Ziyad Mohammed Aloqalaa

Dr. Ziyad Mohammed Aloqalaa

King Saud University, Riyadh, Ar Riyāḑ, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
OAOmar Altwijri
Omar Altwijri
RAReem Sayer Alanazi
Reem Sayer Alanazi
AAAdham Aleid
Adham Aleid
KAKhalid Alhussaini
Khalid Alhussaini
ZAZiyad Mohammed Aloqalaa
Ziyad Mohammed Aloqalaa
ASAli saad
Ali saad
This study introduces a novel deep-learning methodology that is customized to automatically diagnose Alzheimer’s disease (AD) through the analysis of MRI datasets. The process of diagnosing AD via the visual examination of magnetic resonance imaging (MRI) presents considerable challenges. The visual diagnosis of mild to very mild stages of AD is challenging due to the MRI similarities observed between a brain that is aging normally and one that has AD. The detection of AD with extreme precision is critical during its early stages. Deep-learning techniques have recently been shown to be significantly more effective than human detection in identifying various stages of AD, enabling early-stage diagnosis. The aim of this research is to develop a deep-learning approach that utilizes pre-trained convolutional neural networks (CNNs) to accurately detect the severity levels of AD, particularly in situations where the quantity and quality of available datasets are limited. In this approach, the AD dataset is preprocessed via a refined image processing module prior to the training phase. The proposed method was compared to two well-known deep-learning algorithms (VGG16 and ResNet50) using four Kaggle AD datasets: one for the normal stage of the disease and three for the mild, very mild, and moderate stages, respectively. This allowed us to evaluate the effectiveness of the classification results. The three models were compared using six performance metrics. The results achieved with our approach indicate an overall detection accuracy of 99.3%, which is superior to the other existing models.

28 July 2022 in Crystals
Verified
Journal Article
Open access
PDF file
ZAZiyad Mohammed Aloqalaa
Ziyad Mohammed Aloqalaa
Fused Deposition Modeling (FDM) is one of the most popular three dimensional (3D) printing techniques especially among researchers. Recently, FDM has been widely developed and improved in many areas. One of these improvements is the introduction of electrically conductive filaments. In general, conductive filaments are usually made of conductive polymer composites. These composites consist of a thermoplastic material blended with carbon-based materials. The quantity of commercially available conductive filaments has grown significantly in recent years. This paper presents a sample of currently available conductive filaments (eight filaments were chosen). These samples were compared by measuring resistance value and highlighting resulted defects of each sample. Additionally, this paper searched and reviewed articles that used conductive FDM filaments in medical applications. These articles were collected and summarized in terms of name of filaments were used, the specific function of the printed conductive object, and name of the printer used to print the conductive object. In conclusion, the main purpose of this project is to facilitate the work of future medical researchers who would like to use commercially available conductive FDM filaments.

1 January 2023 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
ZAZiyad Mohammed Aloqalaa
Ziyad Mohammed Aloqalaa
Cardiovascular diseases (CVDs) are the leading cause of death worldwide. Therefore, the ability to monitor electrocardiogram (ECG) in the long term could save patients’ lives by allowing early diagnosis and intervention. Dry electrodes are the best option to accomplish this task. 3D printing is one of the popular techniques currently used to construct dry electrodes. This project designs, builds, tests, and compares 3D printed ECG electrodes using four commercially available electrically conductive polylactic acid‐based fuzed deposition modeling filaments. Also, this project uses these printed electrodes to acquire ECG raw signals. Then it compares these signals by calculating their signal‐to‐noise ratio (SNR) and their ability to measure heart rate using the Pan–Tompkins algorithm. Also, the resistance of these printed electrodes is measured. In conclusion, all printed electrodes in this experiment show acceptable efficiency with SNR values equal to or larger than 18.89 dB, and these electrodes prove their ability to measure heart rate using the Pan–Tompkins algorithm. However, according to the results of this experiment, one commercially available brand (Proto‐Pasta) is more favorable to use. Proto‐Pasta has the highest SNR value (20.71 dB), the second lower resistance values (∼ from 600Ωto 2 kΩ), the lowest 60 Hz powerline and low‐frequency noise, the most accurate printed electrodes (the printed electrodes have less shape deformity compared to other brands), and no any noticeable physical malfunction (no knops break from the electrodes during the test process).

11 July 2022 in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Verified
Conference Paper
Open access
ZAZiyad Mohammed Aloqalaa
Ziyad Mohammed Aloqalaa
The most commonly used bio-potential electrodes are silver/silver chlorides gel-electrodes (Ag/AgCl electrodes). However, wet electrodes are not suited for daily usage and long-term monitoring. Dry electrodes are the best choice for long-term measurements. Dry electrodes can be fabricated using various methods and materials; one of these methods is three dimensional (3d) printing. 3d printing is a cost-effective method and can be easily used in mass production. This paper will present 3d printed bio-potential dry electrodes using five different commercially available fused deposition modeling (FDM) electrically conductive filaments. Then, these printed electrodes will be tested and validated using electrocardiogram (ECG) portable acquisition system. Three out of five filaments were printed successfully. Collected ECG data from these electrodes showed acceptable quality with Signal to Noise Ratios (SNRs) ranging around 20 dB when compared with wet electrodes collected raw data as a reference. In conclusion, this study designed and printed a 100% 3d printed electrodes from three different FDM filaments which could be used efficiently for ECG signal monitoring in resting position.

15 March 2025 in Processes
Verified
Journal Article
Open access
PDF file
MAMohammed Almijalli
Mohammed Almijalli
FAFaten A. Almusayib
Faten A. Almusayib
GAGhala F. Albugami
Ghala F. Albugami
ZAZiyad Mohammed Aloqalaa
Ziyad Mohammed Aloqalaa
OAOmar Altwijri
Omar Altwijri
ASAli saad
Ali saad
The automatic detection of objects in medical photographs is an essential component of the diagnostic procedure. The issue of early-stage brain tumor detection has progressed significantly with the use of deep learning algorithms (DLA), particularly convolutional neural networks (CNN). The issue lies in the fact that these algorithms necessitate a training phase involving a large database over several hundred images, which can be time-consuming and require complex computational infrastructure. This study aimed to comprehensively evaluate a proposed method, which relies on an active contour algorithm, for identifying and distinguishing brain tumors in magnetic resonance images. We tested the proposed algorithm using 50 brain images, specifically focusing on glioma tumors, while 2000 images were used for DLA from the BRATS Challenges 2021. The proposed segmentation method is made up of an active contour algorithm, an anisotropic diffusion filter for pre-processing, active contour segmentation (Chan-Vese), and morphologic operations for segmentation refinement. We evaluated its performance using various metrics, such as accuracy, precision, sensitivity, specificity, Jaccard index, Dice index, and Hausdorff distance. The proposed method provided an average of the first six performance metrics of 0.96, which is higher than most classical image segmentation methods and was comparable to the deep learning methods, which have an average performance score of 0.98. These results indicate its ability to detect brain tumors accurately and rapidly. The results section provided both numerical and visual insights into the similarity between segmented and ground truth tumor areas. The findings of this study highlighted the potential of computer-based methods in improving brain tumor identification using magnetic resonance imaging. Future work must validate the efficacy of these segmentation approaches across different brain tumor categories and improve computing efficiency to integrate the technology into clinical processes.

27 March 2026 in Journal of Materials Science: Materials in Electronics
Verified
Journal Article
Closed access
PDF file
ZAZiyad Mohammed Aloqalaa
Ziyad Mohammed Aloqalaa
AAAbdulsalam A. Al-Tamimi
Abdulsalam A. Al-Tamimi
SASoliman A. Alhudaithy
Soliman A. Alhudaithy
FFFaisal S. Fakhouri
Faisal S. Fakhouri
OAOmar Alageel
Omar Alageel
AFAbdulaziz S. Fakhouri
Abdulaziz S. Fakhouri