Yifeng Bu

Dr. Yifeng Bu

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2026 in Comprehensive Physiology
Verified
Journal Article
Open access
Yifeng BuYifeng Bu
Yifeng Bu
ALAlex Liang
Alex Liang
BHBenjamin U. Hoffman
Benjamin U. Hoffman
DSDawn M. Schiehser
Dawn M. Schiehser
OCOliver Case
Oliver Case
ILImanuel Lerman
Imanuel Lerman
Vagus nerve stimulation (VNS) is an established neuromodulatory therapy approved for epilepsy, depression, obesity, stroke rehabilitation, rheumatoid arthritis, migraine, and cluster headaches. Its therapeutic potential has expanded dramatically, with growing evidence supporting its efficacy across a wide spectrum of neurological, psychiatric, cardiovascular, immunological, metabolic, and gastrointestinal disorders. Despite this progress, the field has lacked a comprehensive synthesis that unifies mechanistic insights with translational applications across organ systems. This review addresses that gap by systematically integrating current knowledge in the multifactorial mechanisms through which VNS modulates central and peripheral functions, including neuromodulator release, synaptic plasticity, autonomic regulation, neuroimmune control, and endocrine integration. In addition, this review identifies key limitations of VNS, including biological heterogeneity, technical constraints, and methodological variability, and proposes future innovations such as selective fiber targeting, closed‐loop systems, and artificial intelligence‐guided personalization. By providing a rigorous, system‐level overview of VNS mechanisms and their translational relevance, this article serves as a foundational resource for advancing the science and clinical deployment and helping illustrate future directions for precision neuromodulation and bioelectronic medicine.

14 November 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Yifeng BuYifeng Bu
Yifeng Bu
JKJonas F. Kurniawan
Jonas F. Kurniawan
JPJacob Prince
Jacob Prince
ANAndrew K. L. Nguyen
Andrew K. L. Nguyen
BHBrandon Ho
Brandon Ho
ILImanuel Lerman
Imanuel Lerman
This study introduces a flexible, adhesive-integrated electrode array that was developed to enable non-invasive monitoring of cervical nerve activity. The device uses silver-silver chloride as the electrode material of choice and combines it with an electrode array consisting of a customized biopotential data acquisition unit and integrated graphical user interface (GUI) for visualization of real-time monitoring. Preliminary testing demonstrated this electrode design can achieve a high signal to noise ratio during cervical neural recordings. To demonstrate the capability of the surface electrodes to detect changes in cervical neuronal activity, the cold-pressor test (CPT) and a timed respiratory challenge were employed as stressors to the autonomic nervous system. This sensor system recording, a new technique, was termed Cervical Electroneurography (CEN). By applying a custom spike sorting algorithm to the electrode measurements, neural activity was classified in two ways: (1) pre-to-post CPT, and (2) during a timed respiratory challenge. Unique to this work: (1) rostral to caudal channel position-specific (cephalad to caudal) firing patterns and (2) cross challenge biotype-specific change in average CEN firing, were observed with both CPT and the timed respiratory challenge. Future work is planned to develop an ambulatory CEN recording device that could provide immediate notification of autonomic nervous system activity changes that might indicate autonomic dysregulation in healthy subjects and clinical disease states.

1 October 2026 in Physiological Reviews
Verified
Journal Article
Closed access
RMRavinder K. Mittal
Ravinder K. Mittal
Yifeng BuYifeng Bu
Yifeng Bu
NSNick J. Spencer
Nick J. Spencer
The mechanism of esophageal peristalsis or sequential contractions of the skeletal and smooth muscle esophagus resides at multiple levels, i.e., brain stem (central pattern generator), neurons within the wall of the esophagus (myenteric plexus), and smooth muscle (myogenic). Esophageal peristalsis consists of initial inhibition followed by excitation, for which there may be parallel pathways from the central pattern generator, traveling via the vagus nerve to communicate with the inhibitory and excitatory neurons of the myenteric plexus. Primary and secondary esophageal peristalsis are associated with concurrent contraction and relaxation of the circular and longitudinal muscle layers. The longitudinal muscle contraction in the contracted segment exerts mechanical stretch on the segment ahead of it, which likely activates the mechanosensitive inhibitory motor neurons in the myenteric plexus to induce descending relaxation, a peripheral mechanism of the peristaltic reflex. In achalasia esophagus, there is inflammation and fibrosis in the muscularis propria and myenteric plexus, resulting in loss of inhibitory nerves in the myenteric plexus. It also results in replacement of muscle with fibrous tissue in the muscularis propria of the lower esophageal sphincter (LES), impaired LES relaxation, and low distensibility of the esophagogastric junction in achalasia esophagus. The esophageal hiatus contains a pad of fat that is replaced with fibrosis in patients with achalasia esophagus. Whether hiatal fibrosis leads to impaired LES relaxation/low distensibility of the esophagogastric junction and changes in esophageal peristalsis are secondary to obstruction requires further study. Esophageal hypersensitivity is currently the favored mechanism of “angina-like” esophageal pain and refractory heartburn. Spastic or long-duration contractions of the longitudinal muscle of the esophagus may also play a role in the genesis of noncardiac esophageal pain and heartburn sensation.

11 July 2022 in bioRxiv
Verified
Preprint
Open access
PDF file
Yifeng BuYifeng Bu
Yifeng Bu
JKJonas F. Kurniawa
Jonas F. Kurniawa
JPJacob Prince
Jacob Prince
ANAndrew K. L. Nguyen
Andrew K. L. Nguyen
BHBrandon Ho
Brandon Ho
ILImanuel Lerman
Imanuel Lerman
This study introduces a flexible, adhesive-integrated electrode array that was developed to enable non-invasive monitoring of cervical nerve activity. The device uses silver-silver chloride as the electrode material of choice and combines it with a novel electrode array consisting of a customized biopotential data acquisition unit and integrated graphical user interface (GUI) for visualization of real-time monitoring. Preliminary testing demonstrated this novel electrode design can achieve a high signal to noise ratio during cervical neural recordings. To demonstrate the capability of the surface electrodes to detect changes in cervical neuronal activity, the cold-pressor test (CPT) and a timed respiratory challenge were employed as stressors to the autonomic nervous system. This sensor system recording, a new novel technique, was termed Cervical Electroneurography (CEN). By applying a custom spike sorting algorithm to the novel electrode measurements, neural activity was classified in two ways: 1) pre-to-post CPT, and 2) during a timed respiratory challenge. Unique to this work: 1) rostral to caudal channel position-specific (cephalad to caudal) firing patterns and 2) cross challenge biotype-specific change in average CEN firing, were observed with both CPT and the timed respiratory challenge. Future work is planned to develop an ambulatory CEN recording device that could provide immediate notification of autonomic nervous system activity changes that might indicate autonomic dysregulation in healthy subjects and clinical disease states.

11 July 2022 in Research Square
Verified
Preprint
Open access
PDF file
Yifeng BuYifeng Bu
Yifeng Bu
JKJonas F. Kurniawa
Jonas F. Kurniawa
JPJacob Prince
Jacob Prince
ANAndrew K. L. Nguyen
Andrew K. L. Nguyen
BHBrandon Ho
Brandon Ho
ILImanuel Lerman
Imanuel Lerman
This study introduces a flexible, adhesive-integrated electrode array that was developed to enable non-invasive monitoring of cervical nerve activity. The device uses silver-silver chloride as the electrode material of choice and combines it with a novel electrode array consisting of a customized biopotential data acquisition unit and integrated graphical user interface (GUI) for visualization of real-time monitoring. Preliminary testing demonstrated this novel electrode design can achieve a high signal to noise ratio during cervical neural recordings. To demonstrate the capability of the surface electrodes to detect changes in cervical neuronal activity, the cold-pressor test (CPT) and a timed respiratory challenge were employed as stressors to the autonomic nervous system. This sensor system recording, a new novel technique, was termed Cervical Electroneurography (CEN). By applying a custom spike sorting algorithm to the novel electrode measurements, neural activity was classified in two ways: 1) pre-to-post CPT, and 2) during a timed respiratory challenge. Unique to this work: 1) rostral to caudal channel position-specific (cephalad to caudal) firing patterns and 2) cross challenge biotype-specific change in average CEN firing, were observed with both CPT and the timed respiratory challenge. Future work is planned to develop an ambulatory CEN recording device that could provide immediate notification of autonomic nervous system activity changes that might indicate autonomic dysregulation in healthy subjects and clinical disease states.