27 September 2010 in Indoor Air
Verified
Journal Article
Closed access
PDF file
M.L. Alan FongM.L. Alan Fong
M.L. Alan Fong
John Zhang LinJohn Zhang Lin
John Zhang Lin
KFK.F. Fong
K.F. Fong
TCT. T. Chow
T. T. Chow
TYT. Yao
T. Yao
Thermal sensation is studied experimentally under mixing ventilation, displacement ventilation, and stratum ventilation in an environmental chamber. Forty‐eight subjects participated in all tests under the same boundary conditions but different ventilation methods in the classroom. Thermal comfort analysis was carried out according to the designated supply airflow rate, room temperature, and relative humidity for the three ventilation methods. The thermal neutral temperature under stratum ventilation is approximately 2.5°C higher than that under mixing ventilation and 2.0°C higher than that under displacement ventilation. This result indicates that stratum ventilation could provide satisfactory thermal comfort level to rooms of temperature up to 27°C. The energy saving attributable to less ventilation load alone is around 12% compared with mixing ventilation and 9% compared with displacement ventilation. Practical Implications The confirmation of the significantly elevated thermal neutral temperature can have a number of implications for both thermal comfort in an air‐conditioned room and energy consumption of the associate air‐conditioning system. With respect to the former, it provides scientific basis for the feasibility of elevated room temperatures, and with respect to the latter, it reveals considerable potentials for energy saving.

6 January 2022 in Energy Storage Materials
Verified
Journal Article
Closed access
DGDian-Ce Gao
Dian-Ce Gao
YSYongjun Sun
Yongjun Sun
M.L. Alan FongM.L. Alan Fong
M.L. Alan Fong
XGXiaobin Gu
Xiaobin Gu

1 April 2018 in Building and Environment
Verified
Journal Article
Closed access
ZFZhaosong Fang
Zhaosong Fang
Sheng ZhangSheng Zhang
Sheng Zhang
YCYong Cheng
Yong Cheng
M.L. Alan FongM.L. Alan Fong
M.L. Alan Fong
MOMajeed Olaide Oladokun
Majeed Olaide Oladokun
HWHuijun Wu
Huijun Wu

1 October 2015 in Building and Environment
Verified
Journal Article
Closed access
YCYong Cheng
Yong Cheng
John Zhang LinJohn Zhang Lin
John Zhang Lin
M.L. Alan FongM.L. Alan Fong
M.L. Alan Fong

19 January 2014 in Indoor Air
Verified
Journal Article
Closed access
PDF file
YCY. Cheng
Y. Cheng
M.L. Alan FongM.L. Alan Fong
M.L. Alan Fong
TYT. Yao
T. Yao
John Zhang LinJohn Zhang Lin
John Zhang Lin
KFK.F. Fong
K.F. Fong
Three human test series were conducted to evaluate the uniformity of the thermal environments in a stratum‐ventilated chamber with dimensions of 8.8 m (L) × 5.1 m (W) × 2.4 m (H). In all, nineteen conditions were generated by adjusting the room temperature, supply airflow rate, and supply terminal type. An air diffuser performance index (ADPI) of at least 80% was achieved for most cases. This result shows that the air velocity and temperature in the occupied zone are reasonably uniform. Subjective assessments using the ASHRAE 7‐point scale indicate that the thermal sensations of the subjects in stratum ventilation are also uniform. This study examines the applicability of the predicted mean vote (PMV) model for evaluating stratum ventilation. When compared to the actual mean thermal sensation votes (ATS), the PMV values are acceptable. The PMV results at a height of 1.1 m above the floor show better agreement with the ATS than at a height of 0.1 m.