Ahmed M. Zobaa

Dr. Ahmed M. Zobaa

Electrical Power Engineering Department, Cairo University, Giza, Al Jīzah, Egypt
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2021
Verified
Conference Paper
Closed access
Ahmed M. ZobaaAhmed M. Zobaa
Ahmed M. Zobaa
Shady Abdel AleemShady Abdel Aleem
Shady Abdel Aleem
HYHosam K.M. Youssef
Hosam K.M. Youssef
The increasing use of nonlinear loads in power systems generates harmonics, which adversely affects these systems' power quality performance. In this regard, double-tuned filters (DTFs) have received increasing attention in practice to mitigate the effects of power system harmonics. Different techniques have been presented in the literature to obtain the optimal design of DTF parameters using various optimization algorithms. In this work, three methods for designing DTFs- multi-arm method (MAM), direct design method (DDM), and analogy method (AM) between double-tuned and multi-arm single-tuned filters, are investigated and discussed. Further, an optimal design of DTF based on the three design methodologies is presented. A new metaheuristic optimization algorithm called the slime mould optimization algorithm (SMA) is employed to obtain the global filter parameters to minimize the active power losses of a distribution system with both source and load nonlinearities while enhancing the overall power quality performance of the system. The results obtained using the SMA are compared with the results obtained using other algorithms: salp swarm algorithm (SSA) and sine cosine algorithm (SCA) to show the proposed optimization algorithm's superiority and effectiveness.

8 December 2022 in Ain Shams Engineering Journal
Verified
Journal Article
Open access
NKNor Hidayah Abdul Kahar
Nor Hidayah Abdul Kahar
RTRania A. Turky
Rania A. Turky
Ahmed M. ZobaaAhmed M. Zobaa
Ahmed M. Zobaa
SAShady H.E. Abdel Aleem
Shady H.E. Abdel Aleem
BIBazilah Ismail
Bazilah Ismail

15 December 2022 in Ain Shams Engineering Journal
Verified
Journal Article
Open access
Ahmed M. ZobaaAhmed M. Zobaa
Ahmed M. Zobaa
SAShady H.E. Abdel Aleem
Shady H.E. Abdel Aleem
HYHosam K.M. Youssef
Hosam K.M. Youssef

10 May 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MAMohammed M Alhaider
Mohammed M Alhaider
Shady Abdel AleemShady Abdel Aleem
Shady Abdel Aleem
Ziad AliZiad Ali
Ziad Ali
Ahmed M. ZobaaAhmed M. Zobaa
Ahmed M. Zobaa
This paper introduces a novel and improved double-resistor damped double-tuned passive power filter (DR-DDTF), designed using multi-objective optimization algorithms to mitigate harmonics and increase the hosting capacity of distribution systems with distributed energy resources. Although four different topologies of single-resistor damped double-tuned filters (DDTFs) have been studied before in the literature, the effectiveness of two different DR-DDTF configurations has not been examined. This work redresses this gap by demonstrating that via comprehensive simulations on two power systems, DR-DDTF provides better harmonic suppression and resonance mitigation than single-resistor alternatives. When it comes to optimizing the DR-DDTF for maximum hosting capacity and minimum system active power losses, the multi-objective artificial hummingbird outperformed six other algorithms in the benchmark. To allow for higher penetration of distributed generation without requiring grid upgrades, this newly developed harmonic mitigation filter provides a good alternative.

11 November 2024 in Fractal and Fractional
Verified
Journal Article
Open access
PDF file
AMAhmed Galal Eldien Mahmoud
Ahmed Galal Eldien Mahmoud
Mohamed El-BeltagyMohamed El-Beltagy
Mohamed El-Beltagy
Ahmed M. ZobaaAhmed M. Zobaa
Ahmed M. Zobaa
This work presents an improved modelling approach for wind turbine power curves (WTPCs) using fractional differential equations (FDE). Nine novel FDE-based models are presented for mathematically modelling commercial wind turbine modules’ power–velocity (P-V) characteristics. These models utilize Weibull and Gamma probability density functions to estimate the capacity factor (CF), where accuracy is measured using relative error (RE). Comparative analysis is performed for the WTPC mathematical models with a varying order of differentiation (α) from 0.5 to 1.5, utilizing the manufacturer data for 36 wind turbines with capacities ranging from 150 to 3400 kW. The shortcomings of conventional mathematical models in various meteorological scenarios can be overcome by applying the Riemann–Liouville fractional integral instead of the classical integer-order integrals. By altering the sequence of differentiation and comparing accuracy, the suggested model uses fractional derivatives to increase flexibility. By contrasting the model output with actual data obtained from the wind turbine datasheet and the historical data of a specific location, the models are validated. Their accuracy is assessed using the correlation coefficient (R) and the Mean Absolute Percentage Error (MAPE). The results demonstrate that the exponential model at α=0.9 gives the best accuracy of WTPCs, while the original linear model was the least accurate.

15 April 2026 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MBMohamed Sayed Badr
Mohamed Sayed Badr
HSH. M. Sharaf
H. M. Sharaf
Ahmed M. ZobaaAhmed M. Zobaa
Ahmed M. Zobaa
Car exhaust emissions significantly contribute to the depletion of the ozone layer. Electric vehicles (EVs) present a sustainable alternative to mitigate this environmental issue. However, the large-scale adoption of EVs introduces challenges for the power grid, primarily due to irregular and uncoordinated charging patterns. This study proposes a comprehensive two-stage framework for optimizing electric vehicle (EV) charging patterns and reactive power dispatch within power distribution systems. In Stage 1, two types of EV charging schedules are developed and compared: day-ahead charging and real-time charging. Day-ahead charging involves planning EV charging over a 24-hour horizon with the objective of minimizing load variance, energy cost, active power losses, and voltage drop, while simultaneously maximizing voltage stability. Real-time charging dynamically adjusts charging behavior based on immediate grid conditions to minimize load variance and charging costs. Stage 2 focuses on optimal real-time reactive power dispatch, utilizing the reactive power capabilities of EV inverters to further reduce the active and reactive power losses. Additionally, the study analyzes EV behavior in response to sudden load changes, providing critical insights for enhancing grid performance. Different optimization algorithms are implemented to efficiently solve the proposed models, including particle swarm optimization, dandelion optimization, wild horse optimization, and slime mould optimization. The optimization is formulated as a multi-objective problem to consider both grid constraints and customer satisfaction. The proposed framework is applied and tested on a 33-bus radial distribution system with 984 electric vehicles using MATLAB M-files, while power flow calculations are performed using the MATPOWER toolbox. Simulation results demonstrate the effectiveness of the proposed framework. Daily active power losses are reduced from 4.04 MWh to 2.55 MWh and 2.77 MWh under day-ahead and real-time planning strategies—representing reductions of 36.8% and 31.4%, respectively. Similarly, EV charging costs drop from 552.31 USD to 394.19 USD and 363.68 USD, achieving cost savings of 28.63% and 34.15%. Furthermore, voltage profiles are maintained within the acceptable operational limit of 0.95 p.u. These outcomes highlight the significant advantages of the proposed methodology in enhancing grid efficiency while ensuring user satisfaction.