Vincenzo Nassisi

Prof. Vincenzo Nassisi

orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2004 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
FBF. Belloni
F. Belloni
DDDomenico Doria
Domenico Doria
ALAntonella LORUSSO
Antonella LORUSSO
VNVincenzo Nassisi
Vincenzo Nassisi
The experimental results of particle acceleration by plasma generated using a XeCl laser are described. The laser ion source developed is able to accelerate specific particles and to overcome the plasma effects which occur specially during the application of the accelerating voltage. In order to successfully execute this experiment, plasma expansion was highly necessary before the accelerating voltage application. For this goal an almost hermetic expanding chamber with a hole at its end, used as extraction electrode, was made. In this way arcs were eliminated and specific particles propagate in the drift tube. Time-of-flight and current intensity measurements of the ion beam have been done. The output signal, measured at 147 cm from the target, resulted modulated on ion mass-to-charge ratio and its maximum current was 220 μA at 18 kV accelerating voltage. Under the same accelerating value the bunch charge was estimated to be 4.2 nC.

1 July 1994 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
MCM. S. Causo
M. S. Causo
MMMaurizio Martino
Maurizio Martino
VNVincenzo Nassisi
Vincenzo Nassisi

1 February 2017 in Review of Scientific Instruments
Verified
Journal Article
Closed access
VNVincenzo Nassisi
Vincenzo Nassisi
DSD. Delle Side
D. Delle Side
Nowadays, the employment and development of fast current pulses require sophisticated systems to perform measurements. Rogowski coils are used to diagnose cylindrical shaped beams; therefore, they are designed and built with a toroidal structure. Recently, to perform experiments of radiofrequency biophysical stresses, flat transmission lines have been developed. Therefore, in this work we developed a linear Rogowski coil to detect current pulses inside flat conductors. The system is first approached by means of transmission line theory. We found that, if the pulse width to be diagnosed is comparable with the propagation time of the signal in the detector, it is necessary to impose a uniform current as input pulse, or to use short coils. We further analysed the effect of the resistance of the coil and the influence of its magnetic properties. As a result, the device we developed is able to record pulses lasting for some hundreds of nanoseconds, depending on the inductance, load impedance, and resistance of the coil. Furthermore, its response is characterized by a sub-nanosecond rise time (∼100 ps). The attenuation coefficient depends mainly on the turn number of the coil, while the fidelity of the response depends both on the magnetic core characteristics and on the current distribution along the plane conductors.

1 September 1993 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
ALA. Luches
A. Luches
VNVincenzo Nassisi
Vincenzo Nassisi
APA. Pecoraro
A. Pecoraro

1 January 2021 in Physics Letters A
Verified
Journal Article
Closed access
Josef KrásaJosef Krása
Josef Krása
VNVincenzo Nassisi
Vincenzo Nassisi
DKD. Klír
D. Klír

1 June 1996 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
ABA. Beloglazov
A. Beloglazov
MMMaurizio Martino
Maurizio Martino
VNVincenzo Nassisi
Vincenzo Nassisi