Alexandru Florin Diconi

Dr. Alexandru Florin Diconi

Lucian Blaga University of Sibiu, Sibiu, Romania
orcid
Asst. Prof.

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Alexandru Florin DiconiAlexandru Florin Diconi
Alexandru Florin Diconi
Mihai Dan RomanMihai Dan Roman
Mihai Dan Roman
ACAdrian Nicolae Cristian
Adrian Nicolae Cristian
ABAdrian Boicean
Adrian Boicean
CMCosmin Ioan Mohor
Cosmin Ioan Mohor
SFSorin Radu Fleaca
Sorin Radu Fleaca
Background/Objectives: Total knee arthroplasty (TKA) is the gold-standard treatment for advanced knee arthritis, offering pain relief and improved joint function. However, tibial component malalignment, malrotation, and improper biomechanical loading remain critical factors contributing to implant failure, instability, and revision surgeries. This review systematically examines the impact of biomechanical loading on the tibial insert following primary TKA, with a focus on alignment, posterior tibial slope (PTS), and load distribution. Methods: A systematic literature search was conducted across the PubMed, Google Scholar, and Web of Science databases following the PRISMA guidelines. Studies investigating the effects of tibial component alignment, varus/valgus deviations, PTS, and load distribution on tibial inserts post-TKA were included. Seven studies meeting the inclusion criteria were analyzed and described narratively. Results: The reviewed studies highlighted that varus and valgus malalignment significantly alter tibiofemoral contact pressures and ligament strains, increasing the risk of aseptic loosening and implant failure. Excessive PTS was associated with posterior femoral translation, altered ligament tension, and increased contact stresses on polyethylene (PE) inserts. Kinematically aligned TKA demonstrated reduced tibial force imbalances and improved functional outcomes compared to mechanically aligned TKA. Computational and cadaveric studies revealed that even minor malalignments (e.g., 3° varus or valgus) can cause significant biomechanical changes. Conclusions: Biomechanical loading on tibial inserts after primary TKA is highly sensitive to the alignment and PTS. Optimal alignment and controlled biomechanical forces are essential. Kinematically aligned TKA has shown promising effects, preventing aseptic loosening and ensuring long-term implant survival. Further in vivo studies are needed to validate these findings and optimize surgical techniques.

18 July 2025 in Journal of Experimental Orthopaedics
Verified
Journal Article
Open access
NINicolas Ion
Nicolas Ion
SFSorin Radu Fleaca
Sorin Radu Fleaca
BBBogdan‐Axente Bocea
Bogdan‐Axente Bocea
CMCosmin‐Ioan Mohor
Cosmin‐Ioan Mohor
MRMihai‐Dan Roman
Mihai‐Dan Roman
VBVictoria Birlutiu
Victoria Birlutiu
Purpose: The presence of pathogen microorganisms in the operating room remains a significant concern. This study aims to explore the factors influencing the presence of pathogens in the operating room. Methods: We analysed the presence of microorganisms in the operation theatre during total knee and hip replacement procedures for 33 patients performed in the same operation room (OR) over a period of 2 months. Three hundred and ninety‐six samples were taken from several areas belonging to the sterile field. We have also analysed behavioural aspects in the OR that could influenced the potential contamination of the sterile field, such as the number of touches of the lamps, the temperature in the OR, the height of the operating table, the number of door openings. Results: Out of the total of 396 samples, 74 were positive. Most contaminations were with Staphylococcus epidermidis (45.45%). Most pathogens were found on the instrument table at the end of the intervention (27.27%). There is a correlation regarding the fact that at lower heights, the risk of contamination higher than if the table is raised more. We also find correlations between the number of operating room doors opened and the presence of field contamination, as well as between the number of touches of the lamps and the presence of pathogens on sterile fields. Conclusion: The presence of pathogens in the OR is influenced by the number of lamp touches, the frequency of door openings, and the increased number of people in the room. However, temperature and the height of the operating table do not have a significant impact on the occurrence of pathogens. The most commonly found pathogen in the OR was S. epidermidis . At the end of the surgery, the instrument table showed the highest percentage of pathogen presence. Level of Evidence: Level IV, case series.

14 October 2024 in Cureus
Verified
Journal Article
Open access
BBBogdan A Bocea
Bogdan A Bocea
Mihai Dan RomanMihai Dan Roman
Mihai Dan Roman
RFRadu S Fleaca
Radu S Fleaca
NINicolas C Ion
Nicolas C Ion
RNRadu Necula
Radu Necula
RMRomeo G Mihaila
Romeo G Mihaila
The number of total hip and total knee replacements has increased steadily each year. Today, they are routinely performed all over the world. The increasing prevalence of obesity has led to an increase in the number of total knee arthroplasties (TKAs) performed in patients with a higher body mass index (BMI) and also has a higher rate of complications. Possible complications are infection, instability, misalignment, osteolysis, or fracture. Revision arthroplasty can be challenging due to bone defects, ligament instability, and difficulty in fixation. We present the case of a 66-year-old morbidly obese patient who underwent TKA. After the operation, infection and a mechanical complication of periprosthetic fracture of the tibial component occurred. The infection made the treatment more difficult. The patient had to undergo several surgeries in several stages to address the post-surgical complications. TKA in obese patients leads to a higher risk of postoperative complications.

14 April 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
NINicolas Ion
Nicolas Ion
SFSorin Radu Fleaca
Sorin Radu Fleaca
BBBogdan-Axente Bocea
Bogdan-Axente Bocea
CMCosmin Ioan Mohor
Cosmin Ioan Mohor
MRMihai-Dan Roman
Mihai-Dan Roman
Victoria BirlutiuVictoria Birlutiu
Victoria Birlutiu
Introduction: Periprosthetic joint infections (PJI) are among the most serious and costly complications in orthopedic surgery, significantly affecting patient prognosis and healthcare systems. Despite rigorous aseptic measures, intraoperative contamination of sterile fields, instruments, and air remains a persistent source of potential infection. This study investigates the relationship between the microbial contamination of sterile fields during arthroplasty and postoperative inflammatory markers, with the objective of determining whether the contamination of sterile fields correlates with the presence of periprosthetic joint infection (PJI). Material and Methods: This prospective observational study included 33 patients undergoing total hip or knee arthroplasty in a university-affiliated orthopedic center. Intraoperative samples were collected from sterile fields and equipment to detect microbial contamination, while postoperative monitoring involved the C-reactive protein (CRP); erythrocyte sedimentation rate (ESR); leukocyte count; temperature; and wound assessment on days 1, 3 and 7. All patients received 48 h of prophylactic cefuroxime. Statistical analysis was conducted using the International Business Machines (IBM) Statistical Product and Service Solutions (SPSS) software for Windows, version 30.0 (IBM Corporation, Armonk, New York, United States of America) with significance set at p ≤ 0.05. Results: Postoperative inflammatory markers showed distinct patterns depending on the isolated microorganism, with Proteus vulgaris and Staphylococcus hominis ssp. consistently associated with higher CRP and leukocyte values, indicating a more intense systemic response. Staphylococcus epidermidis was the most frequently isolated species but showed moderate inflammatory profiles, suggesting its potential role in subclinical colonization. A strong correlation between CRP on day 3 and leukocyte count (r = 0.81) confirms their combined utility in the early detection of infectious complications, while ESR appeared less dynamic and more complementary in nature. Discussion: This study highlights the significant role of intraoperative contamination and microbial virulence in shaping the postoperative inflammatory response after arthroplasty. Elevated CRP and leukocyte levels, particularly on day 3, were closely associated with pathogens known for biofilm formation and chronic infections. Despite prophylactic antibiotic use, confirmed infections still occurred, suggesting the need to reassess current protocols and enhance intraoperative contamination control. Conclusions: Pathogen presence in sterile fields during arthroplasty increases the risk of periprosthetic joint infections, often without early clinical symptoms. CRP on day 3 and leukocyte count were the most reliable early indicators of persistent inflammation.

1 September 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
NINicolas Ion
Nicolas Ion
SFSorin Radu Fleaca
Sorin Radu Fleaca
BBBogdan-Axente Bocea
Bogdan-Axente Bocea
CMCosmin Ioan Mohor
Cosmin Ioan Mohor
MRMihai-Dan Roman
Mihai-Dan Roman
Victoria BirlutiuVictoria Birlutiu
Victoria Birlutiu
Introduction: Periprosthetic joint infection (PJI) remains one of the most challenging complications following total hip arthroplasty (THA). Antibiotic-loaded bone cement (ALBC) provides high local antibiotic concentrations and is widely used in patients at increased risk of infection. Although several dual-antibiotic formulations have been investigated, their influence on the early postoperative inflammatory response has not been directly compared. Methods: In this prospective observational cohort study, 35 patients undergoing primary cemented THA between January 2025 and January 2026 were allocated to one of five ALBC regimens according to routine clinical practice: gentamicin alone, gentamicin–vancomycin, gentamicin–clindamycin, gentamicin–meropenem, or gentamicin–tobramycin (n = 7 per group). Serum C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), and leukocyte count were measured preoperatively and on postoperative Days 1, 3, and 7. Longitudinal analyses accounting for within-patient correlations were performed to assess the effects of treatment group, postoperative time, and the group × time interaction. Day-specific between-group comparisons using one-way analysis of variance (ANOVA), with eta-squared (η2) as an effect-size measure, were performed as secondary analyses, with Bonferroni adjustment applied to post-hoc pairwise comparisons. Results: All treatment groups demonstrated progressive reductions in postoperative inflammatory markers. Longitudinal analysis demonstrated significant effects of treatment group, postoperative time, and the group × time interaction for CRP and ESR (all p < 0.001). For leukocyte count, significant effects of time and the group × time interaction were observed (both p < 0.001), whereas the overall group effect was not statistically significant (p = 0.071). Secondary day-specific analyses showed significant between-group differences in CRP, with comparatively lower values observed in the gentamicin–meropenem group. Several pairwise differences in CRP and ESR remained statistically significant after Bonferroni adjustment, whereas no pairwise differences in leukocyte counts remained significant after correction. Conclusions: Different antibiotic-loaded PMMA formulations were associated with distinct early postoperative inflammatory profiles. Gentamicin–meropenem was associated with comparatively lower CRP and ESR values; however, these exploratory findings do not establish superior infection-preventive efficacy and require confirmation in larger studies.