Yun Chen

Ms. Yun Chen

Southeast University, China
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2016 in Journal of Electroanalytical Chemistry
Verified
Journal Article
Closed access
Yun ChenYun Chen
Yun Chen
QLQiwei Li
Qiwei Li
HJHui Jiang
Hui Jiang
XWXuemei Wang
Xuemei Wang

3 February 2015 in Journal of Nanobiotechnology
Verified
Journal Article
Open access
PDF file
WGWei Ge
Wei Ge
YZYuanyuan Zhang
Yuanyuan Zhang
JYJing Ye
Jing Ye
DCDonghua Chen
Donghua Chen
Fawad Ur RehmanFawad Ur Rehman
Fawad Ur Rehman
Xuemei WangXuemei Wang
Xuemei Wang
Tumor-target fluorescence bioimaging is an important means of early diagnosis, metal nanoclusters have been used as an excellent fluorescent probe for marking tumor cells due to their targeted absorption. We have developed a new strategy for facile synthesis of Au/Ce nanoclusters (NCs) by doping trivalent cerium ion into seed crystal growth process of gold. Au/Ce NCs have bright fluorescence which could be used as fluorescent probe for bioimaging. In this study, we synthesized fluorescent Au/Ce NCs through two-step hydrothermal reaction. The concentration range of 25–350 μM, Au/Ce NCs have no obvious cell cytotoxicity effect on HeLa, HepG2 and L02 cells. Furthermore, normal cells (L02) have no obvious absorption of Au/Ce NCs. Characterization of synthesized Au/Ce NCs was done by using TEM, EDS and XPS. Then these prepared Au/Ce NCs were applied for in vitro/in vivo tumor-target bioimaging due to its prolonged fluorescence lifetime and bright luminescence properties. The glutathione stabilized Au/Ce NCs synthesized through hydrothermal reaction possess stable and bright fluorescence that can be readily utilized for high sensitive fluorescence probe. Our results suggest that Au/Ce NCs are useful candidate for in vitro/in vivo tumor bioimaging in potential clinical application.

6 May 2020 in The Analyst
Verified
Journal Article
Closed access
PDF file
Yun ChenYun Chen
Yun Chen
XDXiawei Dong
Xiawei Dong
YZYoukun Zheng
Youkun Zheng
YWYihan Wang
Yihan Wang
ZGZengchao Guo
Zengchao Guo
Xuemei WangXuemei Wang
Xuemei Wang
In this study, we report a facile one-pot chemical etching approach to simply and rapidly prepare gold nanoclusters capped with luminol (Lum-AuNCs) in an alkaline aqueous solution at room temperature. A series of characterization studies have been carried out to explore the morphology, the optical properties and chemical components of Lum-AuNCs. The average diameter of Lum-AuNCs is 1.8 ± 0.3 nm, exhibiting fluorescence near 510 nm upon excitation at 420 nm with a quantum yield of 14.29% and an average fluorescence lifetime of 9.47 ns. On the basis of the ligand-induced etching of glutathione (GSH) to the intermediate (luminol capped gold nanoparticles, abbreviated as Lum-AuNPs), a novel and simple method for the fluorescence determination of GSH has been established. The method displays a good linear response in the range of 0.05–300 μM toward GSH with a limit of detection of 35 nM. This detection strategy with high sensitivity and selectivity facilitates its practical application for the detection of GSH levels in cell extracts. The in vitro cell results illustrate that Lum-AuNCs have good cytocompatibility and can be used to readily differentiate normal cells and tumor cells.

11 February 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Yun ChenYun Chen
Yun Chen
JYJing Ye
Jing Ye
GLGang Lv
Gang Lv
WLWeiwei Liu
Weiwei Liu
HJHui Jiang
Hui Jiang
Xuemei WangXuemei Wang
Xuemei Wang
Accurate diagnosis of cancer cells directly affects the clinical treatment of cancer and can significantly improve the therapeutic effect of cancer patients. Cancer cells have a unique microenvironment with a large amount of peroxide inside, effectively differentiated from relevant microenvironment normal cells. Therefore, designing the high-sensitive probes to recognize and distinguish the special physiological microenvironment of cancer cells can shed light on the early diagnosis of cancers. In this article, we design and construct a fluorescence (FL) contrast agent for cancer cell recognition and imaging analysis. Firstly, luminol-gold NPs (Lum-AuNPs) have been initially built, and then successfully loaded with the fluorescent receptor Chlorin e6 (Ce6) to prepare the luminescent nanoprobes (Ce6@Lum-AuNPs) with green synthesis, i.e., with biocompatible agents and mild temperature. The as-prepared fluorescent Ce6@Lum-AuNPs can efficiently and sensitively realize FL bioimaging of cancer cells. The relevant bio-sensing mechanism pertains to the presence of hypochlorite (ClO−); hydrogen peroxide (H2O2) in cancer cells could readily interact with luminol to produce chemiluminescence, which can activate the Ce6 component to emit near-infrared (NIR) FL. Therefore, this raises the possibility of utilizing the Ce6@Lum-AuNPs as efficient fluorescent nanoprobes for promising cancer early diagnosis and other relevant disease bioanalysis.