Wajeeha Mahmood

Ms. Wajeeha Mahmood

NED University of Engineering and Technology, Karachi 75270, Pakistan
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
TATehmina Ayub
Tehmina Ayub
Wajeeha MahmoodWajeeha Mahmood
Wajeeha Mahmood
AKAsad-ur-Rehman Khan
Asad-ur-Rehman Khan
This study assesses the behaviour of self-compacting geopolymer concrete (SCGC) with and without recycled concrete aggregates (RCA) by studying the rheological, mechanical and durability properties and comparison with self-compacting concrete (SCC). The idea of using RCA in geopolymer is to attain sustainable development goals, i.e., with less carbon footprint and the use of waste materials such as fly ash and RCA. Two types of concretes were prepared, namely “self-compacting concrete (SCC)” and “self-compacting geopolymer concrete (SCGC)”. Using each concrete type, two design mixes were prepared. The first mix contained 100% natural coarse aggregates (NCA), whereas, in the second mix, 30% NCA were replaced with RCA. The result of rheological properties indicated that the viscosity, passing ability, and segregation results of SCC and SCGC mixes were higher when NCA was partially replaced with RCA. Results of mechanical properties indicated that the increase in the compressive strength of the control mix of SCC (denoted as SCC-0) and SCGC mix (denoted as SCGC-0) at 28 days was 38.3% and 33.1% higher than those containing 30% RCA (denoted as SCC-30 and SCGC-30), respectively. The percentage increase in the compressive strength of SCC-0 and SCC-30 mixes was 20.24% and 13.45% higher compared to SCGC-0 and SCGC-30 mixes. The increase in the split tensile strength of SCC-0 and SCC-30 mixes was 9% and 21.74% higher than SCGC-0 and SCGC-30 mixes. The split tensile strength of control mixes SCC-0 and SCGC-0 is 47.73% and 55% higher than SCC-30 and SCGC-30 at 28 days, respectively. Durability performance of SCC and SCGC mixes was investigated by performing hydraulic permeability, accelerated carbonation, half-cell potential and pull-out tests at 28, 90, 180, 365, and 720 days, and were found inferior for SCGC mixes. The water penetration depth of SCGC-0 and SCGC-30 mixes was 5.71% to 16.1% and 10% to 18.6% higher than SCC-0 and SCC-30 mixes at 28 to 720 days. The carbonation depth in SCGC-0 and SCGC-30 mixes was 8.11% to 20.83% and 7.89% to 13.73% higher than SCC-0 and SCC-30 mixes at 28 to 720 days. The half-cell potential difference results for SCGC-0 and SCGC-30 mixes were 27.5% to 50% and 8.3% to 16.41% higher than SCC-0 and SCC-30 mixes at 28 to 720 days. The pull-out strength of SCC-0 and SCC-30 mixes was 11.36% to 29.5% and 8.3% to 38.97% higher than SCGC-0 and SCGC-30 mixes at 28 to 720 days, respectively. Overall, the mechanical and durability properties of SCC mixes were better than SCGC at the same exposure period.

31 December 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
Wajeeha MahmoodWajeeha Mahmood
Wajeeha Mahmood
AKAsad-ur-Rehman Khan
Asad-ur-Rehman Khan
TATehmina Ayub
Tehmina Ayub
This research aims to examine the effect of carbonation on the strength properties and carbonation depth of ordinary Portland cement (OPC) concrete using two different water to cement ratios (w/c) and two different replacement percentages of natural coarse aggregate (NCA) with recycled coarse aggregate (RCA). Two concrete mixes were prepared using w/c of 0.4 and 0.43. The two concrete mixes were subdivided into two subgroups based on the use of NCA and 30% RCA. The first concrete mix having w/c of 0.4 was contained NCA and from this concrete, 42 cylinders of 100 mm dia. and 200 mm height were cast. Six out of 42 cylinders served as control specimens and were not exposed to CO2. A total of 18 out of the remaining 36 cylinders was exposed to the simulated environment and the rest were exposed to the natural environment. The second concrete mix having a w/c of 0.4 contained 30% RCA/70% NCA, and using this concrete, 42 cylinders of similar size were cast. A similar scheme was adopted for w/c of 0.43 and, in total, 84 cylinders using four mix designs were cast. After casting and 28 days of curing, six out of 42 cylinders cast from each concrete mix design were tested for compression and splitting tensile strength, following ASTM C39 and ASTM C496 without any exposure to carbon dioxide (CO2). A total of 18 out of the remaining 36 cylinders was exposed to the simulated environment in a carbonation chamber for an equivalent time duration of 90, 180 and 365 days following CEN test guidelines and the other 18 cylinders were kept in the natural environment for a period of 90, 180 and 365 days. After the completion of simulated and natural exposure periods, these cylinders were distributed equally to test for compressive strength and splitting tensile strength to observe the effect of carbon dioxide (CO2) at each time duration (i.e., 90, 180 and 365 days), and replacement percentage of RCA (i.e., 0 and 30%), which showed that carbonation depth increases incrementally with the w/c ratio and CO2 exposure duration. In both the simulated and the natural environment, the use of RCA in concrete cast using a w/c of 0.4 increased carbonation depth up to 38% and 46%, whereas, in the case of the concrete cast using a w/c ratio of 0.43, the use of RCA increased the carbonation depth up to 16% and 25%. In general, the use of RCA in the concrete exposed to the natural environment significantly affected the compressive strength of concrete, due to multiple interfaces and the porous structure of RCA, and the variation in the temperature, humidity and content of carbon dioxide (CO2) present in the actual environment. The maximum compressive strength variation prepared from the mixes M0-0.4, M30-0.43, M0-0.43 and M30-0.43 differed by 5.88%, 7.69%, 16.67% and 20% for an exposure period up to 365 days. Similarly, the results of splitting tensile strength tests on cylinders prepared from the same mixes exposed to the natural environment differ by 7.4%, 27.6%, 25.41% and 18.2% up to 365 days of exposure, respectively, as compared to the simulated environment.

21 January 2021 in Iranian Journal of Science and Technology, Transactions of Civil Engineering
Verified
Journal Article
Closed access
PDF file
TATehmina Ayub
Tehmina Ayub
Sadaqat KhanSadaqat Khan
Sadaqat Khan
Wajeeha MahmoodWajeeha Mahmood
Wajeeha Mahmood