William Ha

Dr. William Ha

University of Queensland, Australia
+2
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2017 in Materials
Verified
Journal Article
Open access
PDF file
William HaWilliam Ha
William Ha
TNTimothy Nicholson
Timothy Nicholson
BKBill Kahler
Bill Kahler
Laurence James WalshLaurence James Walsh
Laurence James Walsh
Mineral trioxide aggregate (MTA) restoratives and MTA sealers are commonly used in endodontics. Commonly referenced standards for testing of MTA are ISO 6876, 9917-1 and 10993. A PubMed search was performed relating to the relevant tests within each ISO and “mineral trioxide aggregate”. MTA restoratives are typically tested with a mixture of tests from multiple standards. As the setting of MTA is dependent upon hydration, the results of various MTA restoratives and sealers are dependent upon the curing methodology. This includes physical properties after mixing, physical properties after setting and biocompatibility. The tests of flow, film thickness, working time and setting time can be superseded by rheology as it details how MTA hydrates. Physical property tests should replicate physiological conditions, i.e. 37 °C and submerged in physiological solution. Biocompatibility tests should involve immediate placement of samples immediately after mixing rather than being cured prior to placement as this does not replicate clinical usage. Biocompatibility tests should seek to replicate physiological conditions with MTA tested immediately after mixing.

1 July 2015 in Journal of Endodontics
Verified
Journal Article
Closed access
William HaWilliam Ha
William Ha
DBDale P. Bentz
Dale P. Bentz
BKBill Kahler
Bill Kahler
Laurence James WalshLaurence James Walsh
Laurence James Walsh

26 January 2016 in Acta Biomaterialia Odontologica Scandinavica
Verified
Journal Article
Open access
PDF file
William HaWilliam Ha
William Ha
TNTimothy Nicholson
Timothy Nicholson
BKBill Kahler
Bill Kahler
LWLaurence James Walsh
Laurence James Walsh
Objective The current standard used to measure setting time for Mineral Trioxide Aggregate (MTA) involves indentation testing with arbitrary weights. This study compared indentation testing against rheological measurements and assessed the influences of particle size and the inclusion of bismuth oxide on the setting time of experimental MTA and Portland cement (PC). Material and methods Two PCs (P1 and P2) of different particle sizes were produced using the same clinker. From these two PCs, two experimental MTAs (M1 and M2) were created with the addition of bismuth oxide. Particle size distributions were assessed using laser diffraction analysis. Indentation setting time tests were performed in accordance to the Gillmore needle test. Elastic modulus was assessed using a strain-controlled rheometer at 1 rad s−1 and an applied strain of 0.01%. Results P1, P2, M1 and M2 cements had median particle sizes of 6.1, 12.5, 6.5 and 13.0 μm, respectively. Using indentation testing, final setting times were ranked P1 < M1 < P2 < M2. The ranking of the final setting time corresponded with the rheological assessment of time required to reach 95% of the elastic modulus plateau. Conclusions The time to reach 95% elastic modulus plateau of 9.3 min corresponds to a time close to the point where the material can be overlaid with another restorative material to give a final restoration. The 95% plateau value for elastic modulus may be a more useful parameter for determining how the setting reaction of PC and MTA cements progress over time.

15 September 2016 in Australian Endodontic Journal
Verified
Journal Article
Closed access
PDF file
William HaWilliam Ha
William Ha
PDPeter Duckmanton
Peter Duckmanton
BKBill Kahler
Bill Kahler
Laurence James WalshLaurence James Walsh
Laurence James Walsh

26 January 2016 in Acta Biomaterialia Odontologica Scandinavica
Verified
Journal Article
Open access
PDF file
William HaWilliam Ha
William Ha
FSFardad Shakibaie
Fardad Shakibaie
BKBill Kahler
Bill Kahler
LWLaurence James Walsh
Laurence James Walsh
Objective Mineral trioxide aggregate (MTA) cements contain two types of particles, namely Portland cement (PC) (nominally 80% w/w) and bismuth oxide (BO) (20%). This study aims to determine the particle size distribution (PSD) of PC and BO found in MTA. Materials and methods The PSDs of ProRoot MTA (MTA-P) and MTA Angelus (MTA-A) powder were determined using laser diffraction, and compared to samples of PC (at three different particle sizes) and BO. The non-linear least squares method was used to deconvolute the PSDs into the constituents. MTA-P and MTA-A powders were also assessed with scanning electron microscopy. Results BO showed a near Gaussian distribution for particle size, with a mode distribution peak at 10.48 μm. PC samples milled to differing degrees of fineness had mode distribution peaks from 19.31 down to 4.88 μm. MTA-P had a complex PSD composed of both fine and large PC particles, with BO at an intermediate size, whereas MTA-A had only small BO particles and large PC particles. Conclusions The PSD of MTA cement products is bimodal or more complex, which has implications for understanding how particle size influences the overall properties of the material. Smaller particles may be reactive PC or unreactive radiopaque agent. Manufacturers should disclose particle size information for PC and radiopaque agents to prevent simplistic conclusions being drawn from statements of average particle size for MTA materials.