Wojciech Gumiński

Dr. Wojciech Gumiński

Gdańsk University of Technology, Gdansk, Poland
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
AFAndrzej F. Frydrychowski
Andrzej F. Frydrychowski
PWPaweł Winklewski
Paweł Winklewski
Wojciech GumińskiWojciech Gumiński
Wojciech Gumiński
The aim of this study was to assess the effect of acute bilateral jugular vein compression on: (1) pial artery pulsation (cc-TQ); (2) cerebral blood flow velocity (CBFV); (3) peripheral blood pressure; and (4) possible relations between mentioned parameters. Experiments were performed on a group of 32 healthy 19–30 years old male subjects. cc-TQ and the subarachnoid width (sas-TQ) were measured using near-infrared transillumination/backscattering sounding (NIR-T/BSS), CBFV in the left anterior cerebral artery using transcranial Doppler, blood pressure was measured using Finapres, while end-tidal CO2 was measured using medical gas analyser. Bilateral jugular vein compression was achieved with the use of a sphygmomanometer held on the neck of the participant and pumped at the pressure of 40 mmHg, and was performed in the bend-over (BOPT) and swayed to the back (initial) position. In the first group (n = 10) during BOPT, sas-TQ and pulse pressure (PP) decreased (−17.6% and −17.9%, respectively) and CBFV increased (+35.0%), while cc-TQ did not change (+1.91%). In the second group, in the initial position (n = 22) cc-TQ and CBFV increased (106.6% and 20.1%, respectively), while sas-TQ and PP decreases were not statistically significant (−15.5% and −9.0%, respectively). End-tidal CO2 remained stable during BOPT and venous compression in both groups. Significant interdependence between changes in cc-TQ and PP after bilateral jugular vein compression in the initial position was found (r = −0.74). Acute bilateral jugular venous insufficiency leads to hyperkinetic cerebral circulation characterised by augmented pial artery pulsation and CBFV and direct transmission of PP into the brain microcirculation. The Windkessel effect with impaired jugular outflow and more likely increased intracranial pressure is described. This study clarifies the potential mechanism linking jugular outflow insufficiency with arterial small vessel cerebral disease.

17 April 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MNMagdalena K. Nuckowska
Magdalena K. Nuckowska
MGMarcin Gruszecki
Marcin Gruszecki
JKJacek Kot
Jacek Kot
JWJacek Wolf
Jacek Wolf
Wojciech GumińskiWojciech Gumiński
Wojciech Gumiński
PWPaweł Winklewski
Paweł Winklewski
The aim of the study was to assess cardiac and respiratory blood pressure (BP) and subarachnoid space (SAS) width oscillations during the resting state for slow and fast breathing and breathing against inspiratory resistance. Experiments were performed on a group of 20 healthy volunteers (8 males and 12 females; age 25.3 ± 7.9 years; BMI = 22.1 ± 3.2 kg/m2). BP and heart rate (HR) were measured using continuous finger-pulse photoplethysmography. SAS signals were recorded using an SAS monitor. Oxyhaemoglobin saturation (SaO2) and end-tidal CO2(EtCO2) were measured using a medical monitoring system. Procedure 1 consisted of breathing spontaneously and at controlled rates of 6 breaths/minute and 6 breaths/minute with inspiratory resistance for 10 minutes. Procedure 2 consisted of breathing spontaneously and at controlled rates of 6, 12 and 18 breaths/minute for 5 minutes. Wavelet analysis with the Morlet mother wavelet was applied for delineation of BP and SAS signals cardiac and respiratory components. Slow breathing diminishes amplitude of cardiac BP and SAS oscillations. The overall increase in BP and SAS oscillations during slow breathing is driven by the respiratory component. Drop in cardiac component of BP amplitude evoked by slow-breathing may be perceived as a cardiovascular protective mechanism to avoid target organ damage. Further studies are warranted to assess long-term effects of slow breathing.

18 August 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
PWPaweł Winklewski
Paweł Winklewski
OBOtto F Barak
Otto F Barak
DMDennis Madden
Dennis Madden
AGAgnieszka Gruszecka
Agnieszka Gruszecka
MGMarcin Gruszecki
Marcin Gruszecki
ZDZeljko Dujic
Zeljko Dujic
The aim of the study was to assess changes in subarachnoid space width (sas-TQ), the marker of intracranial pressure (ICP), pial artery pulsation (cc-TQ) and cardiac contribution to blood pressure (BP), cerebral blood flow velocity (CBFV) and cc-TQ oscillations throughout the maximal breath hold in elite apnoea divers. Non-invasive assessment of sas-TQ and cc-TQ became possible due to recently developed method based on infrared radiation, called near-infrared transillumination/backscattering sounding (NIR-T/BSS). The experimental group consisted of seven breath-hold divers (six men). During testing, each participant performed a single maximal end-inspiratory breath hold. Apnoea consisted of the easy-going and struggle phases (characterised by involuntary breathing movements (IBMs)). Heart rate (HR) was determined using a standard ECG. BP was assessed using the photoplethysmography method. SaO2 was monitored continuously with pulse oximetry. A pneumatic chest belt was used to register thoracic and abdominal movements. Cerebral blood flow velocity (CBFV) was estimated by a 2-MHz transcranial Doppler ultrasonic probe. sas-TQ and cc-TQ were measured using NIR-T/BSS. Wavelet transform analysis was performed to assess cardiac contribution to BP, CBFV and cc-TQ oscillations. Mean BP and CBFV increased compared to baseline at the end of the easy phase and were further augmented by IBMs. cc-TQ increased compared to baseline at the end of the easy phase and remained stable during the IBMs. HR did not change significantly throughout the apnoea, although a trend toward a decrease during the easy phase and recovery during the IBMs was visible. Amplitudes of BP, CBFV and cc-TQ were augmented. sas-TQ and SaO2 decreased at the easy phase of apnoea and further decreased during the IBMs. Apnoea increases intracranial pressure and pial artery pulsation. Pial artery pulsation seems to be stabilised by the IBMs. Cardiac contribution to BP, CBFV and cc-TQ oscillations does not change throughout the apnoea.

1 May 2015 in Microvascular Research
Verified
Journal Article
Closed access
PWPaweł Winklewski
Paweł Winklewski
MGMarcin Gruszecki
Marcin Gruszecki
JWJ. Wolf
J. Wolf
ESE. Swierblewska
E. Swierblewska
KKK. Kunicka
K. Kunicka
KNKrzysztof Narkiewicz
Krzysztof Narkiewicz

18 August 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
PWPaweł Winklewski
Paweł Winklewski
YTYurii Tkachenko
Yurii Tkachenko
KMKamila Mazur
Kamila Mazur
JKJacek Kot
Jacek Kot
MGMarcin Gruszecki
Marcin Gruszecki
AFAndrzej F. Frydrychowski
Andrzej F. Frydrychowski
Using a novel method called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) and subarachnoid width (sas-TQ) in humans, we assessed the influence of sympathetic activation on the cardiac and respiratory contribution to blood pressure (BP) cc-TQ oscillations in healthy subjects. The pial artery and subarachnoid width response to handgrip (HGT) and cold test (CT) were studied in 20 healthy subjects. The cc-TQ and sas-TQ were measured using NIR-T/BSS; cerebral blood flow velocity (CBFV) was measured using Doppler ultrasound of the left internal carotid artery; heart rate (HR) and beat-to-beat mean BP were recorded using a continuous finger-pulse photoplethysmography; respiratory rate (RR), minute ventilation (MV), end-tidal CO2 (EtCO2) and end-tidal O2 (EtO2) were measured using a metabolic and spirometry module of the medical monitoring system. Wavelet transform analysis was used to assess the relationship between BP and cc-TQ oscillations. HGT evoked an increase in BP (+15.9%; P<0.001), HR (14.7; P<0.001), SaO2 (+0.5; P<0.001) EtO2 (+2.1; P<0.05) RR (+9.2%; P = 0.05) and MV (+15.5%; P<0.001), while sas-TQ was diminished (-8.12%; P<0.001), and a clear trend toward cc-TQ decline was observed (-11.0%; NS). CBFV (+2.9%; NS) and EtCO2 (-0.7; NS) did not change during HGT. CT evoked an increase in BP (+7.4%; P<0.001), sas-TQ (+3.5%; P<0.05) and SaO2(+0.3%; P<0.05). HR (+2.3%; NS), CBFV (+2.0%; NS), EtO2 (-0.7%; NS) and EtCO2 (+0.9%; NS) remained unchanged. A trend toward decreased cc-TQ was observed (-5.1%; NS). The sas-TQ response was biphasic with elevation during the first 40 seconds (+8.8% vs. baseline; P<0.001) and subsequent decline (+4.1% vs. baseline; P<0.05). No change with respect to wavelet coherence and wavelet phase coherence was found between the BP and cc-TQ oscillations. Short sympathetic activation does not affect the cardiac and respiratory contribution to the relationship between BP—cc-TQ oscillations. HGT and CT display divergent effects on the width of the subarachnoid space, an indirect marker of changes in intracranial pressure.

1 September 2015 in Journal Of Hypertension
Verified
Journal Article
Closed access
MWMagdalena Wszędybył-Winklewska
Magdalena Wszędybył-Winklewska
JWJacek Wolf
Jacek Wolf
ESEwa Swierblewska
Ewa Swierblewska
KKKatarzyna Kunicka
Katarzyna Kunicka
MGMarcin Gruszecki
Marcin Gruszecki
KNKrzysztof Narkiewicz
Krzysztof Narkiewicz
Little is known about intracranial pressure (ICP)-cerebral haemodynamic interplay during repetitive apnoea. A recently developed method based on near-infrared transillumination/backscattering sounding (NIR-T/BSS) noninvasively measures changes in pial artery pulsation (cc-TQ) as well as subarachnoid width (sas-TQ) in humans. We tested the complex response of the pial artery and subarachnoid width to apnoea using this method. The pial artery and subarachnoid width response to consecutive apnoeas lasting 30, 60 s and maximal breath-hold (91.1 ± 23.1 s) were studied in 20 healthy volunteers. The cc-TQ and sas-TQ were measured using NIR-T/BSS; cerebral blood flow velocity (CBFV), pulsatility index and resistive index were measured using Doppler ultrasound of the left internal carotid artery; heart rate (HR) and beat-to-beat SBP and DBP blood pressure were recorded using a Finometer; end-tidal CO2 (EtCO2) was measured using a medical gas analyser. Apnoea evoked a multiphasic response in blood pressure, pial artery compliance and ICP. First, SBP declined, which was accompanied by an increase in cc-TQ and sas-TQ. Directly after these changes, SBP exceeded baseline values, which was followed by a decline in cc-TQ and the return of sas-TQ to baseline. During these initial changes, CBFV remained stable. Towards the end of the apnoea, BP, cc-TQ and CBFV increased, whereas pulsatility index, resistive index and sas-TQ declined. Changes in sas-TQ were linked to changes in EtCO2, HR and SBP. Apnoea is associated with ICP swings, closely reflecting changes in EtCO2, HR and peripheral BP. The baroreflex influences the pial artery response.