Assessing footwear slip-resistance is critical to preventing slip and fall accidents. The STM603 (SATRA Technology) is commonly used to assess footwear friction but its ability to predict human slips while walking is unclear. This study aimed to assess this apparatus’ ability to predict slips across footwear designs and to determine if modifying the test parameters alters predictions. The available coefficient of friction (ACOF) was measured with the device for nine different footwear designs using twelve testing conditions with varying force, speed and shoe angle. The occurrence of slipping and required coefficient of friction was quantified from human gait data including 124 exposures to liquid contaminants. ACOF values varied across the test conditions leading to different slip prediction models. Generally, a larger shoe angle (13°) and higher vertical forces (400 or 500 N) modestly improved predictions of slipping. This study can potentially guide improvements in predictive test conditions for this device. Practitioner Summary: Frictional measures by the STM603 (SATRA Technology) were able to predict human slips under liquid contaminant conditions. Test parameters did have an influence on the measurements. An increased shoe-floor testing angle resulted in better slip predictions than test methods specified in the ASTM F2913 standard.
Protective footwear is necessary for preventing injurious slips and falls in winter conditions. Valid methods for assessing footwear slip resistance on winter surfaces are needed in order to evaluate footwear and outsole designs. The purpose of this study was to utilise a method of testing winter footwear that was ecologically valid in terms of involving actual human testers walking on realistic winter surfaces to produce objective measures of slip resistance. During the experiment, eight participants tested six styles of footwear on wet ice, on dry ice, and on dry ice after walking over soft snow. Slip resistance was measured by determining the maximum incline angles participants were able to walk up and down in each footwear–surface combination. The results indicated that testing on a variety of surfaces is necessary for establishing winter footwear performance and that standard mechanical bench tests for footwear slip resistance do not adequately reflect actual performance. Practitioner Summary: Existing standardised methods for measuring footwear slip resistance lack validation on winter surfaces. By determining the maximum inclines participants could walk up and down slopes of wet ice, dry ice, and ice with snow, in a range of footwear, an ecologically valid test for measuring winter footwear performance was established.