Adityakrisna Yoshi Putra Wigianto

Dr. Adityakrisna Yoshi Putra Wigianto

Tokushima University, Tokushima, Japan
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2021 in International Journal of Implant Dentistry
Verified
Journal Article
Open access
PDF file
Adityakrisna Yoshi Putra WigiantoAdityakrisna Yoshi Putra Wigianto
Adityakrisna Yoshi Putra Wigianto
TGTakaharu Goto
Takaharu Goto
YIYuki Iwawaki
Yuki Iwawaki
YIYuichi Ishida
Yuichi Ishida
MWMegumi Watanabe
Megumi Watanabe
TITetsuo Ichikawa
Tetsuo Ichikawa
Background: Implant-assisted removable partial dentures (IARPDs) have recently become popular, but little information is available on the treatment outcomes based on the Kennedy classification and attachment types. Objective: The objective of this review was to evaluate the treatment outcomes of IARPD delivered for distal extension edentulous areas based on the differences in the Kennedy classification and attachment type. Materials and methods: English-language clinical studies on IARPD published between January 1980 and February 2020 were collected from MEDLINE (via PubMed), the Cochrane Library (via the Cochrane Central Register of Controlled Trials), Scopus online database, and manual searching. Two reviewers selected the articles based on pre-determined inclusion and exclusion criteria, followed by data extraction and analysis. Results: Eighty-one studies were selected after evaluating the titles and abstracts of 2410 papers. Nineteen studies were finally included after the perusal of the full text. Fourteen studies focused on Class I, 4 studies investigated both Class I and II, and only 1 study was conducted on Kennedy’s class II. Eight types of attachments were reported. The ball attachment was the most frequently used attachment, which was employed in 8 of the included studies. The implant survival rate ranged from 91 to 100%. The reported marginal bone loss ranged from 0.3 mm to 2.30 mm. The patient satisfaction was higher with IARPD than with conventional RPDs or that before treatment. The results of prosthetic complications were heterogeneous and inconclusive. Conclusion: IARPD exhibited favorable clinical outcomes when used as a replacement for distal extension edentulous areas. The comparison between the clinical outcomes of Kennedy’s class I and II was inconclusive owing to the lack of studies focusing on Kennedy Class II alone. The stud attachment was the most commonly used type in IARPDs. Overall, the different attachment systems did not influence the implant survival rate and patient satisfaction. Further high-quality studies are needed to investigate the attachment systems used in IARPD.

2 May 2022 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Adityakrisna Yoshi Putra WigiantoAdityakrisna Yoshi Putra Wigianto
Adityakrisna Yoshi Putra Wigianto
YIYuichi Ishida
Yuichi Ishida
TMTakashi Matsuda
Takashi Matsuda
TGTakaharu Goto
Takaharu Goto
MWMegumi Watanabe
Megumi Watanabe
TITetsuo Ichikawa
Tetsuo Ichikawa
Recently, a novel magnetic attachment with extremely low cost and high performance was developed. This article aims to introduce a novel magnetic attachment and to evaluate its basic eligibility for denture retention in clinical practice. The novel magnetic attachment system used in this study was the direct-bonding root-keeper-type Magteeth™ MT800 (MagneDesign, Nagoya, Japan). The retentive force without displacement (position 0) and after horizontal displacement to positions 0.5, 1, 1.5, 2, 2.5, and 3 mm were measured. The values relative to the retentive force without displacement were gradually decreased to 82.7 ± 16.3%, 68.8 ± 17.1%, 62.4 ± 15%, 47.2 ± 13.1%, 35.7 ± 9.9%, and 20.7 ± 6.5%, respectively. The retentive force and magnetic field strength did not change significantly after the load test (100 N load, 10,000 times). No new gap between the metal and resin was found in the root keeper- and magnet assembly-embedded blocks after the load test. Some scratches on magnetic assembly and root keeper surface, while no change in the resin texture after the load test were observed. Based on the findings of this preliminary study, this novel low-cost magnetic attachment exhibited favorable retention, strength, and durability for clinical use.

1 January 2025 in Journal of Oral Science
Verified
Journal Article
Open access
PDF file
YOYuuri Oku
Yuuri Oku
HSHideki Suito
Hideki Suito
KFKeiko Fujimoto
Keiko Fujimoto
Adityakrisna Yoshi Putra WigiantoAdityakrisna Yoshi Putra Wigianto
Adityakrisna Yoshi Putra Wigianto
TITetsuo Ichikawa
Tetsuo Ichikawa
KNKan Nagao
Kan Nagao
Purpose: The purpose of this study was to investigate swallowing function of older adults with lowered hyoid bone position.Methods: A total of 60 older adults (23 males and 37 females, mean age: 70.1 years) with no diagnosed dysphagia participated in the study. Participants were divided into two groups (High and Low group) based on the anterior point of the hyoid bone (H) with respect to the line connecting the most inferior and anterior point on the corpus of the third cervical vertebra (C3) and Menton (Me). Swallowing function was measured using the Repetitive Saliva Swallow Test (RSST), the Eating Assessment Tool (EAT-10), jaw-opening force (JOF) and tongue pressure (TP). Each group was studied for its relationship to swallowing function. Additionally, the RSST of males and females in the Low group were compared.Results: Males in the Low group had a significantly higher JOF (P = 0.009) in the RSST ≥ 5 group than in the RSST < 5 group. Females in the Low group had no measurements that showed significant differences between the RSST ≥ 4 and RSST < 4 groups.Conclusion: JOF may affect swallowing function in older males with lowered hyoid bone position.

18 February 2024 in Hygiene
Verified
Journal Article
Open access
PDF file
Adityakrisna Yoshi Putra WigiantoAdityakrisna Yoshi Putra Wigianto
Adityakrisna Yoshi Putra Wigianto
MWMegumi Watanabe
Megumi Watanabe
YIYuki Iwawaki
Yuki Iwawaki
TGTakaharu Goto
Takaharu Goto
TOTamaki Otsuki
Tamaki Otsuki
TITetsuo Ichikawa
Tetsuo Ichikawa
This in vitro study aimed to confirm the effect of the additional features of Kirei Keep Light (KKL), a commercial UV-C irradiation system that was originally created for coating the surface of removable dentures with photoreactive 2-methacryloyloxyethyl phosphorylcholine (MPC), on the antimicrobial efficacy aspect against Candida albicans biofilm on a denture base material (PMMA) and SARS-CoV-2. Materials and Methods: The antimicrobial efficacy on C. albicans biofilm was evaluated through quantitative (CFU) and qualitative (SEM images) analysis of three groups: no treatment (control), KKL, and immersion in a disinfectant solution, MCAE. The quantitative evaluation on SARS-CoV-2 was performed by comparing the untreated (control) group and the KKL group. Results: In comparison with the control group (2.39 × 106 CFU/mL), KKL irradiation resulted in a 91.01% reduction in C. albicans biofilm (2.15 × 105 CFU/mL), whereas for the MCAE group, this reduction was 99.98% (4.64 × 102 CFU/mL). The SEM image results also corroborate the CFU results, which showed that the fewest clean surfaces were found in the control, and this gradually increased with KKL and MCAE. SARS-CoV-2 inhibition, indicated by its TCID50 value, demonstrated that KKL almost completely inhibited SARS-CoV-2 infection and replication (99.99% reduction). Conclusion: KKL possesses antimicrobial efficacy on C. albicans biofilm on PMMA and SARS-CoV-2.

31 December 2025 in Journal of Dentistry
Verified
Journal Article
Open access
DMDiana Fitri Muslimah
Diana Fitri Muslimah
Adityakrisna Yoshi Putra WigiantoAdityakrisna Yoshi Putra Wigianto
Adityakrisna Yoshi Putra Wigianto
KSKittisak Sanon
Kittisak Sanon
KKKohei Kamoi
Kohei Kamoi
YIYumika Ida
Yumika Ida
KHKeiichi Hosaka
Keiichi Hosaka
This study evaluated the dimensional accuracy (trueness and precision) of direct composite veneer restorations fabricated using a composite injection technique by investigating the effects of clear index designs, composite flowabilities, and impression modality used for master model fabrication. An in vitro 3 × 3 × 2 factorial design (N = 90; n = 5 per group) was used to assess three index configurations (monolayer-closed, MC; monolayer-open, MO; and bilayer-open, BO), three composite flowabilities (super-low, low, and high), and two impression modalities (conventional and digital). All specimens were digitized and superimposed onto a reference model to quantify trueness and precision using a root-mean square analysis. Data was analyzed using a generalized linear model (α = 0.05). Trueness was significantly affected by index design and impression technique (p < 0.05), and the BO index and digital impressions achieved the highest dimensional accuracy. The digital-BO combination yielded a 48.1 % improvement over the least accurate workflow. Precision was significantly affected by all three factors (p < 0.05). Conversely, conventional impression demonstrated superior overall precision (p < 0.001) driven by a significant three-way interaction (p < 0.001) in which the digital- and conventional-MO-high groups showed poorest repeatability (111.1 µm) and highest precision (38.8 µm), respectively. Index design and impression techniques are primary factors affecting dimensional accuracy. The rigid BO index consistently enhances both trueness and precision; digital impressions optimize trueness, and conventional impressions show superior precision. Clinicians should prioritize rigid bilayer indices to achieve predictable veneer accuracy.