Young Rak Choi

Prof. Dr. Young Rak Choi

Asan Medical Center, Seoul, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2019 in BioMed Research International
Verified
Journal Article
Open access
PDF file
HKHwa Jun Kang
Hwa Jun Kang
BKBom Soo Kim
Bom Soo Kim
SKSeung Min Kim
Seung Min Kim
YKYu Mi Kim
Yu Mi Kim
HKHyong Nyun Kim
Hyong Nyun Kim
YCYoung Rak Choi
Young Rak Choi
This study aimed to determine if 3D printing can affect surgeon’s selection of plate for distal tibia fracture surgery and to find out whether orthopedic surgeons consider this technology necessary and would use it in their practice. A total of 102 orthopedic surgeons were asked to choose anatomically contoured locking plates among 5 most commonly used types for one simple and one complex distal tibia fracture based on X-ray and CT images. Next, they were provided real-size 3D printed models of the same fractures, allowed to apply each of the 5 plates to these models, and asked if they would change their choice of plate. A 10-point numeric rating scale was provided to measure the extent of the help that 3D printing provided on preoperative planning. Finally, we asked the surgeons if they would use 3D printing in their practice. Seventy-four percent of inexperienced surgeons changed their selection of plate after using 3D printed models for the complex fracture. In contrast, only 9% of experienced surgeons changed their selection of plate for the simple fracture. Surgeons rated the extent of usefulness of the 3D models in preoperative planning as a mean of 4.84 ± 2.54 points for the simple fracture and 6.63 ± 2.54 points for the complex fracture. The difference was significant (p < 0.001). Eighty-six percent of inexperienced surgeons wanted to use 3D models for complex fractures. However, only 18% of experienced surgeons wanted to use 3D printed models for simple fractures. The use of a real-size 3D-printed model often changed surgeon’s preoperative selection of locking plates, especially when inexperienced surgeons evaluated a complex fracture. However, experienced surgeons did not find 3D models very useful when assessing simple fractures. Future applications of 3D models should focus on training beginners in fracture surgery, especially when complex fractures are concerned.

29 October 2020 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
SCSeongJu Choi
SeongJu Choi
YCYoung Rak Choi
Young Rak Choi
EBEugene Baek
Eugene Baek
SJSeongmin Jo
Seongmin Jo

2 December 2020 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
YCYoung Rak Choi
Young Rak Choi
BKBom Soo Kim
Bom Soo Kim
YKYu Mi Kim
Yu Mi Kim
JPJae Yong Park
Jae Yong Park
Jaeho ChoJaeho Cho
Jaeho Cho
HKHyong Nyun Kim
Hyong Nyun Kim
Background: The purpose of this study was to determine whether tolerated weight-bearing in a hard-soled shoe was noninferior to the use of a short leg cast for the treatment of a fifth metatarsal base avulsion fracture, as assessed with use of a 100-mm visual analog scale (VAS) for pain at 6 months after the fracture. Methods: A total of 145 patients were assessed for eligibility. Of these, 96 patients were randomly assigned to either the hard-soled shoe group (46 patients) or the cast group (50 patients). The primary outcome measure was the mean difference on the 100-mm VAS between groups at 6 months after the fracture. Secondary outcome measures included the time to return to preinjury activity and patient-reported satisfaction. Analysis was performed according to both an intention-to-treat basis (i.e., patients were included in the assessment of their assigned treatment arm, even if they crossed over to the other treatment arm prior to completing the 6-month follow-up) and a per-protocol basis (i.e., patients who completed the 6-month follow-up were analyzed according to the treatment they received). Results: At 6 months after the fracture, the mean 100-mm VAS was 8.6 ± 7.0 mm in the hard-soled shoe group and 9.8 ± 7.3 mm in the cast group (p = 0.41) according to intention-to-treat analysis. The mean difference in 100-mm VAS between the 2 groups was −1.3 mm (95% confidence interval, −4.3 to 1.8 mm). The upper limit of the 95% confidence interval did not exceed the noninferiority margin of 10 mm, indicating that treatment with the hard-soled shoe was noninferior to treatment with the short leg cast. The proportion of patients who reported satisfaction with their treatment was similar between the hard-soled shoe and cast groups (89.5% compared with 87.5%, respectively; p = 0.79), but the time to return to preinjury activity was significantly shorter in the hard-soled shoe group (37.2 ± 14.4 days compared with 43.0 ± 11.1 days in the cast group; p = 0.04). There were no cases of nonunion in either group. Conclusions: Weight-bearing as tolerated in a hard-soled shoe for a fifth metatarsal base avulsion fracture was noninferior to the use of a short leg cast as assessed with use of a 100-mm VAS at 6 months after the fracture. Patient-reported satisfaction was similar between groups, but the time to return to preinjury activity was shorter in the hard-soled shoe group. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.


28 December 2022 in Foot & Ankle International
Verified
Journal Article
Closed access
TKTae-Hoon Kim
Tae-Hoon Kim
YCYoung Rak Choi
Young Rak Choi
HLHo-seong Lee
Ho-seong Lee
GBGyeong-Gu Bak
Gyeong-Gu Bak
SMSung-Ho Moon
Sung-Ho Moon
Background: Recurrence of the hallux valgus deformity has various causes, and the incomplete reduction of sesamoids may be one of the important issues. However, we have seen several patients with postoperative lateral sesamoid displacement on anteroposterior (AP) standing radiographs who did not experience hallux valgus recurrence. Therefore, we hypothesized that lateral displacement of the sesamoid on AP standing radiographs does not cause hallux valgus recurrence. Methods: The study included 269 feet (185 patients) with hallux valgus treated with distal chevron metatarsal osteotomy. Mean patient age was 64.26 (range, 15-80) years. Patients were followed up for an average of 33.85 (range, 12-228) months between April 2002 and December 2019. The patients were divided into 4 groups, according to the presence or absence of hallux valgus recurrence and sesamoid reduction. Results: During outpatient follow-up, we discovered 99 feet (42.1%) in which hallux valgus did not recur despite lateral sesamoid displacement (grade IV-VII) on AP standing radiographs. Hallux valgus angle (HVA, 2.7 to 7.9 degrees), intermetatarsal angle (IMA, 4.6 to 6.2 degrees), and sesamoid grades (2.1 to 3.5) all deteriorated over time after surgery, and each indicator was statistically significantly altered, and changes in the 3 indicators had a statistically significant positive correlation. Changes in HVA and IMA between feet with and without sesamoid reduction on AP standing radiographs increased over time, with the differences in HVA (2.9 degrees) and IMA (0.9 degrees) being significant at final follow-up ( P < .05 for each). Regardless of whether sesamoid reduction was achieved on AP standing radiographs, the final analysis showed that HVA and IMA in both groups worsened over time. Further, there were no differences between the 2 groups in the patterns of change over time. Conclusion: In our cohort, postoperative sesamoid position on AP standing radiographs was not associated with hallux valgus recurrence based on radiographic criteria. Level of Evidence: Level III, retrospective comparative study.

JKJahyung Kim
Jahyung Kim
HKHwa-Jun Kang
Hwa-Jun Kang
BKBom-Soo Kim
Bom-Soo Kim
YKYu-Mi Kim
Yu-Mi Kim
HKHyong Nyun Kim
Hyong Nyun Kim
Jaeho ChoJaeho Cho
Jaeho Cho
We aimed to investigate the clinical manifestations, radiological findings, and therapeutic outcome of treatment for patients with surgically confirmed foreign body reaction following an Achilles tendon repair using non-absorbable suture material. Eight consecutive patients who were confirmed as having an intra-tendinous suture foreign body reaction in the histopathological report were enrolled in this study. Medical records of all patients in terms of clinical and radiological features were retrieved. Also, the outcome of treatment was evaluated at a follow-up of at least 12 months. All the patients complained of pain and a palpable mass around a previous surgical site at mean 25.1 months (range, 4–72 months) after the initial surgery. Magnetic resonance imaging (MRI) or ultrasound were used to detect the lesion. All the patients underwent surgical excision of foreign body reaction tissue and primary repair using absorbable suture material. After the treatment, the wounds were healed completely in all, and the average FAOS (foot and ankle outcome score) was 91.32 at mean follow-up for 22.4 months. In conclusion, intra-tendinous suture reaction is a rare complication following an Achilles tendon repair using nonabsorbable suture material, but it can be treated adequately with only surgical excision of foreign body reaction tissue and primary repair using absorbable suture material.