Ahmad O. Alokaily

Dr. Ahmad O. Alokaily

Biomedical Engineering, King Saud University/ College of Applied Medical Sciences, Riyadh, Ar Riyāḑ, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2024 in IEEE Access
Verified
Journal Article
Open access
ARAhmad Zahid Rao
Ahmad Zahid Rao
SSSaba Shahid Siddique
Saba Shahid Siddique
DMDanish Mujib
Danish Mujib
MHMuhammad Abul Hasan
Muhammad Abul Hasan
AAAhmad O. Alokaily
Ahmad O. Alokaily
TTTayyaba Tahira
Tayyaba Tahira
Advanced assistive devices developed for activities of daily living use machine learning (ML) for motion intention detection using wearable sensors. Trunk assistive devices provide safety, balance, and independence for wheelchair-bound individuals who spend prolonged hours in sitting positions. We used ML for trunk movement intention detection with a trunk orthosis. Sensor fusion technique with four electromyography (EMG) and one inertial measurement unit (IMU) sensor signals are used to develop a three-level classification system. Forty participants engaged in seated trunk movement trials wearing the orthosis. The trials comprised 30 movements involving trunk flexion/extension, lateral bending, and axial rotation. The wrapper method was used to reduce essential EMG features. Ensemble (ES), k-nearest neighbors (KNN), and support vector machine ML classifiers were used. Twenty-six features (five EMG for each of four muscles and six for IMU) were used to develop ten individual ML models, resulting in an average accuracy of 95.44%. Eight models achieved the highest accuracy with the ES and two with KNN. The models were then cascaded to form a trunk motion detection system that achieved a test accuracy of 87.0%. The promising result of this study can be implemented for trunk motion recognition with active trunk orthosis.

18 March 2024 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
AAAlaa M Albishi
Alaa M Albishi
SASaja A. Alhadlaq
Saja A. Alhadlaq
RARahaf T. Altowairqi
Rahaf T. Altowairqi
MAMohammed F. Alharbi
Mohammed F. Alharbi
AAAbdulrahman M. Alsubiheen
Abdulrahman M. Alsubiheen
AAAhmad O. Alokaily
Ahmad O. Alokaily
Research has demonstrated the benefits of transcranial magnetic stimulation (TMS) in rehabilitation. TMS has been widely used in clinical and research settings for individuals with and without neurological dysfunctions. Therefore, understanding the knowledge and attitudes of rehabilitation specialists regarding TMS is crucial for its application. To our knowledge, no such studies have previously been conducted in the rehabilitation field. Therefore, this study is the first to assess rehabilitation specialists’ knowledge of and attitudes toward TMS. An observational cross-sectional study using a self-administered online survey was conducted among 102 rehabilitation specialists to assess their knowledge and attitudes regarding TMS application in rehabilitation sciences. Descriptive and inferential statistics were used to describe the knowledge and attitudes of rehabilitation specialists toward TMS and examine the impact of different factors such as gender, education level, acceptability, and practice on these outcomes. Rehabilitation specialists who participated in this study showed a limited level of general knowledge of TMS in rehabilitation (7.81 ± 6.20, 37.19%). However, a significant association between educational levels and knowledge was found. Higher knowledge scores were observed for specialists with post-graduate degrees compared to those with only a bachelor’s degree. Moreover, knowledge level, experience, and availability of TMS equipment in the workplace led to a positive attitude toward TMS among rehabilitation specialists. A low knowledge level among rehabilitation specialists was attributed to their level of education. Nevertheless, specialists showed an overall positive attitude toward TMS. Therefore, customized medical education is necessary to incorporate TMS theory and applications into neuroscience and rehabilitation courses for rehabilitation specialists as it holds significant promise as a therapeutic tool.

3 March 2025 in Frontiers in Aging Neuroscience
Verified
Journal Article
Open access
PDF file
MMMuhammad Danish Mujib
Muhammad Danish Mujib
ARAhmad Zahid Rao
Ahmad Zahid Rao
MHMuhammad Fahim Ul Haque
Muhammad Fahim Ul Haque
AAAhmad O. Alokaily
Ahmad O. Alokaily
SHSyeda Sehar Hussain
Syeda Sehar Hussain
MHMuhammad Abul Hasan
Muhammad Abul Hasan
Introduction: Alzheimer’s disease (AD) affects 50 million individuals worldwide, a number projected to triple by 2050. Due to discomfort through electrical and magnetic neuromodulation technologies, this is the first study to propose the potential of auditory binaural beat (BB) stimulation at an alpha frequency (10 Hz) for enhancing cognitive and neurological outcomes in AD patients.Methods: Twenty-five patients were divided into the experimental-Group (n = 15) and control-Group (n = 10). Psychometric and neurological assessments were conducted Pre-Treatment (Day 1) and Post-Treatment (Day 14) following consecutive days of binaural beats (BB) or auditory tone stimulation administered from Day 2 to Day 13.Results: A two-way ANOVA revealed a significant main effect of group (F = 6.087, p = 0.016) and session (F = 3.859, p = 0.024) on MMSE scores, with the experimental group showing significant improvement in MMSE scores (t = 7.33, p = 0.00000012) compared to the control group (p = 0.2306). Paired t-tests revealed a significant reduction in depression scores (DASS-21, t = 1.701, p = 0.0253) in the experimental group, while no significant improvements were noted in the control group. EEG recordings revealed significant changes in α-band, β-band, and γ-band power (p < 0.05). Moreover, The correlation between EEG bands and MMSE subparts showed that increased θ-band power in the experimental group was positively correlated (p < 0.05) with the frontal region during language tasks and in the frontal and central regions during registration and orientation tasks, indicating potential neurocognitive benefits.Discussion: The results of this research imply that BB stimulation has untapped potential as a non-invasive therapy for patients with AD, hence there is the need for further studies to manage the dementia epidemic.

1 August 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
ARAhmad Zahid Rao
Ahmad Zahid Rao
DMDanish Mujib
Danish Mujib
MHMuhammad Abul Hasan
Muhammad Abul Hasan
AAAhmad O. Alokaily
Ahmad O. Alokaily
TTTayyaba Tahira
Tayyaba Tahira
Saad QaziSaad Qazi
Saad Qazi
The chair-mounted passive trunk orthosis (CMPTO) is designed to enhance wheelchair safety for individuals with dystrophinopathy during their daily activities. Given the disease’s progressive nature, it is crucial to ensure that assistive devices are carefully evaluated to prevent overexertion. This study aims to assess the CMPTO’s user experience and its impact on fatigue-related psychophysiological measurements. We conducted electromyography (EMG) evaluations of four trunk muscles and assessed perceived exertion using the Borg CR-10 scale in 40 healthy subjects while they performed seated maximal reaching tasks with the CMPTO. Additionally, fifteen dystrophinopathy patients evaluated the CMPTO for usability with the System Usability Scale. Paired t-tests were employed to compare the median frequency (MDF) of EMG signals, the Wilcoxon signed-rank test for evaluating exertion, and the Mann–Whitney U test to compare the usability reported by patients to those of healthy subjects. The 4-way ANOVA revealed that MDF patterns were significantly influenced by task orientation for each muscle. The CMPTO did not cause a significant reduction in the MDF. Tasks requiring greater trunk rotation were perceived as more exhaustive. Patients reported acceptable usability with the CMPTO, with scores higher than those of healthy subjects. The CMPTO’s usability was comprehensively evaluated in both healthy subjects and patients with dystrophinopathy. Our findings indicate that the CMPTO can be safely used by individuals with dystrophinopathy as an assistive device to improve seated comfort and functional abilities.

9 September 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AAAhmed A Aldohbeyb
Ahmed A Aldohbeyb
AAAhmad O. Alokaily
Ahmad O. Alokaily
Pyramidal neurons and interneurons play critical roles in regulating the neuronal activities in the mammalian cortex, where they exhibit different firing patterns. Pyramidal neurons mainly exhibit regular-spiking firing patterns, while interneurons have fast-spiking firing patterns. Cortical neurons have distinct action potential onset dynamics, in which the evoked action potential is rapid and highly variable. However, it is still unclear how cortical regular-spiking and fast-spiking neurons discriminate between different types of stimuli by changing their action potential onset parameters. Thus, we used intracellular recordings of regular-spiking and fast-spiking neurons, taken from layer 2/3 in the somatosensory cortex of adult mice, to investigate changes in the action potential waveform in response to two distinct stimulation protocols: the conventional step-and-hold and frozen noise. The results show that the frozen noise stimulation paradigm evoked more rapid action potential with lower threshold potential in both neuron types. Nevertheless, the difference in the action potential rapidity in response to different stimuli was significant in regular-spiking pyramidal neurons while insignificant in fast-spiking interneurons. Furthermore, the threshold variation was significantly higher for regular-spiking neurons than for fast-spiking neurons. Our findings demonstrate that different types of cortical neurons exhibit various onset dynamics of the action potentials, implying that different mechanisms govern the initiation of action potentials across cortical neuron subtypes.

29 May 2025 in Healthcare
Verified
Journal Article
Open access
PDF file
AAAlaa M Albishi
Alaa M Albishi
AAAhmad O. Alokaily
Ahmad O. Alokaily
MAMadhawi K. Altaib
Madhawi K. Altaib
.A.Mohammed ALHarbi
.Mohammed ALHarbi
AAAhmed A Aldohbeyb
Ahmed A Aldohbeyb
Background: Transcranial direct current stimulation (tDCS) has exhibited potential in augmenting motor functions, neuroplasticity, and cognitive abilities within neurological rehabilitation contexts. Despite these promising outcomes, the utilization of tDCS in both research and clinical environments in Saudi Arabia remains relatively unexplored. Objective: This study aims to evaluate the knowledge, attitudes, and motivations of rehabilitation specialists in Saudi Arabia concerning tDCS. Methods: A cross-sectional observational study was conducted through an online questionnaire, involving 112 registered rehabilitation professionals. Results: While 58% of respondents acknowledged tDCS as a therapeutic tool, the overall knowledge level was modest, with a mean score of 3.0 ± 2.7 out of 9. Enhanced levels of knowledge were associated with individuals holding doctoral degrees (p = 0.02) and those with international training exposure (p = 0.03). Despite the limited knowledge base, an overwhelming 94.64% of participants displayed a neutral to positive attitude towards tDCS, with 52.7% recognizing its potential efficacy in neurological recovery. Principal obstacles to implementation included safety-related concerns (21.4%) and the need for specialized training (23.3%). Conclusions: Rehabilitation specialists in Saudi Arabia generally hold a favorable view of tDCS and demonstrate an eagerness to pursue further training. The results underscore the imperative for enhanced educational initiatives and practical training to address knowledge deficiencies and facilitate the seamless integration of tDCS into clinical routines. The implementation of structured training programs could not only reinforce adoption rates but also optimize the role of tDCS within rehabilitation.