Yoshitaka Nakanishi

Prof. Yoshitaka Nakanishi

Kumamoto University, Kumamoto, Japan
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Procedia CIRP
Verified
Journal Article
Open access
LYLing Yin
Ling Yin
Yoshitaka NakanishiYoshitaka Nakanishi
Yoshitaka Nakanishi
AAAbdur-Rasheed Alao
Abdur-Rasheed Alao
XSXiao-Fei Song
Xiao-Fei Song
JAJaafar Abduo
Jaafar Abduo
YZYu Zhang
Yu Zhang
Zirconia is widely used for load-bearing functional structures in medicine and dentistry. The quality of engineered zirconia surfaces determines not only the fracture and fatigue behaviour but also the low temperature degradation (ageing sensitivity), bacterial colonization and bonding strength of zirconia devices. This paper reviews the current manufacturing techniques for fabrication of zirconia surfaces in biomedical applications, particularly, in tooth and joint replacements, and influences of the zirconia surface quality on their functional behaviours. It discusses emerging manufacturing techniques and challenges for fabrication of zirconia surfaces in biomedical applications.

2 July 2003 in Arthritis & Rheumatism
Verified
Journal Article
Open access
PDF file
TKTsutomu Kawano
Tsutomu Kawano
HMHiromasa Miura
Hiromasa Miura
TMTaro Mawatari
Taro Mawatari
TMTakaaki Moro‐Oka
Takaaki Moro‐Oka
Yoshitaka NakanishiYoshitaka Nakanishi
Yoshitaka Nakanishi
YIYukihide Iwamoto
Yukihide Iwamoto
Objective: To examine in vivo the effects of a mixture of high molecular weight hyaluronic acid (HA) plus phospholipids on joint lubrication and articular cartilage degeneration.Methods: Experimental osteoarthritis (OA) of the right knee was induced by anterior cruciate and medial collateral ligament transection in 40 rabbits. The animals were subjected to 8 consecutive weekly intraarticular administrations of high molecular weight HA (the HA200 group), conventional molecular weight HA (the HA80 group), or high molecular weight HA plus L‐δ dipalmitoyl phosphatidylcholine liposomes (the PHA group) and were killed 1 week after the final injection. The remaining transected right knees (the OA group) and randomly selected nontransected contralateral left knees (the control group) were collected simultaneously. Each group (n = 10) was divided into 2 equal subgroups, one of which was evaluated histologically while the other was subjected to a lubricating ability test using a pendulum friction tester.Results: The injected knees had a tendency to demonstrate less damage to the articular cartilage compared with the OA group, and the histologic findings in all groups except for the PHA group differed significantly from the control group. There was a significant difference in the mean ± SD friction coefficient between the control group (0.0100 ± 0.00300) and the OA (0.0206 ± 0.00649), HA200 (0.0190 ± 0.00427), and HA80 (0.0177 ± 0.00712) groups (P < 0.05 for each comparison), but not between the control group and the PHA group (0.0150 ± 0.00330) (P = 0.15).Conclusion: To our knowledge, this is the first in vivo study to examine whether intraarticular injections of phospholipids influence joint lubrication by acting as a boundary lubricant, thus protecting articular cartilage from degenerative changes.

1 February 2009 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
YTYasutaka Tashiro
Yasutaka Tashiro
HMHiromasa Miura
Hiromasa Miura
Yoshitaka NakanishiYoshitaka Nakanishi
Yoshitaka Nakanishi
KOKen Okazaki
Ken Okazaki
YIYukihide Iwamoto
Yukihide Iwamoto
Rm better on a simulated arthroscopic procedure than novices, therefore validating the quantitative assessment. Surgical trainees (n = 12), orthopaedic residents (n = 12), and experienced arthroscopic surgeons (n = 6) were tested on a Sawbones® knee simulator. Subjects performed a joint inspection and probing task and a partial meniscectomy task. The trajectory data were measured using an electromagnetic motion tracking system and the force data were measured using a force sensor. The experienced group performed both tasks with higher scores and more quickly than the less experienced groups. The path length of the probe and the scissors was substantially shorter and the probe velocity was considerably faster in the experienced group. The trainee group applied substantially stronger forces to the joint during the joint inspection and probing task. Our data suggest a performance assessment using an electromagnetic motion tracking system and a force sensor provides an objective means of evaluating surgical skills in an arthroscopic training system....

1 March 2016 in Biosurface and Biotribology
Verified
Journal Article
Open access
HCH. Chikaura
H. Chikaura
YNY. Nakashima
Y. Nakashima
YFY. Fujiwara
Y. Fujiwara
YKY. Komohara
Y. Komohara
MTM. Takeya
M. Takeya
Yoshitaka NakanishiYoshitaka Nakanishi
Yoshitaka Nakanishi
Ultra-high molecular weight polyethylene (UHMWPE) wear particles from artificial joints induce osteolysis and the subsequent loosening of implants. Studies have reported that particles in the size range of 0.1–10μm are the most biologically active in macrophage immune response. To develop prosthetic joints with greater longevity and durability, it is crucial to understand the deleterious effects of wear particles. In this study, to evaluate the effects of particle size on the activities of human monocyte-derived macrophages (HMDMs), seven differently sized particles of polymethylmethacrylate (PMMA), in the range of 0.1–20μm, were prepared. Viability and the secretion of cytokines were evaluated after phagocytosis of each size particles by HMDMs. Differences in the viability of HMDMs after phagocytosis of particles sized 0.16–9.6μm were statistically significant. Proinflammatory cytokine production of both tumor necrosis factor-α and interleukin-6 by HMDMs was strongly induced by 0.8μm PMMA particles. Consistent with the fact that macrophages are known to respond to pathogens measuring approximately 1.0μm in size, in this study, PMMA particles measuring 0.8μm in size induced an immune response. This work provides fundamental data for the designing of surface profiles of prosthetic joints, Which may expect the lower incidence of immune response

19 October 2011 in The American Journal of Sports Medicine
Verified
Journal Article
Closed access
HMHirokazu Matsubara
Hirokazu Matsubara
KOKen Okazaki
Ken Okazaki
TIToshiaki Izawa
Toshiaki Izawa
YTYasutaka Tashiro
Yasutaka Tashiro
SMShuichi Matsuda
Shuichi Matsuda
YIYukihide Iwamoto
Yukihide Iwamoto
Background: Repair of complete radial meniscal tears is a key to restoring the mechanical integrity necessary to maintain hoop tension in the meniscus. The primary stability of the meniscal repair is one of the most important factors for meniscal healing, but the biomechanical structural properties of different repair techniques for complete radial meniscal tears remain unknown. Hypothesis: Our novel cross-suture technique with suturing oblique to the collagen fibrils of the meniscus will yield better fixation than the standard double horizontal suture technique with suturing parallel to the collagen fibrils in the meniscus. Study Design: Controlled laboratory study. Methods: Biomechanical investigation was performed on 40 fresh human menisci (2 groups of 20 menisci each) from patients who underwent total knee arthroplasty. In the cross-suture technique group (group A), the sutures crossed over 5 mm from the tear and 5 mm and 10 mm from the rim. In the double horizontal suture technique group (group B), the sutures were parallel and had the same attachment points as group A. The specimens were cyclically loaded 500 times between 5 and 30 N and then loaded to failure after completion of the cyclic load testing. Results: Compared with the double horizontal suture group, the cross-suture group had a significantly higher ultimate failure load (78.96 ± 19.27 N vs 68.16 ± 12.92 N; P < .05), significantly greater stiffness (8.01 ± 1.54 N/mm vs 6.46 ± 1.12 N/mm; P < .05), and significantly lower displacement (5.74 ± 1.84 mm vs 8.56 ± 2.39 mm; P < .05) after a 500–cycle loading protocol. Conclusion: Our cross-suture technique significantly improved the structural properties of the repaired complete radial meniscal tears. Clinical Relevance: The cross-suture technique for repair of radial meniscal tears provides high stability and could be a promising solution in young and in active patients.

4 March 2009 in The American Journal of Sports Medicine
Verified
Journal Article
Closed access
YTYasutaka Tashiro
Yasutaka Tashiro
KOKen Okazaki
Ken Okazaki
HMHiromasa Miura
Hiromasa Miura
SMShuichi Matsuda
Shuichi Matsuda
TYTakefumi Yasunaga
Takefumi Yasunaga
YIYukihide Iwamoto
Yukihide Iwamoto
Background: Anterior cruciate ligament reconstruction successfully reduces anterior knee instability, but its effect on rotatory stability is not fully understood. In addition, a definitive method for the quantitative evaluation of rotatory instability remains to be established. Hypothesis: Measurement of anterolateral tibial translation by open magnetic resonance imaging could positively correlate with the clinical grading of the pivot-shift test and would clarify residual rotatory abnormalities not shown by conventional methods for measurement of anterior stability. Study Design: Controlled laboratory study. Methods: An anterior cruciate ligament—reconstructed group (n = 21) and an anterior cruciate ligament—deficient group (n = 20) were examined using a Slocum anterolateral rotatory instability test in open magnetic resonance imaging. Anterior tibial translation was measured at the medial and lateral compartments by evaluating sagittal images. Clinical knee stability was evaluated before the above measurement using the pivot-shift test, KT-2000 arthrometer, and stress radiography. A cutoff value for anterolateral tibial translation relating to pivot-shift was determined using a receiver operating characteristic curve. Results: Side-to-side differences of anterolateral tibial translation correlated with clinical grade of the pivot-shift test and stress radiography but not with KT-2000 arthrometry in both groups. The cutoff value was established as 3.0 mm. Although the mean anterolateral translation showed no difference, 9 reconstructed knees revealed greater than 3 mm of anterolateral tibial translation, whereas only 3 uninjured knees did. Conclusion: Measurement using an open magnetic resonance imaging successfully quantified the remaining rotatory instability in anterior cruciate ligament—reconstructed knees. Clinical Relevance: This method is a useful means for quantifying anterior cruciate ligament function to stabilize tibial rotation.