Kazuhide Ito

Prof. Dr. Kazuhide Ito

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2018 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
MMMahbubul Muttakin
Mahbubul Muttakin
SMSourav Mitra
Sourav Mitra
Kyaw ThuKyaw Thu
Kyaw Thu
KIKazuhide Ito
Kazuhide Ito
BSBidyut Baran Saha
Bidyut Baran Saha

1 December 2015 in Building and Environment
Verified
Journal Article
Closed access
NPNguyen Lu Phuong
Nguyen Lu Phuong
KIKazuhide Ito
Kazuhide Ito

11 January 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
PWPing Wang
Ping Wang
WCWenhao Chen
Wenhao Chen
JLJiawen Liao
Jiawen Liao
TMToshiki Matsuo
Toshiki Matsuo
KIKazuhide Ito
Kazuhide Ito
KKKazukiyo Kumagai
Kazukiyo Kumagai
To investigate how the two main electronic (e-) cigarette solvents—propylene glycol (PG) and glycerol (GL)—modulate the formation of toxic volatile carbonyl compounds under precisely controlled temperatures in the absence of nicotine and flavor additives. PG, GL, PG:GL = 1:1 (wt/wt) mixture, and two commercial e-cigarette liquids were vaporized in a stainless steel, tubular reactor in flowing air ranging up to 318°C to simulate e-cigarette vaping. Aerosols were collected and analyzed to quantify the amount of volatile carbonyls produced with each of the five e-liquids. Significant amounts of formaldehyde and acetaldehyde were detected at reactor temperatures ≥215°C for both PG and GL. Acrolein was observed only in e-liquids containing GL when reactor temperatures exceeded 270°C. At 318°C, 2.03±0.80 μg of formaldehyde, 2.35±0.87 μg of acetaldehyde, and a trace amount of acetone were generated per milligram of PG; at the same temperature, 21.1±3.80 μg of formaldehyde, 2.40±0.99 μg of acetaldehyde, and 0.80±0.50 μg of acrolein were detected per milligram of GL. We developed a device-independent test method to investigate carbonyl emissions from different e-cigarette liquids under precisely controlled temperatures. PG and GL were identified to be the main sources of toxic carbonyl compounds from e-cigarette use. GL produced much more formaldehyde than PG. Besides formaldehyde and acetaldehyde, measurable amounts of acrolein were also detected at ≥270°C but only when GL was present in the e-liquid. At 215°C, the estimated daily exposure to formaldehyde from e-cigarettes, exceeded United States Environmental Protection Agency (USEPA) and California Office of Environmental Health Hazard Assessment (OEHHA) acceptable limits, which emphasized the need to further examine the potential cancer and non-cancer health risks associated with e-cigarette use.

19 April 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
WCWenhao Chen
Wenhao Chen
PWPing Wang
Ping Wang
KIKazuhide Ito
Kazuhide Ito
JFJeff Fowles
Jeff Fowles
DSDennis Shusterman
Dennis Shusterman
KKKazukiyo Kumagai
Kazukiyo Kumagai
To determine the effect of applied power settings, coil wetness conditions, and e-liquid compositions on the coil heating temperature for e-cigarettes with a “top-coil” clearomizer, and to make associations of coil conditions with emission of toxic carbonyl compounds by combining results herein with the literature. The coil temperature of a second generation e-cigarette was measured at various applied power levels, coil conditions, and e-liquid compositions, including (1) measurements by thermocouple at three e-liquid fill levels (dry, wet-through-wick, and full-wet), three coil resistances (low, standard, and high), and four voltage settings (3–6 V) for multiple coils using propylene glycol (PG) as a test liquid; (2) measurements by thermocouple at additional degrees of coil wetness for a high resistance coil using PG; and (3) measurements by both thermocouple and infrared (IR) camera for high resistance coils using PG alone and a 1:1 (wt/wt) mixture of PG and glycerol (PG/GL). For single point thermocouple measurements with PG, coil temperatures ranged from 322 ‒ 1008°C, 145 ‒ 334°C, and 110 ‒ 185°C under dry, wet-through-wick, and full-wet conditions, respectively, for the total of 13 replaceable coil heads. For conditions measured with both a thermocouple and an IR camera, all thermocouple measurements were between the minimum and maximum across-coil IR camera measurements and equal to 74% ‒ 115% of the across-coil mean, depending on test conditions. The IR camera showed details of the non-uniform temperature distribution across heating coils. The large temperature variations under wet-through-wick conditions may explain the large variations in formaldehyde formation rate reported in the literature for such “top-coil” clearomizers. This study established a simple and straight-forward protocol to systematically measure e-cigarette coil heating temperature under dry, wet-through-wick, and full-wet conditions. In addition to applied power, the composition of e-liquid, and the devices’ ability to efficiently deliver e-liquid to the heating coil are important product design factors effecting coil operating temperature. Precautionary temperature checks on e-cigarettes under manufacturer-recommended normal use conditions may help to reduce the health risks from exposure to toxic carbonyl emissions associated with coil overheating.

1 June 2012 in Building and Environment
Verified
Journal Article
Closed access
YFYunqing Fan
Yunqing Fan
KIKazuhide Ito
Kazuhide Ito

1 March 2014 in Journal of Wind Engineering and Industrial Aerodynamics
Verified
Journal Article
Closed access
CLCong Li
Cong Li
KIKazuhide Ito
Kazuhide Ito