in power systems. Because faults have adverse effects on transmission lines, adequate measures must be implemented to avoid power outages. This paper focuses on using the categorical boosting (CatBoost) algorithm classifier to analyse and train multiple voltage and current data from a 330 kV and 500 km-long simulated faulty transmission line model designed using Matlab/Simulink. From it, 93,340 fault data sizes were extracted. The CatBoost classifier was employed to classify the faults after different machine learning algorithms were used to train the same data with different parameters. The trainer achieved the best accuracy of 99.54%, with an error of 0.46% for 748 iterations out of 1000. The algorithm was selected for its high performance in classifying faults based on accuracy, precision and speed. In addition, it is easy to use and handles multiple data-sets. In contrast, a support vector machine and an artificial neural network each has a longer training time than the proposed method’s 58.5 s. Proper fault classification techniques assist in the effective fault management and planning of power system control thereby preventing energy waste and providing high performance.

2 February 2023 in Heliyon
Verified
Journal Article
Open access
VOVINCENT NSED OGAR
VINCENT NSED OGAR
SHSajjad Hussain
Sajjad Hussain
KGKelum A.A. Gamage
Kelum A.A. Gamage
One of the most critical concerns in power system reliability is the timely and accurate detection of transmission line faults. Therefore, accurate detection and localisation of these faults are necessary to avert system collapse. This paper focuses on using Artificial Neural Networks in faults detection and localisation to attain accuracy, precision and speed of execution. A 330 kV, 500 km three-phase transmission line was modelled to extract faulty current and voltage data from the line. The Artificial Neural Network technique was used to train this data, and an accuracy of 100% was attained for fault detection and about 99.5% for fault localisation at different distances with 0.0017 μs of detection and an average error of 0%-0.5%. This model performs better than Support Vector Machine and Principal Component Analysis with a higher fault detection time. This proposed model serves as the basis for transmission line fault protection and management system.

1 November 2017
Verified
Conference Paper
Closed access
VOVINCENT NSED OGAR
VINCENT NSED OGAR
DAD. N. Abara
D. N. Abara
EAE. J. Akpama
E. J. Akpama
When a short-circuit occurs in a power system, the magnitude of the fault currents, which is very high compared to the steady state current that flows in the power system, is determined by the reactance of the power system equipment (and the reactance of the ground if ground is involved). It is essential that symmetrical and unsymmetrical analysis of the power system network be undertaken to determine the magnitude of these fault currents and fault MVA (Megavolt-Ampere) so as to select adequate ratings of the power system protective devices - such as circuit breakers, relays and fuses. Otherwise, these protective devices will not operate properly in the event of faults thereby causing considerable damage to life and equipment. In this paper, the Nigeria 330KV network, 32 bus system is considered using relevant data which was obtained from the Nigerian National Integrated Power Project (NIPP) inhouse Grid Study Team Report, and the Transmission Company of Nigeria (TCN). Power System toolbox in MATLAB was used to carry out the simulation analysis. Fault impedance was set to j*0.1, and the various kinds of faults were simulated at bus 32 (Calabar) and bus 6 (Ayede). Base MVA of 100 MVA and Base KV of 330 KV were used. The results obtained show that symmetrical three phase fault is the most severe kind at the transmission lines, while for faults occurring very close to the generating station or synchronous generator, single line to ground fault is the most severe.

1 June 2022 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
VOVINCENT NSED OGAR
VINCENT NSED OGAR
KGKelum A. A. Gamage
Kelum A. A. Gamage
SHSadjjad Hussain
Sadjjad Hussain
The transmission line is an integral part of the electrical power system; however, a fault has a negative impact on the system, like blackout, power loss, financial losses, and socio-economic impact. This fault occurs due to ageing conductors, lightning stroke, switching surge and human interference. We reviewed the protection scheme implemented in the Nigerian transmission network, which has challenges relating to the environment's terrain and a long-distance transmission line of about 20,000 km. The different approach of fault classification, detection and location was analysed and critically summarised. This review paper proposes a hybrid Artificial Neural Network and distance protection scheme that can automatically identify, locate, isolate, predict, correct faults, and real-time monitor and control the entire network. It can also detect the shortest possible trip time of 0.02 s and 0.03 s of line current and fault losses, respectively, during fault to avert damage on the line. However, this method has its challenges, such as the volume of data generated from load flow analysis, training time, and the total distance covered by the network. However, these can be averted by segmenting the entire network for easy evaluation and monitoring to achieve set goals.

7 February 2023 in Signals
Verified
Journal Article
Open access
PDF file
VOVINCENT NSED OGAR
VINCENT NSED OGAR
Sajjad HussainSajjad Hussain
Sajjad Hussain
Kelum A.A. GamageKelum A.A. Gamage
Kelum A.A. Gamage
When a fault occurs on the transmission line, the relay should send the faulty signal to the circuit breaker to trip or isolate the line. Timely detection is integral to fault protection and the management of transmission lines in power systems. This paper focuses on using the threshold current and voltage to reduce the time of delay and trip time of the instantaneous overcurrent relay protection for a 330 kV transmission line. The wavelet transforms toolbox from MATLAB and a Simulink model were used to design the model to detect the threshold value and the coordination time for the backup relay to trip if the primary relay did not operate or clear the fault on time. The difference between the proposed model and the model without the threshold value was analysed. The simulated result shows that the trip time of the two relays demonstrates a fast and precise trip time of 60% to 99.87% compared to other techniques used without the threshold values. The proposed model can eliminate the trial-and-error in programming the instantaneous overcurrent relay setting for optimal performance.