Abdul Rehman El Bsat

Mr. Abdul Rehman El Bsat


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
Abdul Rehman El BsatAbdul Rehman El Bsat
Abdul Rehman El Bsat
ESElie Shammas
Elie Shammas
DADaniel Asmar
Daniel Asmar
GSGeorge E. Sakr
George E. Sakr
KZKinan G. Zeno
Kinan G. Zeno
JGJoseph G Ghafari
Joseph G Ghafari
The superimposition of sequential radiographs of the head is commonly used to determine the amount and direction of orthodontic tooth movement. A harmless method includes the timely unlimited superimposition on the relatively stable palatal rugae, but the method is performed manually and, if automated, relies on the best fit of surfaces, not only rugal structures. In the first step, motion estimation requires segmenting and detecting the location of teeth and rugae at any time during the orthodontic intervention. Aim: to develop a process of tooth segmentation that eliminates all manual steps to achieve an autonomous system of assessment of the dentition. Methods: A dataset of 797 occlusal views from photographs of teeth was created. The photographs were manually semantically segmented and labeled. Machine learning methods were applied to identify a robust deep network architecture able to semantically segment teeth in unseen photographs. Using well-defined metrics such as accuracy, precision, and the average mean intersection over union (mIoU), four network architectures were tested: MobileUnet, AdapNet, DenseNet, and SegNet. The robustness of the trained network was additionally tested on a set of 47 image pairs of patients before and after orthodontic treatment. Results: SegNet was the most accurate network, producing 95.19% accuracy and an average mIoU value of 86.66% for the main sample and 86.2% for pre- and post-treatment images. Conclusions: Four architectural tests were developed for automated individual teeth segmentation and detection in two-dimensional photos that required no post-processing. Accuracy and robustness were best achieved with SegNet. Further research should focus on clinical applications and 3D system development.

2 June 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
Abdul Rehman El BsatAbdul Rehman El Bsat
Abdul Rehman El Bsat
ESElie Shammas
Elie Shammas
DADaniel Asmar
Daniel Asmar
KZKinan G. Zeno
Kinan G. Zeno
AMAnthony Macari
Anthony Macari
JGJoseph G Ghafari
Joseph G Ghafari
Background: The segmentation of individual teeth in three-dimensional (3D) dental models is a key step in orthodontic computer-aided design systems. Traditional methods lack robustness when handling challenging cases such as missing or misaligned teeth. Objectives: to semantically segment maxillary teeth and palatal rugae in 3D textured scans using Convolutional Neural Networks (CNNs) and assess tooth movement after orthodontic treatment using stable rugae references. Methods: Building on the robustness of two-dimensional image semantic segmentation, we developed a method to convert 3D textured palate scans into two-dimensional images for segmentation, then back projected them onto the original 3D meshes. A dataset of 100 textured scans from 100 patients seeking orthodontic treatment was manually segmented by orthodontic experts. The proposed 3D segmentation method was applied to these scans. Finally, each pair of segmented 3D scans from the same patient, before and after treatment, was aligned by superimposing them on the stable rugae region. Results: The 3D segmentation method achieved an accuracy of 98.69% and an average Intersection over Union (IoU) of 84.5%. The common stable coordinate frame for both scans using the rugae area as a stable reference enabled the computation of the 3D translational and rotational motions of each maxillary tooth. Neither pre- nor post-processing of the data was required to enhance segmentation. Conclusions: The proposed method enabled successful motion measurement of teeth using the rugal area as a stable reference and providing rotation and translational measurements of the maxillary teeth.