Adam Brian Nulty

Prof. Adam Brian Nulty

University of Leeds
+2
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2021 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
ANAdam Brian Nulty
Adam Brian Nulty
(1) Background: The purpose of this study is to evaluate the full arch scan accuracy (precision and trueness) of nine digital intra-oral scanners and four lab scanners. Previous studies have compared the accuracy of some intra-oral scanners, but as this is a field of quickly developing technologies, a more up-to-date study was needed to assess the capabilities of currently available models. (2) Methods: The present in vitro study compared nine different intra-oral scanners (Omnicam 4.6; Omnicam 5.1; Primescan; CS 3600; Trios 3; Trios 4; Runyes; i500; and DL206) as well as four lab light scanners (Einscan SE; 300e; E2; and Ineos X5) to investigate the accuracy of each scanner by examining the overall trueness and precision. Ten aligned and cut scans from each of the intra-oral and lab scanners in the in vitro study were brought into CloudCompare. A comparison was made with the master STL using the CloudCompare 3D analysis best-fit algorithm. The results were recorded along with individual standard deviation and a colorimetric map of the deviation across the surface of the STL mesh; a comparison was made to the master STL, quantified at specific points. (3) Results: In the present study, the Primescan had the best overall trueness (17.3 ± 4.9), followed by (in order of increasing deviation) the Trios 4 (20.8 ± 6.2), i500 (25.2 ± 7.3), CS3600 (26.9 ± 15.9), Trios 3 (27.7 ± 6.8), Runyes (47.2 ± 5.4), Omnicam 5.1 (55.1 ± 9.5), Omnicam 4.6 (57.5 ± 3.2), and Launca DL206 (58.5 ± 22.0). Regarding the lab light scanners, the Ineos X5 had the best overall trueness with (0.0 ± 1.9), followed by (in order of increasing deviation) the 3Shape E2 (3.6 ± 2.2), Up3D 300E (12.8 ± 2.7), and Einscan SE (14.9 ± 9.5). (4) Conclusions: This study confirms that all current generations of intra-oral digital scanners can capture a reliable, reproducible full arch scan in dentate patients. Out of the intra-oral scanners tested, no scanner produced results significantly similar in trueness to the Ineos X5. However, the Primescan was the only one to be statistically of a similar level of trueness to the 3Shape E2 lab scanner. All scanners in the study had mean trueness of under 60-micron deviation. While this study can compare the scanning accuracy of this sample in a dentate arch, the scanning of a fully edentulous arch is more challenging. The accuracy of these scanners in edentulous cases should be examined in further studies.

26 May 2022 in BDJ Open
Verified
Journal Article
Open access
PDF file
ANAdam Brian Nulty
Adam Brian Nulty
Introduction: Judging the dimensional accuracy of the resulting printed part requires comparison and conformity between the 3D printed model and its virtual counterpart. The resolution and accuracy of 3D model samples are determined by a wide array of factors depending on the technology used and related factors such as the print head/laser spot size/screen resolution, build orientation, materials, geometric features, and their topology. Aims: The aim of this manuscript is to present a literature review on 12 3D printers, namely the Ackuretta Sol, Anycubic Photon and Photon S, Asiga Max UV, Elegoo Mars, Envisiontec Vida HD, Envisiontec One, Envisiontec D4K Pro, Formlabs Form 2 and Form 3, Nextdent 5100, and Planmeca Creo, studying the accuracy of these printers that are of a wide variety of budgets. Design: The present study involves some of the recently released 3D printers that have not yet been studied for their accuracy. Since these new printers will replace current models that may have been included in the previous studies in the literature, it is important to study whether they are statistically more or less accurate and to discuss whether these results are clinically relevant. For the purposes of this study, the use of a standardised printable object was used to measure the accuracy of these recent 3D printers. Materials and methods: In total, 12 3D printers produced test blocks. All test blocks were printed using the same settings with 100 micron Z layer thickness and the print time set to standard where applicable. To measure the resulting blocks a digital measurement was taken using a Dentsply Sirona Ineos X5 lab scanner to measure the XYZ dimensions of each block produced on each printer using CloudCompare to measure the deviation compared to the Master STL. Each measurement was taken from the central axis of that dimension. Results: When grouped into homogenous subsets, the cheapest 3D printers in the group, namely the Anycubic printers and the Elegoo Mars, are statistically not dissimilar to the higher priced Asiga Max UV or even the mid-priced Formlabs printers in the X and Z dimensions. However, the Envisiontec One and D4K Pro, Ackuretta Sol and Asiga Max UV were statistically superior in terms of consistently accurate Y dimension. Although these printers use different technologies to print, no specific type of printer technology is more accurate than the others. Discussion: The null hypothesis was proved to be true, in that no significant differences were found among the various technologies of 3D printing regarding trueness and precision. The evolution of 3D printers that leads to budget printers being as statistically accurate, for at least two of the dimensions of data recorded, as expensive printers is remarkable. Whilst clear differences in the mean error between the printers were found, the performance of these printers is considered exceptional. Albeit, the Envision One, Envision D4K, Ackuretta Sol and Asiga Max UV printers performed the best with overall trueness under 35 μm. Conclusion: This study shows that the current range of 3D printers can produce clinically acceptable levels of accuracy. The present study also shows that there is no statistical difference in the results of budget printers and more expensive printers for the X and Z dimensions but this was not the case for the measurements in the Y dimension. This study confirms that all of the 3D printers can produce a reliable, reproducible model.

9 February 2024 in British Dental Journal
Verified
Journal Article
Open access
PDF file
ANAdam Brian Nulty
Adam Brian Nulty
This is an extensive review of the literature on prosthetically designed implant planning with particular regard to the factors influencing dental implant success. Electronic searches on PubMed and the Cochrane Central Register of Controlled Trials and manual searches were performed. The author selected the studies according to the inclusion and exclusion criteria. Meta-analysis of implant placement accuracy and a qualitative review of potential influencing factors were performed.This literature review will explore prosthetically designed implant placement and its influence on dental implant success. By examining the factors that impact implant outcomes, this review aims to provide clinicians with a comprehensive understanding of the key considerations and best practices in achieving successful implant placements. Ultimately, this knowledge can contribute to enhancing patient care and the long-term success of dental implant treatments.

20 November 2020 in British Dental Journal
Verified
Journal Article
Open access
PDF file
ANAdam Brian Nulty
Adam Brian Nulty
CLChris Lefkaditis
Chris Lefkaditis
PZPatrik Zachrisson
Patrik Zachrisson
QTQuintus Van Tonder
Quintus Van Tonder
RYRiaz Yar
Riaz Yar
Introduction External high-volume extraction (HVE) devices may offer a way to reduce any aerosol particulate generated. Aims The aim of this study was to measure the particle count during dental aerosol generating procedures and compare the results with when a HVE device is used. Design A comparative clinical study measuring the amount of PM1, PM2.5 and PM10 aerosol particulate with and without the use of an external HVE device was undertaken. Materials and methods In total, ten restorative procedures were monitored with an industrial Trotec PC220 particle counter. The intervention was an external HVE device. Main outcome methods The air sampler was placed at the average working distance of the clinicians involved in the study - 420 mm. Results In the present study, aerosol particulate was recorded at statistically significantly increased levels during dental procedures without an external HVE deviceversus with the device. Discussion The null hypothesis was rejected, in that significant differences were found between the results of the amount of aerosol particle count with and without a HVE device. Conclusion If the results of the present study are repeated in an in vivo setting, an external high-volume suction device may potentially show a lower risk of transmission of viral particulate.

18 November 2024 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
ANAdam Brian Nulty
Adam Brian Nulty
Background: This retrospective in vivo study evaluated the trueness and precision of two digital intraoral scanners—Dentsply Sirona Primescan and Medit i900—, both with and without two variants of the novel Scan Ladder aids, and compared their performance to a new intraoral photogrammetry scanner (Shining 3D Elite). Methods: Data from ten edentulous patients, previously collected during routine clinical treatment, were analyzed using a master STL generated from traditional impression casts as the reference. A custom positional change calculator and comprehensive statistical analysis were used to assess scanner accuracy. Results: The findings demonstrated that the use of the Scan Ladder significantly enhanced the overall accuracy of both intraoral scanners, showing no statistically significant differences when compared to the intraoral photogrammetry system. Conclusions: These results indicate that the Scan Ladder improves the performance of conventional intraoral scanners and suggests that the Shining 3D Elite intraoral photogrammetry scanner is a reliable alternative to extraoral photogrammetry for edentulous cases. Further research, with a larger and more diverse cohort, is warranted to validate and expand upon these findings.

13 November 2025 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
ANAdam Brian Nulty
Adam Brian Nulty
CKCameron Thomas Kelly
Cameron Thomas Kelly
OAOliver Ambridge
Oliver Ambridge
MAMark Ambridge
Mark Ambridge
RFRick Ferguson
Rick Ferguson
AHAshtyn Hoffer
Ashtyn Hoffer
Background: Accurate digital transfer of implant positions is critical for the long-term success of full-arch prosthetic rehabilitation. Photogrammetry remains the benchmark for accuracy, but its high cost and complexity limit clinical adoption. Artificial intelligence (AI)-driven intraoral scanning protocols incorporating real-time library matching and irregular, individually coded scan bodies have been proposed as accessible alternatives to improve accuracy and reproducibility. Methods: This in vitro study evaluated the trueness and precision of a full-arch implant scanning workflow using an AI-assisted real-time library matching system in combination with irregular multi-geometry titanium scan bodies. A high-accuracy structured-light scanner served as the reference standard. Six implant positions (35, 33, 31, 41, 43, 45) were scanned across 20 datasets (n = 120). Mean surface deviations were calculated against the reference STL using CloudCompare v.2.14. and a two-way ANOVA (α = 0.05) in SPSS tested the effects of implant position and scan iteration. Results: The workflow achieved a mean deviation of 13.55 ± 9.70 μm (range 0.77–43.46 μm) across all positions. Anterior sites showed the lowest deviations (e.g., position 31: 3.95 μm; 45: 5.96 μm), while posterior sites exhibited higher deviations (e.g., position 43: 26.15 μm). No mean deviation exceeded 30 μm, and no individual measurement surpassed 45 μm. Implant position significantly affected accuracy (p < 0.001), whereas scan iteration did not (p > 0.05). Conclusions: Within the limitations of this in vitro model, an AI-assisted real-time library matching workflow used in conjunction with irregular multi-geometry scan bodies achieved accuracy levels well within clinically acceptable ranges for full-arch implant impressions. Although comparable to values reported for photogrammetry under laboratory conditions, clinical equivalence should not be assumed. Further in vivo validation is required to confirm performance under routine clinical conditions.