Yangyang Zou

Dr. Yangyang Zou

Jilin Univeisity
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
YZYangyang Zou
Yangyang Zou
LZLiu Zhang
Liu Zhang
JZJian Zhang
Jian Zhang
BLBonan Li
Bonan Li
XLXueying Lv
Xueying Lv
The bidirectional reflection distribution function (BRDF) is among the most effective means to study the phenomenon of light–object interaction. It can precisely describe the characteristics of spatial reflection of the target surface, and has been applied to aerial remote sensing, imaging technology, materials analysis, and computer rendering technology. This study provides a comprehensive review of the development of devices to measure the BRDF. We gathered research in the area by using the Web of Science Core Collection, and show that work on the BDRF has been ongoing in the last 30 years. We also describe some typical measurement devices for the BRDF proposed in the literature. Finally, we summarise outstanding problems related to BRDF measurement and propose directions of future research in the area.

14 March 2022 in Applied Optics
Verified
Journal Article
Closed access
PDF file
YZYangyang Zou
Yangyang Zou
LZLiu Zhang
Liu Zhang
JZJian Zhang
Jian Zhang
JCJicheng Cui
Jicheng Cui
A synchronous multi-angle scattered light field measurement system is constructed in this study to overcome issues with current systems in the field of multi-angle remote sensing. A mathematical model of the scattered light field measurement was established. An off-axis catadioptric optical system was designed to satisfy hemispheric spatial scattered light field measurements in a zenith angle range of 68°. The off-axis calibration model was established, and the spatial relationship was calibrated. The measurement accuracy was calibrated via an integrating sphere light source, and the maximum measurement relative error was − 3.71 % . The scattered light field of the reference diffuse reflective target plate Labsphere Permaflect-50 and 304 stainless steel was simulated under an incident light irradiation range within the zenith angle of − 23.5 ∘ to + 23.5 ∘ , and synchronous measurement of the multi-angle scattered light field of the sample was realized. The measurement system could provide technical support for building the complex model of multi-angle reflection/radiation from the earth’s surface, multi-angle sensor radiation calibration, and improvement of the physical parameter inversion accuracy of observation targets.

28 January 2025 in Optics Express
Verified
Journal Article
Closed access
JSJingrui Sun
Jingrui Sun
JZJian Zhang
Jian Zhang
XMXiaoxu Mo
Xiaoxu Mo
LWLu Wang
Lu Wang
BZBin Zhao
Bin Zhao
GZGuoyu Zhang
Guoyu Zhang
Accurate measurements of direct solar radiation spectra are crucial for atmospheric science, climatology, agriculture, and solar energy. Existing systems depend on costly dual-axis tracking devices, leading to high maintenance and error rates. This study presents a free-form surface-based polar-axis rotating solar direct radiation spectrometer, enabling year-round measurements across all latitudes without mobile tracking. The system operates in the 380–780 nm range with a spectral resolution better than 2 nm. Simulation results demonstrate spectral curve area errors between 0.68% and 1.22%, and outdoor experiments in Changchun, China, confirm the accuracy of measurements against the AM1.5 G standard.