Alberto Alonso Romero

Mr. Alberto Alonso Romero

École de Technologie Supérieure - ÉTS, Montreal West, Canada
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
ARAlberto Alonso Romero
Alberto Alonso Romero
Koffi Novignon AmouzouKoffi Novignon Amouzou
Koffi Novignon Amouzou
DSDipankar Sengupta
Dipankar Sengupta
CZCamila Aparecida Zimmermann
Camila Aparecida Zimmermann
ARAndréane Richard-Denis
Andréane Richard-Denis
BUBora Ung
Bora Ung
We report the design and testing of a sensor pad based on optical and flexible materials for the development of pressure monitoring devices. This project aims to create a flexible and low-cost pressure sensor based on a two-dimensional grid of plastic optical fibers embedded in a pad of flexible and stretchable polydimethylsiloxane (PDMS). The opposite ends of each fiber are connected to an LED and a photodiode, respectively, to excite and measure light intensity changes due to the local bending of the pressure points on the PDMS pad. Tests were performed in order to study the sensitivity and repeatability of the designed flexible pressure sensor.

9 August 2022 in Photonics
Verified
Journal Article
Open access
PDF file
Koffi Novignon AmouzouKoffi Novignon Amouzou
Koffi Novignon Amouzou
ARAlberto Alonso Romero
Alberto Alonso Romero
DSDipankar Sengupta
Dipankar Sengupta
Satyendra Kumar MishraSatyendra Kumar Mishra
Satyendra Kumar Mishra
ARAndréane Richard-Denis
Andréane Richard-Denis
BUBora Ung
Bora Ung
We present the fabrication and characterization of elastomeric optical waveguides, to be used for the manufacture of a conformable, water-resistant, and cost-effective pressure sensor that is amenable to the development of smart wearable health monitoring devices. To achieve this goal, high-sensitivity polydimethylsiloxane waveguides with a rectangular cross-section were fabricated. A new up-doping procedure, to tailor the refractive index of the ensuing waveguides, was experimentally developed using benzophenone additives. With this method we demonstrated a high refractive index change (up to +0.05) as a linear function of the benzophenone doping concentration. Propagation losses of about 0.37 dB/cm in the visible range and a high sensitivity to transverse compression of 0.10%/dB optical power loss were measured. It was also shown that one can further control the refractive index of the waveguide core and cladding regions through proper selection of the polydimethylsiloxane base to curing agent mixing ratio.

10 July 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Koffi Novignon AmouzouKoffi Novignon Amouzou
Koffi Novignon Amouzou
ARAlberto Alonso Romero
Alberto Alonso Romero
DSDipankar Sengupta
Dipankar Sengupta
CZCamila Aparecida Zimmermann
Camila Aparecida Zimmermann
AKAashutosh Kumar
Aashutosh Kumar
BUBora Ung
Bora Ung
We report a new concept of a pressure sensor fully made from polydimethylsiloxane with a solid core and porous cladding that operates through (frustrated) total internal reflection. A flexible and sensitive rectangular cross-section waveguide was fabricated via the casting and molding method. The waveguide’s optical losses can be temperature-controlled during the fabrication process by controlling the quantity of microbubbles incorporated (2% approximately for samples made at 70 °C). By controlling the precuring temperature, the microbubbles are incorporated into the waveguides during the simple and cost-effective fabrication process through the casting and molding method. For these samples, we measured good optical loss tradeoff of the order of 1.85 dB/cm, which means that it is possible to fabricate a solid-core/clad waveguide with porous cladding able to guide light properly. We demonstrated the microbubble concentration control in the waveguide, and we measured an average diameter of 239 ± 16 µm. A sensitivity to pressure of 0.1035 dB/kPa optical power loss was measured. The results show that in a biomedical dynamic pressure range (0 to 13.3 kPa), this new device indicates the critical pressure threshold level, which constitutes a crucial asset for potential applications such as pressure injury prevention.

20 February 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ARAlberto Alonso Romero
Alberto Alonso Romero
Koffi Novignon AmouzouKoffi Novignon Amouzou
Koffi Novignon Amouzou
DSDipankar Sengupta
Dipankar Sengupta
JLJean-Marc Lina
Jean-Marc Lina
BUBora Ung
Bora Ung
This work presents a signal processing and reconstruction system developed for a flexible optical pressure 2D mapping sensor. The sensor consists of a two-dimensional grid of polyurethane optical fibers (PU-OFs) embedded in polydimethylsiloxane (PDMS), which acts as the input device for acquiring light intensity changes caused by external surface-applied pressure. In this study, we propose a system to process these signals through an inverse model based on the Moore–Penrose pseudoinverse for spatial localization, along with a point-specific pressure estimation model to infer the magnitude of the applied force, which is then used to generate quantitative pressure maps. Experimental results show the system’s overall performance, robustness, and repeatability across multiple pressure levels and locations. In most cases, localization errors remain below 5 mm, while pressure estimation errors are around 5 mmHg when the pressure is correctly localized. Performance metrics, such as recall, specificity, and precision, support the system’s ability to detect, localize, and reconstruct pressure events with consistent reliability. These results establish the viability of the proposed methodology for potential integration into low-cost and flexible optical fiber-based 2D pressure monitoring systems for biomedical applications.