Alberto Borghetti

Prof. Alberto Borghetti

University of Bologna - Advanced Research Center on Electronics Systems "Ercole De Castro"
orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2008 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
Alberto BorghettiAlberto Borghetti
Alberto Borghetti
CDClaudia D'Ambrosio
Claudia D'Ambrosio
ALAndrea Lodi
Andrea Lodi
SMSilvano Martello
Silvano Martello
The paper deals with a unit commitment problem of a generation company whose aim is to find the optimal scheduling of a multiunit pump-storage hydro power station, for a short term period in which the electricity prices are forecasted. The problem has a mixed-integer nonlinear structure, which makes very hard to handle the corresponding mathematical models. However, modern mixed-integer linear programming (MILP) software tools have reached a high efficiency, both in terms of solution accuracy and computing time. Hence we introduce MILP models of increasing complexity, which allow to accurately represent most of the hydroelectric system characteristics, and turn out to be computationally solvable. In particular we present a model that takes into account the head effects on power production through an enhanced linearization technique, and turns out to be more general and efficient than those available in the literature. The practical behavior of the models is analyzed through computational experiments on real-world data.

22 April 2008 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
Alberto BorghettiAlberto Borghetti
Alberto Borghetti
MBMauro Bosetti
Mauro Bosetti
MSMauro Di Silvestro
Mauro Di Silvestro
CNCarlo Alberto Nucci
Carlo Alberto Nucci
MPMario Paolone
Mario Paolone
The paper presents a fault location procedure for distribution networks based on the wavelet analysis of the fault-generated traveling waves. In particular, the proposed procedure implements the continuous wavelet analysis applied to the voltage waveforms recorded during the fault in correspondence of a network bus. In order to improve the wavelet analysis, an algorithm is proposed to build specific mother wavelets inferred from the fault-originated transient waveforms. The performance of the proposed algorithm are analyzed for the case of the IEEE 34-bus test distribution network and compared with those achieved by using the more traditional Morlet mother wavelet.

12 August 2010 in IEEE Systems Journal
Verified
Journal Article
Closed access
Alberto BorghettiAlberto Borghetti
Alberto Borghetti
MBMauro Bosetti
Mauro Bosetti
Samuele GrilloSamuele Grillo
Samuele Grillo
SMStefano Massucco
Stefano Massucco
CNCarlo Alberto Nucci
Carlo Alberto Nucci
Federico SilvestroFederico Silvestro
Federico Silvestro
Among the innovative contributions to electric distribution systems, one of the most promising and qualified is the possibility to manage and control distributed generation. Therefore, the latest distribution management systems tend to incorporate optimization functions for the short-term scheduling of the various energy and control resources available in the network (e.g., embedded generators, reactive power compensators and transformers equipped with on-load tap changers). The short-term scheduling procedure adopted in the paper is composed by two stages: a day-ahead scheduler for the optimization of distributed resources production during the following day, an intra-day scheduler that every 15 min adjusts the scheduling in order to take into account the operation requirements and constraints of the distribution network. The intra-day scheduler solves a non-linear multi-objective optimization problem by iteratively applying a mixed-integer linear programming (MILP) algorithm. The linearization of the optimization function and the constraints is achieved by the use of sensitivity coefficients obtained from the results of a three-phase power flow calculation. The paper shows the application of the proposed approach to a medium-voltage 120 buses network with five wind plants, one photovoltaic field, ten dispatchable generators, and two transformers equipped with on-load tap changers.

29 April 2010 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Alberto BorghettiAlberto Borghetti
Alberto Borghetti
MBM. Bosetti
M. Bosetti
CNC. A. Nucci
C. A. Nucci
MPM. Paolone
M. Paolone
AAA. Abur
A. Abur
The paper presents a procedure for fault location in distribution networks, based on the use of the integrated time-frequency wavelet decompositions of the voltage transients associated with the fault-originated travelling waves. The proposed analysis of time-frequency wavelet decompositions has been found to improve the identification accuracy of the frequencies associated to the characteristic patterns of a fault location with respect to a sole frequency-domain wavelet analysis. Several laboratory fault tests, carried out by means of a reduced-scale model of a distribution feeder, are used to illustrate the characteristics and assess the performances of the proposed improved procedure. The paper also illustrates the application of the proposed procedure to a transient, originated by a permanent phase-to-phase fault, measured in a real distribution network in which a post-test analysis has identified the faulted branch.

26 December 2006 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Alberto BorghettiAlberto Borghetti
Alberto Borghetti
CNCarlo Alberto Nucci
Carlo Alberto Nucci
MPMario Paolone
Mario Paolone
This paper deals with the assessment of the lightning performance of distribution lines, namely the estimation of the annual number of lightning-induced flashovers versus the critical flashover voltage of the line insulators. The procedure proposed by the authors is compared with the one described in IEEE Std. 1410-2004 Guide for improving the lightning performance of electric power overhead distribution lines. The two methods differ: 1) for the models adopted to evaluate the induced voltages and 2) for the adopted statistical approach. The reasons for differences in the results predicted by the two methods are discussed and the parameters playing the major role in the achievement of the results are identified. The proposed method represents an improvement compared to IEEE Std. 1410 because it takes into account more realistic line configurations and the effect of the finite ground conductivity

2 October 2019 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
Stefano LillaStefano Lilla
Stefano Lilla
COCamilo Orozco
Camilo Orozco
Alberto BorghettiAlberto Borghetti
Alberto Borghetti
FNFabio Napolitano
Fabio Napolitano
FTFabio Tossani
Fabio Tossani
The paper focuses on the day-ahead operational planning of a grid-connected local energy community (LEC) consisting of an internal low-voltage network and several prosumers including generation units, battery storage systems, and local loads. In order to preserve, as much as possible, the confidentiality of the features of prosumers' equipment and the production and load forecasts, the problem is addressed by designing a specific distributed procedure based on the alternating direction method of multipliers (ADMM). The distributed procedure calculates the scheduling of the available energy resources to limit the balancing action of the external grid and allocates the internal network losses to the various power transactions. Results obtained for various case studies are compared with those obtained by a centralized optimization approach. The results confirm that, in the considered LEC framework, each of the prosumers achieves a reduction in costs or increases revenues in case it participates to the LEC with respect to the case in which it can only transact with an external energy provider.