Vlad Mircea Lup

Mr. Vlad Mircea Lup

University of Oradea, Oradea, Bihor, Romania
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2024 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Vlad Mircea LupVlad Mircea Lup
Vlad Mircea Lup
GMGiulia Malvicini
Giulia Malvicini
CGCarlo Gaeta
Carlo Gaeta
SGSimone Grandini
Simone Grandini
GCGabriela Ciavoi
Gabriela Ciavoi
The introduction of nickel–titanium rotary instruments revolutionized shaping procedures as they were able to produce a well-tapered preparation while reducing operator fatigue. The major drawback of rotary instruments was the high risk of fracture due to bending and torsional stress. Thus, the creation of a glide path has been advocated and recommended by most rotary instrument manufacturers. The aim of the present review is to summarize existing knowledge on glide path preparation and identify areas where further research is needed. The primary goal is to provide a comprehensive overview of the techniques and instruments used in glide path preparation, highlighting their advantages and limitations. The secondary goal is to explore the effect of glide path creation on the overall success of endodontic treatment, particularly in terms of reducing procedural errors and improving treatment outcomes. An online search on PubMed, ScienceDirect, UCLA, and Scopus databases was conducted, and 116 articles were identified. Eligible articles were divided into nine categories based on what they researched and compared. The categories included centering ability and/or root canal transportation, cyclic fatigue resistance, glide path and shaping time, tortional stress resistance, apical extrusion of debris and/or bacteria, defects in dentine walls, file separation, postoperative pain assessment, and scouting ability and performance. Establishing a glide path reduces root canal transportation, especially with rotary methods. Reciprocating and heat-treated files offer higher fatigue resistance and shorter preparation time. Instruments with shorter pitch lengths have greater torsional strength. Preparation and coronal preflaring reduce apical debris and bacteria. Glide paths do not affect dentine microcracks, file separation, or defects but reduce immediate postoperative pain and improve cutting ability. Randomized trials are needed to assess their impact on treatment outcomes.

13 June 2024 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Vlad Mircea LupVlad Mircea Lup
Vlad Mircea Lup
OMOlivia Andreea Marcu
Olivia Andreea Marcu
CGCarlo Gaeta
Carlo Gaeta
GCGabriela Ciavoi
Gabriela Ciavoi
Objectives: The article’s aim is to test if rotary or reciprocating glide path influences the overall performance of WaveOne Gold in S-shaped canals. Methods: Sixty endo training blocks with an S-shape curvature were divided into three groups based on the glide path method used: no glide path; glide path preparation with ProGlider; glide path preparation with WaveOne Gold Glider. All blocks were then shaped with WaveOne Gold Primary. The time for shaping, the incidence in reaching working length and the number of pecking motions were recorded. ANOVA with Turkey’s test was used, and the p-value was set to 0.05. Results: WaveOne Gold Primary reached working length faster in the control group when comparing total working times. No significant differences in the ability of the WaveOne Gold Primary to reach working length in all groups (p > 0.05). The mean number of pecking motions was higher in the control group compared to other groups. Conclusions: No significant differences in the time needed to achieve a glide path between Proglider and WaveOne Gold Glider. WaveOne Gold Primary can shape a double curved canal faster if a glide path is present but takes less time to reach length if it is the only file used. No difference in the ability to reach working length.

13 February 2026 in European Endodontic Journal
Verified
Journal Article
Closed access
Vlad Mircea LupVlad Mircea Lup
Vlad Mircea Lup
ATAshkan Tavakkoli
Ashkan Tavakkoli
MMMichele Marciano
Michele Marciano
GCGabriela Ciavoi
Gabriela Ciavoi
SGSimone Grandini
Simone Grandini
CGCarlo Gaeta
Carlo Gaeta
Objectives: The aim of this study is to find out if undergraduate students could successfully shape an artificial S-shape root canal with the R25 Reciproc Blue instrument and if an existing glide path had an impact on their ability to reach full working length. Methods: A total of 60 students from two universities were given the task of shaping two training blocks (with and without a preestablished glide path) with the Reciproc Blue R25. The time needed for shaping, the number of pecking motions and the ability to reach working length were recorded and analyzed with the Wilcoxon signed-rank test for group comparison. In addition, paired within-student differences were summarized as medians [Q1–Q3], and Hodges–Lehmann (HL) estimates with 95% confidence intervals were computed to provide interpretable measures of central tendency and uncertainty. Results: Although all students needed more time and more pecking motions to reach working length in the no glide path group, no instrument separation occurred in any sample. Conclusions: With the aid of improved kinematics, metallurgic advancements, current endodontic motor technologies and the right protocol, even undergraduate students with limited experience in shaping root canals can reach working length on a double curved canal with no incidents even without a preestablished glide path

18 March 2026 in Эндодонтия Today
Verified
Journal Article
Open access
PDF file
NMN. Maiti
N. Maiti
Vlad Mircea LupVlad Mircea Lup
Vlad Mircea Lup
RCRiddhi Chawla
Riddhi Chawla
PAP. Agrawal
P. Agrawal
НМН. Майти
Н. Майти
РЧР. Чавла
Р. Чавла
INTRODUCTION. The intracanal fracture of nickel-titanium (NiTi) rotary instruments remains a significant procedural concern in endodontics. Advances in metallurgy, manufacturing processes, and geometric design have led to the development of new file systems with enhanced mechanical properties. The Hyflex EDM OGSF (HEDM), Protaper Ultimate (PTU), and RACE EVO (RE) systems represent distinct technological approaches to improving instrument safety. However, a direct comparative evaluation of their fracture resistance is limited. MATERIALS AND METHODS. A total of 120 new NiTi files, 40 from each system (HEDM, PTU, RE), with a tip size of 25 and a .07 taper, were selected. For the cyclic fatigue test (n = 20 per group), instruments were rotated in a custom-fabricated stainless steel artificial canal with a 60° angle of curvature and a 5 mm radius until fracture. The number of cycles to fracture (NCF) was calculated. For the torsional resistance test (n = 20 per group), the apical 3 mm of each file was clamped, and the instrument was rotated clockwise at 2 RPM until fracture, following ISO 3630-1 standards. Maximum torque (Ncm) and angular deflection (degrees) at failure were recorded. Data were statistically analyzed using one-way ANOVA and Tukey’s HSD post-hoc test (α = 0.05). RESULTS. HEDM exhibited a significantly higher mean NCF (852.5 ± 75.3) compared to both RE (621.8 ± 60.2) and PTU (455.1 ± 55.4) ( p < 0.001). RE also showed significantly higher cyclic fatigue resistance than PTU ( p < 0.001). In the torsional test, PTU demonstrated the highest maximum torque to fracture (0.46 ± 0.05 Ncm), which was significantly greater than RE (0.41 ± 0.04 Ncm) and HEDM (0.34 ± 0.06 Ncm) ( p < 0.001). The difference in torque resistance between RE and HEDM was also statistically significant ( p < 0.01). CONCLUSIONS. Within the limitations of this laboratory study, the Hyflex EDM OGSF file system demonstrated the highest resistance to cyclic fatigue. The Protaper Ultimate file system exhibited the greatest resistance to torsional fracture. The choice of instrument should be guided by the specific anatomical challenges of the root canal system.