The barrier fluid system in subsea boosting pumps primarily serves to seal and cool the pumps, representing a critical auxiliary system in subsea oil and gas development. Throughout their entire service life, these pumps experience both steady-state and transient operating conditions, making the monitoring of key parameters in the barrier fluid system essential. However, existing sensor configurations are relatively limited, hindering comprehensive monitoring of various components of the system, which constrains performance evaluation and optimal design. To address the sealing and cooling requirements of subsea boosting pumps, this paper establishes a system-level simulation model of the barrier fluid system based on the AMESim 2021.1 platform. The model captures the flow and pressure relationships among different components and incorporates the pump’s cooling circuit to investigate the thermal management efficiency of the barrier fluid system. Furthermore, integrated control algorithms enable automatic valve operation. The model’s accuracy is validated against measured data, and it can be used for parametric optimization to improve design and enhance overall system performance. Based on the analysis results, the model can identify optimal parameters for the subsea boosting pump barrier fluid system, providing a theoretical foundation for preventing potential issues in subsea boosting operations.
The optimization study of gold wire bonding process between quartz glass gold-plated electrodes and metal base pins was carried out by partial factorial DOE method. The multiple linear regression equation corresponding to the bond tension value and the influence factor was obtained by regression fitting. The study found that the significant degree of influence of the bonding parameters on the bonding tension value was in the following order: ultrasonic time>bonding pressure>bonding temperature>ultrasonic power. The optimized parameter combination was as follows: the ultrasonic power was 100mW, the ultrasonic time was 25ms, the bonding pressure was 25cN, and the bonding temperature was 150℃. The ultrasonic power had a significant interaction with the bonding temperature. When the bonding temperature was at a low level, the bonding tension value increased with the increase of the ultrasonic power. When the bonding temperature was at a high level, the bond tension value decreased with the increase of the ultrasonic power. After verification, the bonding tension was greatly improved using the optimized bonding process parameters.