Key Laboratory of Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
Mr. Zhengang Li
Key Laboratory of Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
A high-sensitivity differential Helmholtz photoacoustic cell based on multiple reflection was reported, and its performance parameters and gas replacement time were optimized by finite element simulation. To realize the long absorption path of the measured gas, the collimated excitation light was reflected multiple times on the gold-plated wall of the absorption cavity, and the wavelength modulation technology was used to reduce the multiple reflection noise. Additionally, the differential could suppress external co-phase noise and double the photoacoustic signal. When a laser with a central wavelength of 1653 nm was employed as the excitation light source, the minimum detection limit of 177 ppb (signal-to-noise ratio, SNR = 1) for methane was achieved within a detection time of 1 s, and the corresponding normalized noise equivalent absorption coefficient was 4.1×10–10 cm–1WHZ–1/2.
The concentration of trace gases in the atmospheric environment is extremely low, but it has a great impact on the living environment of organisms. Photoacoustic spectroscopy has attracted extensive attention in the field of trace gas detection because of its high sensitivity, good selectivity, and fast response. As the core of a photoacoustic detection setup, the photoacoustic cell has a significant impact on detection performance. To improve detection sensitivity, a sphere-tube coupled photoacoustic cell (STPAC) was developed, which was mainly composed of a diffuse-reflective sphere and an acoustic resonance tube. Modulated light was reflected multiple times in the sphere to increase optical path, and photoacoustic (PA) signals were further amplified by the tube. Based on STPAC, a PA gas detection setup was built with a laser diode (LD) at 450 nm as the light source. The experimental results showed that the minimum detection limit (noise equivalent concentration, NEC) of NO2 was ~0.7 parts per billion (ppb). Compared with the T-type PA cell (TPAC) in which the modulated light passed through the sphere, the signal-to-noise ratio of STPAC was increased by an order of magnitude at the same concentration of the NO2 sample.
A highly sensitive differential Helmholtz photoacoustic sensor with active noise reduction was reported. Coupled to one cavity of the photoacoustic cell, an intensity-modulated excitation light would reflect multiple times to produce photoacoustic signal, and meanwhile cause the solid-state photoacoustic effect forming differential mode noise with the frequency same as the photoacoustic signal, which could not be suppressed by conventional differential technology. Wavelength modulation technology is a splendid method to restrain this effect, which is not suitable for light sources with not adjustable wavelength. To suppress this kind of noise, an intensity-modulated compensation light was coupled to another cavity, whose central wavelength was at the non-absorption line of the measured gas. The compensation light was of the same frequency, phase, and power as the excitation light, by which the solid-state photoacoustic effects were produced to form destructive interference called active noise reduction. The experiment results showed that the active noise reduction significantly improved the signal-to-noise ratio and signal-to-background ratio. Compared with the differential, the differential with active noise reduction improved signal-to- noise ratio by about 1.2 times and signal-to-background ratio by about 9.4 times. When low-power near-infrared lasers were employed as the two light sources, the minimum detection limits for acetylene and methane reached 21 and 200 ppb, respectively.
A parabolic mirror cavity-enhanced Raman spectroscopy (PM-CERS) method was reported, utilizing a combined optical path of a parabolic mirror and a multi-pass cell. In this setup, the focal point of the parabolic mirror is aligned with the laser convergence center of the multi-pass cell. This method achieved high excitation intensity at the focal point and broadened the collection range of Raman scattering signals, thus significantly improving both the excitation and collection efficiency of Raman signals. Additionally, the structure of the system was simplified through the integrated design of the collection cavity and sample cell. Nitrogen, oxygen, water vapor, and carbon dioxide could be detected in the air within an exposure time of just 0.5 s, achieving the limits of detection at the ppm level. Compared to the conventional multi-pass cell, the signal intensity and signal-to-noise ratio were each enhanced by approximately 5.6-fold, further demonstrating the excellent potential application in trace gas detection.
The precise detection of trace gases in the atmosphere is vital for both environmental preservation and human health. Addressing the inherent challenges in enhancing the sensitivity of photoacoustic spectroscopy, a highly sensitive photoacoustic gas detection method utilizing a near-concentric cavity was proposed. By constructing a near-concentric optical cavity, laser reflections within the photoacoustic cell were substantially amplified, resulting in enhanced sensitivity of photoacoustic signal detection. Additionally, to align with the optical path characteristics of the near-concentric cavity, a miniaturized dumbbell-like photoacoustic cell was designed. Characterized by its high-frequency resonance, this design effectively mitigated background noise while maintaining a high sound pressure level. Experimental results demonstrated a remarkable enhancement in both signal intensity and signal-to-noise ratio by factors of 22.06 and 21.26, respectively, compared to traditional excitation methods. According to the 1σ standard, with a laser power of 21 mW, the setup achieved a detection limit of 10.15 ppb for NO2. The corresponding normalized noise equivalent absorption was calculated to be 2.84 × 10−9 cm−1WHz−1/2, with a gas consumption rate of merely 15.19 mL.