ZHONGFENG ZHU

Dr. ZHONGFENG ZHU


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Journal of Composites for Construction
Verified
Journal Article
Closed access
ZHONGFENG ZHUZHONGFENG ZHU
ZHONGFENG ZHU
Wen-Wei WangWen-Wei Wang
Wen-Wei Wang
KHKent A. Harries
Kent A. Harries
YZYu-Zhou Zheng
Yu-Zhou Zheng
Carbon fiber–reinforced polymer (CFRP) grid–reinforced engineered cementitious composites (ECC) have been developed as an alternative to epoxy resin–based FRP plates for the strengthening of concrete structures. To broaden the application of this new composite material for seismic retrofit and strengthening of reinforced concrete elements, an experimental study, including three nonreinforced ECC plates and 30 CFRP grid–reinforced ECC (CFRP-ECC) hybrid plates, was conducted to investigate their mechanical performance under both monotonic and cyclic uniaxial tensile loads. The stiffness of the internal CFRP grid and loading scheme were the two primary test variables. Test results showed that all CFRP-ECC plates failed with a dominate crack in the ECC matrix and rupture of the internal CFRP grid. The envelopes of the cyclic tensile stress–strain curves followed the static stress–stain curves regardless of the cyclic loading scheme adopted. A nonlinear stress–strain model is proposed to model the unloading/reloading paths of CFRP-ECC plates under cyclic uniaxial tensile loading.

1 February 2022 in Journal of Composites for Construction
Verified
Journal Article
Closed access
PDF file
ZHONGFENG ZHUZHONGFENG ZHU
ZHONGFENG ZHU
Wen-Wei WangWen-Wei Wang
Wen-Wei Wang
YHYing-Xin Hui
Ying-Xin Hui
SHShao-Wei Hu
Shao-Wei Hu
GMGuang-Yu Men
Guang-Yu Men
HHHui Huang
Hui Huang
Using fiber-reinforced polymer (FRP) grid-reinforced engineered cementitious composites (ECC) for strengthening reinforced concrete columns and beams has been stirring structural research interest in recent years. The objective of this research was to extend the application of this technique, using carbon-fiber-reinforced polymer (CFRP). The authors used compression tests on short concrete columns strengthened with CFRP-ECC to investigate the mechanical behavior of strengthened columns by considering the unconfined concrete strength and reinforcement layers of CFRP grid. Test results show that the failure mode of most strengthened columns lies in the rupture of the embedded CFRP grid. The lateral strains corresponding to peak stresses were close, and their average value was almost equal to the ultimate axial tensile strain of the CFRP-ECC. Meanwhile, with an increased number of reinforcement layers, the peak stress and strain of the strengthening columns increased significantly for low-strength core concrete. However, there was no significant enhancement for the high-strength core concrete. In addition, the cracking stress of CFRP-ECC had obvious effects on the yielding stress, peak stress, peak strain, and the axial–lateral strain relationship. Most importantly, a better understanding of the stress–strain relationship for CFRP-ECC confined columns was established, and the feasibility of this model was verified by the analysis results.

11 September 2022 in Construction and Building Materials
Verified
Journal Article
Closed access
ZHONGFENG ZHUZHONGFENG ZHU
ZHONGFENG ZHU
Madura PathirageMadura Pathirage
Madura Pathirage
Wen-Wei WangWen-Wei Wang
Wen-Wei Wang
MTMatthew Troemner
Matthew Troemner
GCGianluca Cusatis
Gianluca Cusatis

23 March 2022 in Polymers
Verified
Journal Article
Open access
PDF file
GGGuoqiang Gong
Guoqiang Gong
Menghuan GUOMenghuan GUO
Menghuan GUO
Yingwu ZhouYingwu Zhou
Yingwu Zhou
SZShuyue Zheng
Shuyue Zheng
Biao HuBiao Hu
Biao Hu
ZHZhenyu Huang
Zhenyu Huang
Limestone calcined clay cement (LC3) is successfully used to fabricate engineered cementitious composites (ECC) exhibiting tensile strength σtu of 9.55 ± 0.59 MPa or tensile strain capacity εtu of 8.53 ± 0.30%. The high tensile strength of the composites is closely related to the improvement of fiber/matrix interfacial bond strength, and the high ductility is attributed to the enhancement of fiber dispersion homogeneity. For the case of ECC incorporating 50% LC3, the reduction of initial cracking stress σtc that favors the growth of the crack in a controlled manner also contributes to the improvement of strain hardening behavior. The composition analysis indicates that carboaluminates and additional hydration products including C-(A)-S-H and ettringite are generated, which contributes to the densification of the microstructure of the ECC matrix. The pore structure is thus remarkably refined. Besides, when ordinary Portland cement (OPC) is partly replaced by LC3, the consumed energy and equivalent CO2 emission decrease, especially the equivalent CO2 emission with the reduction ratio attaining 40.31%. It is found that ECC using 35% LC3 exhibits the highest mechanical resistance and ECC incorporating 50% LC3 shows the highest ductility from the environmental point of view.

8 April 2022 in Construction and Building Materials
Verified
Journal Article
Closed access
YXYan-Jie Xue
Yan-Jie Xue
Wen-Wei WangWen-Wei Wang
Wen-Wei Wang
Xiao TanXiao Tan
Xiao Tan
YHYing-Xin Hui
Ying-Xin Hui
Jun TianJun Tian
Jun Tian
ZHONGFENG ZHUZHONGFENG ZHU
ZHONGFENG ZHU

16 June 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Yingwu ZhouYingwu Zhou
Yingwu Zhou
WGWenhui Guo
Wenhui Guo
SZShuyue Zheng
Shuyue Zheng
FXFeng Xing
Feng Xing
Menghuan GUOMenghuan GUO
Menghuan GUO
ZHONGFENG ZHUZHONGFENG ZHU
ZHONGFENG ZHU
In this study, sustainable engineered cementitious composites (ECC) exhibiting high tensile strength as well as high tensile strain capacity were successfully developed by incorporating polyethylene (PE) fiber, local recycled fine aggregate (RFA), and limestone calcined clay cement (LC3). The improvement in tensile strength and tensile ductility was attributed to the self-cementing properties of RFA as well as the pozzolanic reaction between calcined clay and cement. Carbonate aluminates were also generated owing to the reaction between calcium carbonate in limestone and the aluminates in both calcined clay and cement. The bond strength between fiber and matrix was also enhanced. At the age of 150 days, the tensile stress-strain curves of ECC containing LC3 and RFA shifted from a bilinear model to a trilinear model, and the hydrophobic PE fiber exhibited hydrophilic bonding performance when embedded in RFA-LC3-ECC matrix, which could be explained by the densified cementitious matrix as well as the refined pore structure of ECC. Moreover, the substitution of ordinary Portland cement (OPC) by LC3 resulted in energy consumption and equivalent CO2 emission reduction ratios of 13.61% and 30.34%, respectively, when the replacement ratio of LC3 is 35%. Therefore, PE fiber-reinforced RFA-LC3-ECC demonstrates excellent mechanical performance as well as considerable environmental benefits.