Andrew D. Nordin

Dr. Andrew D. Nordin

Biomedical Engineering, University of Houston, Houston, Texas, USA
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Andrew D. NordinAndrew D. Nordin
Andrew D. Nordin
WHW. David Hairston
W. David Hairston
DFDaniel P. Ferris
Daniel P. Ferris
To better understand human brain dynamics during visually guided locomotion, we developed a method of removing motion artifacts from mobile electroencephalography (EEG) and studied human subjects walking and running over obstacles on a treadmill. We constructed a novel dual-layer EEG electrode system to isolate electrocortical signals, and then validated the system using an electrical head phantom and robotic motion platform. We collected data from young healthy subjects walking and running on a treadmill while they encountered unexpected obstacles to step over. Supplementary motor area and premotor cortex had spectral power increases within ~200 ms after object appearance in delta, theta, and alpha frequency bands (3–13 Hz). That activity was followed by similar posterior parietal cortex spectral power increase that decreased in lag time with increasing locomotion speed. The sequence of activation suggests that supplementary motor area and premotor cortex interrupted the gait cycle, while posterior parietal cortex tracked obstacle location for planning foot placement nearly two steps ahead of reaching the obstacle. Together, these results highlight advantages of adopting dual-layer mobile EEG, which should greatly facilitate the study of human brain dynamics in physically active real-world settings and tasks.

13 June 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
Andrew D. NordinAndrew D. Nordin
Andrew D. Nordin
WHW. David Hairston
W. David Hairston
DFDaniel Ferris
Daniel Ferris
Objective: Our aim was to determine if walking speed affected human sensorimotor electrocortical dynamics using mobile high-density electroencephalography (EEG). Methods: To overcome limitations associated with motion and muscle artifact contamination in EEG recordings, we compared solutions for artifact removal using novel dual-layer EEG electrodes and alternative signal processing methods. Dual-layer EEG simultaneously recorded human electrocortical signals and isolated motion artifacts using pairs of mechanically coupled and electrically independent electrodes. For electrical muscle activity removal, we incorporated electromyographic (EMG) recordings from the neck into our mobile EEG data processing pipeline. We compared artifact removal methods during treadmill walking at four speeds (0.5, 1.0, 1.5, and 2.0 m/s). Results: Left and right sensorimotor alpha and beta spectral power increased in contralateral limb single support and push off, and decreased during contralateral limb swing at each speed. At faster walking speeds, sensorimotor spectral power fluctuations were less pronounced across the gait cycle with reduced alpha and beta power (p <; 0.05) compared to slower speeds. Isolated noise recordings and neck EMG spectral power fluctuations matched gait events and showed broadband spectral power increases at faster speeds. Conclusion and significance: Dual-layer EEG enabled us to isolate changes in human sensorimotor electrocortical dynamics across walking speeds. A comparison of signal processing approaches revealed similar intrastride cortical fluctuations when applying common (e.g., artifact subspace reconstruction) and novel artifact rejection methods. Dual-layer EEG, however, allowed us to document and rule out residual artifacts, which exposed sensorimotor spectral power changes across gait speeds.

3 April 2018 in Sensors
Verified
Journal Article
Open access
PDF file
ESEvangelia-Regkina Symeonidou
Evangelia-Regkina Symeonidou
Andrew D. NordinAndrew D. Nordin
Andrew D. Nordin
WHW. David Hairston
W. David Hairston
DFDaniel Ferris
Daniel Ferris
More neuroscience researchers are using scalp electroencephalography (EEG) to measure electrocortical dynamics during human locomotion and other types of movement. Motion artifacts corrupt the EEG and mask underlying neural signals of interest. The cause of motion artifacts in EEG is often attributed to electrode motion relative to the skin, but few studies have examined EEG signals under head motion. In the current study, we tested how motion artifacts are affected by the overall mass and surface area of commercially available electrodes, as well as how cable sway contributes to motion artifacts. To provide a ground-truth signal, we used a gelatin head phantom with embedded antennas broadcasting electrical signals, and recorded EEG with a commercially available electrode system. A robotic platform moved the phantom head through sinusoidal displacements at different frequencies (0–2 Hz). Results showed that a larger electrode surface area can have a small but significant effect on improving EEG signal quality during motion and that cable sway is a major contributor to motion artifacts. These results have implications in the development of future hardware for mobile brain imaging with EEG.

23 August 2018 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
Andrew D. NordinAndrew D. Nordin
Andrew D. Nordin
WHW David Hairston
W David Hairston
DFDaniel Ferris
Daniel Ferris
Objective . Our purpose was to evaluate the ability of a dual electrode approach to remove motion artifact from electroencephalography (EEG) measurements. Approach . We used a phantom human head model and robotic motion platform to induce motion while collecting scalp EEG. We assembled a dual electrode array capturing (a) artificial neural signals plus noise from scalp EEG electrodes, and (b) electrically isolated motion artifact noise. We recorded artificial neural signals broadcast from antennae in the phantom head during continuous vertical sinusoidal movements (stationary, 1.00, 1.25, 1.50, 1.75, 2.00 Hz movement frequencies). We evaluated signal quality using signal-to-noise ratio (SNR), cross-correlation, and root mean square error (RMSE) between the ground truth broadcast signals and the recovered EEG signals. Main results . Signal quality was restored following noise cancellation when compared to single electrode EEG measurements collected with no phantom head motion. Significance . We achieved substantial motion artifact attenuation using secondary electrodes for noise cancellation. These methods can be applied to studying electrocortical signals during human locomotion to improve real-world neuroimaging using EEG.

1 September 2015 in Quarterly Journal of Experimental Psychology
Verified
Journal Article
Open access
BMBrad McKay
Brad McKay
GWGabriele Wulf
Gabriele Wulf
RLRebecca Lewthwaite
Rebecca Lewthwaite
Andrew D. NordinAndrew D. Nordin
Andrew D. Nordin
The self-invoking trigger hypothesis was proposed by Wulf and Lewthwaite [Wulf, G., & Lewthwaite, R. (2010). Effortless motor learning? An external focus of attention enhances movement effectiveness and efficiency. In B. Bruya (Ed.), Effortless attention: A new perspective in attention and action (pp. 75–101). Cambridge, MA: MIT Press] as a mechanism underlying the robust effect of attentional focus on motor learning and performance. One component of this hypothesis, relevant beyond the attentional focus effect, suggests that causing individuals to access their self-schema will negatively impact their learning and performance of a motor skill. The purpose of the present two studies was to provide an initial test of the performance and learning aspects of the self-invoking trigger hypothesis by asking participants in one group to think about themselves between trial blocks—presumably activating their self-schema—to compare their performance and learning to that of a control group. In Experiment 1, participants performed 2 blocks of 10 trials on a throwing task. In one condition, participants were asked between blocks to think about their past throwing experience. While a control group maintained their performance across blocks, the self group's performance was degraded on the second block. In Experiment 2, participants were asked to practice a wiffleball hitting task on two separate days. Participants returned on a third day to perform retention and transfer tests without the self-activating manipulation. Results indicated that the self group learned the hitting task less effectively than the control group. The findings reported here provide initial support for the self-invoking trigger hypothesis.

9 June 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
NRNatalie Richer
Natalie Richer
RDRyan J. Downey
Ryan J. Downey
WHW. David Hairston
W. David Hairston
DFDaniel Ferris
Daniel Ferris
Andrew D. NordinAndrew D. Nordin
Andrew D. Nordin
Motion and muscle artifacts can undermine signal quality in electroencephalography (EEG) recordings during locomotion. We evaluated approaches for recovering ground-truth artificial brain signals from noisy EEG recordings. We built an electrical head phantom that broadcast four brain and four muscle sources. Head movements were generated by a robotic motion platform. We recorded 128-channel dual layer EEG and 8-channel neck electromyography (EMG) from the head phantom during motion. We evaluated ground-truth electrocortical source signal recovery from artifact contaminated data using Independent Component Analysis (ICA) to determine: (1) the number of isolated noise sensor recordings needed to capture and remove motion artifacts, (2) the ability of Artifact Subspace Reconstruction to remove motion and muscle artifacts at contrasting artifact detection thresholds, (3) the number of neck EMG sensor recordings needed to capture and remove muscle artifacts, and (4) the ability of Canonical Correlation Analysis to remove muscle artifacts. We also evaluated source signal recovery by combining the best practices identified in aims 1-4. By including isolated noise and EMG recordings in the ICA decomposition, we more effectively recovered ground-truth artificial brain signals. A reduced subset of 32-noise and 6-EMG channels showed equivalent performance compared to including the complete arrays. Artifact Subspace Reconstruction improved source separation, but this was contingent on muscle activity amplitude. Canonical Correlation Analysis also improved source separation. Merging noise and EMG recordings into the ICA decomposition, with Artifact Subspace Reconstruction and Canonical Correlation Analysis preprocessing, improved source signal recovery. This study expands on previous head phantom experiments by including neck muscle source activity and evaluating artificial electrocortical spectral power fluctuations synchronized with gait events.