Alicia Murga

Dr. Alicia Murga

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2023 in PLOS Computational Biology
Verified
Journal Article
Open access
PDF file
AMAlicia Murga
Alicia Murga
RBRahul Bale
Rahul Bale
CLChung-Gang Li
Chung-Gang Li
KIKazuhide Ito
Kazuhide Ito
MTMakoto Tsubokura
Makoto Tsubokura
As evidenced by the worldwide pandemic, respiratory infectious diseases and their airborne transmission must be studied to safeguard public health. This study focuses on the emission and transport of speech-generated droplets, which can pose risk of infection depending on the loudness of the speech, its duration and the initial angle of exhalation. We have numerically investigated the transport of these droplets into the human respiratory tract by way of a natural breathing cycle in order to predict the infection probability of three strains of SARS-CoV-2 on a person who is listening at a one-meter distance. Numerical methods were used to set the boundary conditions of the speaking and breathing models and large eddy simulation (LES) was used for the unsteady simulation of approximately 10 breathing cycles. Four different mouth angles when speaking were contrasted to evaluate real conditions of human communication and the possibility of infection. Breathed virions were counted using two different approaches: the breathing zone of influence and direction deposition on the tissue. Our results show that infection probability drastically changes based on the mouth angle and the breathing zone of influence overpredicts the inhalation risk in all cases. We conclude that to portray real conditions, the probability of infection should be based on direct tissue deposition results to avoid overprediction and that several mouth angles must be considered in future analyses.

26 September 2023 in Fluids
Verified
Journal Article
Open access
PDF file
YWYukun Wang
Yukun Wang
JSJingnan Sun
Jingnan Sun
MZMeng Zhao
Meng Zhao
AMAlicia Murga
Alicia Murga
SYSung-Jun Yoo
Sung-Jun Yoo
ZLZhengwei Long
Zhengwei Long
The transport and prediction of the concentration of particles in confined spaces are crucial for human well-being; this has become particularly evident during the current worldwide pandemic. Computational fluid dynamics (CFD) has been widely used for such predictions, relying on Eulerian–Eulerian (EE) and Eulerian–Lagrangian (EL) models to study particle flow. However, there is a lack of research on industrial factories. In this study, a scaled laboratory in an industrial factory was established for oil mist particles in a machining factory, and oil mist dispersion experiments were conducted under roof exhaust and mixed ventilation conditions. After that, the oil mist concentration distribution in the factory under the same working conditions was calculated by Eulerian and Lagrangian methods, and the corresponding calculation errors and resource consumption were compared. It was found that the simulation results of both methods are acceptable for mixed ventilation and roof exhaust ventilation systems. When there are more vortices in the factory, the Lagrangian method increases the computation time by more than 53% to satisfy the computational accuracy, and the computational error between the Eulerian and Lagrangian methods becomes about 10% larger. For oil mist particles with an aerodynamic diameter of 0.5 μm, both Eulerian and Lagrangian methods have reliable accuracy. Based on the same flow field, the Lagrangian method consumes more than 400 times more computational resources than the Eulerian method. This study can provide a reference for the simulation of indoor particulate transport in industrial factories.

23 June 2021 in Indoor and Built Environment
Verified
Journal Article
Closed access
PDF file
SIShun Ichimiya
Shun Ichimiya
AMAlicia Murga
Alicia Murga
SYSung-Jun Yoo
Sung-Jun Yoo
ESEisaku Sumiyoshi
Eisaku Sumiyoshi
HHHiroshi Harashima
Hiroshi Harashima
KIKazuhide Ito
Kazuhide Ito
In factories where high-risk chemical pollutants are treated, it is essential to anticipate response measures in the event of chemical pollutant leakage to minimize adverse health effects on workers. When high-risk liquid chemical pollutants are assumed to be leaked inside enclosed spaces, it becomes crucial to predict the non-uniform concentration distributions in enclosed spaces and evaluate the health impacts and risks of short-time exposure to prevent large-scale accidents. Therefore, we have developed an emergency ventilation system for controlling the inhaled contaminant dose of factory workers. In this study, assuming a worst-case scenario liquid chemical pollutant leak in an enclosed factory space, the advantages and performance of a hybrid ventilation system that combines displacement and push–pull type ventilation systems were numerically investigated. Installation of wall materials that facilitate photocatalytic oxidation (PCO) reactions for background passive concentration control was also discussed. Based on the demonstrative numerical analyses for a realistic factory space, push–pull type ventilation system was confirmed to effectively suppress chemical pollutant diffusion in enclosed spaces with a low ventilation rate. Wall materials with the PCO mechanism had a certain contribution to the control of peak concentration.

1 October 2024 in Building and Environment
Verified
Journal Article
Open access
AMAlicia Murga
Alicia Murga
RBRahul Bale
Rahul Bale
KIKazuhide Ito
Kazuhide Ito
MTMakoto Tsubokura
Makoto Tsubokura

1 September 2019 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
AMAlicia Murga
Alicia Murga
KKKazuki Kuga
Kazuki Kuga
SYSung-Jun Yoo
Sung-Jun Yoo
KIKazuhide Ito
Kazuhide Ito
Human health has been intimately linked to the indoor environment, highlighting the relevance of indoor air quality (IAQ). Although various techniques have been developed to maintain the well-being of building residents/workers, a convergence between IAQ and personal inhalation exposure risk under realistic conditions has yet to be achieved due to the heterogeneous nature of contaminant transfer. In this regard, computational fluid dynamics (CFD) is a promising tool when analysing detailed three-dimensional flow and gas-phase contaminant transport in a building. From this viewpoint, this study performs a comprehensive inhalation exposure analysis in the working environment, integrating outdoor airflow to the indoor environment of a factory under cross-ventilation for an 8-hour occupational period, a factory worker in the form of a computer simulated person (CSP) and a semi-coupled virtual respiratory tract. A physiologically-based toxicokinetic (PBTK) model has been added to the respiratory tract to predict tissue dose distribution, i.e., inhalation exposure risk. Three cases were analysed to confirm the differences between maximum/minimum and time-averaged inhaled dose for a comprehensive source-to-dose study. Results confirmed the relevance of calculated personal inhalation exposure for an accurate time-averaged intake and the danger of acute exposures at given times of a working day.

11 September 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
RBRahul Bale
Rahul Bale
AMAlicia Murga
Alicia Murga
HYHaruhiro Yamamoto
Haruhiro Yamamoto
MTMakoto Tsubokura
Makoto Tsubokura
Displacement ventilation systems can offer healthy indoor air quality (IAQ) by maintaining stratified flows that transport and expel airborne contaminants through the upper region of indoor spaces. Using large eddy simulation (LES), we investigate displacement ventilation in a generic indoor space under varying ventilation flow rates and supply–exhaust configurations. Assessing the ventilation system requires quantitative evaluation of airborne contaminants, for which CO2 concentration is typically used as a proxy. However, in this study, we show that there is both a qualitative and quantitative correlation between CO2 and airborne respiratory particles using computational particle fluid dynamics simulations. The role of the ventilation flow rate in ventilation efficacy is investigated for low values ranging from 0.01 to 0.06 m3/s, and the role of supply–exhaust configuration is assessed by considering in-line and staggered layouts. At low flow rates (0.01 to 0.04 m3/s), the ventilation system maintains a stable stratified layer within the room. Within this regime, the CO2 level in the occupied zone is inversely proportional to the ventilation rate. At higher flow rates, the ventilation transitions to a mixing regime, effectively nullifying the intended design of the system. Interestingly, the two opening configurations produce nearly identical trends, suggesting that jet strength and room geometry dominate over modest opening shifts in this setup.