Background and Objectives: To compare the oral-health-related quality of life (OHRQoL) outcomes between patients treated with modified Ni-Ti spring-based alignment appliances or conventional fixed appliances using the Oral Health Impact Profile 14 (OHIP-14), as well as the levels of satisfaction with the appliance appearance, treatment progress, and outcomes. Materials and Methods: Thirty-six patients (11 males, 25 females) were randomly divided into two groups: either the modified aligner appliance with Ni-Ti springs group (MAA) or the traditional fixed appliances group (FA). The allocation ratio was 1:1, and the randomization process was carried out by an independent investigator not involved in this study. Mild crowding cases were included in this study. The OHRQoL of patients was evaluated using the short-form Oral Health Impact Profile (OHIP-14) at five time points: before the treatment commencement (T0); 2 weeks (T1), 1 month (T2), and 2 months (T3) after the treatment initiation; and post-treatment (T4). The visual analog scale (VAS) was used to evaluate the patient satisfaction. Blinding was performed only during the outcomes assessment. Results: This randomized controlled trial had no dropouts, and the demographic characteristics of the groups were comparable. The MAA group experienced significantly greater functional limitations compared with the FA group at all three evaluation time points (T1, T2, and T3), as evidenced by the statistically significant p-values (p = 0.004, p = 0.001, and p < 0.001, respectively). The psychological disability in the MAA group was significantly lower than in the FA group at both T2 (p = 0.005) and T3 (p = 0.003). The patient satisfaction with the appliance appearance was significantly higher in the MAA group than in the FA group (p = 0.002). Conclusions: The OHRQoL improved in both the modified aligner appliance with Ni-Ti springs and fixed appliance groups after the treatment. Moreover, the functional limitations during the treatment were less severe in the FA group, while the psychological disability was lower, and the patient satisfaction with the appliance appearance was higher in the MAA group.
16 October 2025 in European Journal of Orthodontics
Background: Clear aligners represent a modern alternative to traditional fixed orthodontic appliances, offering aesthetic and removable treatment options. However, variability in clinical outcomes and treatment protocols has led to inconsistent evidence regarding their effectiveness and stability. Objectives: To systematically review and synthesize available evidence from randomized and non-randomized trials comparing the quality and stability of orthodontic treatment outcomes using clear aligners versus fixed appliances. Search methods: A comprehensive literature search was conducted across seven databases (PubMed®, Google™ Scholar, Embase®, Scopus®, Web of ScienceTM, the Cochrane Central Register of Controlled Trials, ProQuest) up to February 2025, identifying relevant clinical trials assessing treatment outcomes with clear aligners and fixed appliances. Selection criteria: Randomized controlled trials and non-randomized clinical trials comparing orthodontic treatment outcomes of clear aligners versus conventional fixed appliances in patients undergoing orthodontic treatment were included. Data collection and analysis: Two reviewers independently screened titles, abstracts, and full texts, extracted data, and assessed the risk of bias for each included study. The Cochrane Risk of Bias tool (RoB2 tool) was used for randomized controlled trials, while the ROBINS-I tool was applied for non-randomized studies. When appropriate, random-effects meta-analyses were performed. The certainty of the evidence for each outcome was evaluated using the GRADE approach. Results: Fifteen trials involving 1084 patients were included. The risk of bias varied across studies. No significant differences were found in treatment quality or duration between clear aligners and fixed appliances in non-extraction cases, although sensitivity analyses suggested shorter treatment duration with clear aligners. In extraction cases, fixed appliances provided superior treatment quality, attributed to enhanced control of tooth movements. Limited evidence indicated similar post-treatment stability between the two interventions. However, study heterogeneity and short follow-up durations limited the strength of conclusions. Conclusions: Both clear aligners and fixed appliances effectively achieve orthodontic treatment goals. Case complexity and patient compliance should guide appliance selection. Further large-scale, well-designed trials with long-term follow-up are necessary to define comparative outcomes. Registration: The protocol for this review was registered with PROSPERO (CRD420251072157) during its initial stages.
This study aimed to use cone-beam computed tomography (CBCT) imaging to assess maxillary sinus volume and related measurements in different sagittal skeletal classes. Sixty CBCT images of adult patients aged between 18 and 25 years were collected and divided into three groups based on the ANB angle value: Class I (ANB = 0–4 degrees), Class II (ANB > 4 degrees), and Class III (ANB < 0 degrees). Maxillary sinus volume, surface area, width, depth, and height measurements were performed using Mimics Research TM software version 21.0. The maxillary sinus measurements were compared among the three skeletal groups. A total of 60 patients, with a mean age of 21.10 ± 2.00 years (ranging from 18 to 25 years), met the inclusion criteria. Statistical analysis revealed no significant difference in maxillary sinus measurements between the right and left sides (P > 0.05). Therefore, the mean value of bilateral measurements was used for subsequent analysis. No significant differences were observed in maxillary sinus volume, surface area, or height among the three skeletal classes (P > 0.05). However, the Class I group exhibited significantly greater maxillary sinus width and depth compared to Class III (P < 0.05).
24 May 2022 in Journal of the World Federation of Orthodontists
Background and objectives A modified aligner appliance with nickel-titanium springs (MAA) is a relatively new appliance that has not received extensive attention in orthodontics. This study evaluated the patient-reported outcomes when orthodontic treatment was provided using a modified aligner appliance to treat mild lower incisor crowding. Materials and methods This prospective cohort study consisted of 42 patients (11 males and 31 females; mean age 21.69 ± 2.56 years) with mild crowding. Twenty-one patients were treated using a modified aligner with nickel-titanium springs, while the remaining patients were treated with a conventional fixed orthodontic appliance (FA). Patient responses regarding pain, discomfort, and difficulty in chewing, swallowing, and speaking were recorded using a visual analog scale (VAS) at six assessment times: 24 hours (T1), two days (T2), three days (T3), two weeks (T4), one month (T5), and two months (T6) after appliance application. Results The mean perceived pain and discomfort levels were generally lower in the traditional fixed appliance (FA) group than the modified aligner appliance with nickel-titanium springs group at most assessment times. However, no statistically significant differences were found between the two groups. Chewing difficulty levels were similar between the two groups with no substantial differences. Swallowing and speech difficulty were significantly higher in the MAA group compared to the FA group during the first two days of treatment (P < 0.008). Conclusions Patients using both types of orthodontic appliances experienced temporary discomfort, including pain and difficulty chewing. While the modified aligners appliance with nickel-titanium springs caused additional challenges with swallowing and speaking, these issues were resolved over time, allowing patients to adjust to the treatment.