Alireza Farahinia

Dr. Alireza Farahinia

Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
orcid
Department of Mechanical Engineering, University of Saskatch...

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Journal of Science: Advanced Materials and Devices
Verified
Journal Article
Open access
Alireza FarahiniaAlireza Farahinia
Alireza Farahinia
Wenjun ZhangWenjun Zhang
Wenjun Zhang
IBI. Badea
I. Badea

2 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Alireza FarahiniaAlireza Farahinia
Alireza Farahinia
Wenjun ZhangWenjun Zhang
Wenjun Zhang
Ildiko BadeaIldiko Badea
Ildiko Badea
The treatment of cancers is a significant challenge in the healthcare context today. Spreading circulating tumor cells (CTCs) throughout the body will eventually lead to cancer metastasis and produce new tumors near the healthy tissues. Therefore, separating these invading cells and extracting cues from them is extremely important for determining the rate of cancer progression inside the body and for the development of individualized treatments, especially at the beginning of the metastasis process. The continuous and fast separation of CTCs has recently been achieved using numerous separation techniques, some of which involve multiple high-level operational protocols. Although a simple blood test can detect the presence of CTCs in the blood circulation system, the detection is still restricted due to the scarcity and heterogeneity of CTCs. The development of more reliable and effective techniques is thus highly desired. The technology of microfluidic devices is promising among many other bio-chemical and bio-physical technologies. This paper reviews recent developments in the two types of microfluidic devices, which are based on the size and/or density of cells, for separating cancer cells. The goal of this review is to identify knowledge or technology gaps and to suggest future works.

18 October 2019 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
Verified
Journal Article
Closed access
PDF file
Alireza FarahiniaAlireza Farahinia
Alireza Farahinia
Wenjun ZhangWenjun Zhang
Wenjun Zhang

25 March 2020 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
Verified
Journal Article
Closed access
PDF file
Alireza FarahiniaAlireza Farahinia
Alireza Farahinia
Wenjun ZhangWenjun Zhang
Wenjun Zhang

31 August 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
Alireza FarahiniaAlireza Farahinia
Alireza Farahinia
jafar jamaatijafar jamaati
jafar jamaati
HNHamid Niazmand
Hamid Niazmand
Wenjun ZhangWenjun Zhang
Wenjun Zhang
One approach to achieve a homogeneous mixture in microfluidic systems in the quickest time and shortest possible length is to employ electroosmotic flow characteristics with heterogeneous surface properties. Mixing using electroosmotic flow inside microchannels with homogeneous walls is done primarily under the influence of molecular diffusion, which is not strong enough to mix the fluids thoroughly. However, surface chemistry technology can help create desired patterns on microchannel walls to generate significant rotational currents and improve mixing efficiency remarkably. This study analyzes the function of a heterogeneous zeta-potential patch located on a microchannel wall in creating mixing inside a microchannel affected by electroosmotic flow and determines the optimal length to achieve the desired mixing rate. The approximate Helmholtz–Smoluchowski model is suggested to reduce computational costs and simplify the solving process. The results show that the heterogeneity length and location of the zeta-potential patch affect the final mixing proficiency. It was also observed that the slip coefficient on the wall has a more significant effect than the Reynolds number change on improving the mixing efficiency of electroosmotic micromixers, benefiting the heterogeneous distribution of zeta-potential. In addition, using a channel with a heterogeneous zeta-potential patch covered by a slip surface did not lead to an adequate mixing in low Reynolds numbers. Therefore, a homogeneous channel without any heterogeneity would be a priority in such a range of Reynolds numbers. However, increasing the Reynolds number and the presence of a slip coefficient on the heterogeneous channel wall enhances the mixing efficiency relative to the homogeneous one. It should be noted, though, that increasing the slip coefficient will make the mixing efficiency decrease sharply in any situation, especially in high Reynolds numbers.

18 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Alireza FarahiniaAlireza Farahinia
Alireza Farahinia
MKMilad Khani
Milad Khani
TMTyler A. Morhart
Tyler A. Morhart
GWGarth Wells
Garth Wells
Ildiko BadeaIldiko Badea
Ildiko Badea
Wenjun ZhangWenjun Zhang
Wenjun Zhang
This paper presents a novel centrifugal microfluidic approach (so-called lab-on-a-CD) for magnetic circulating tumor cell (CTC) separation from the other healthy cells according to their physical and acquired chemical properties. This study enhances the efficiency of CTC isolation, crucial for cancer diagnosis, prognosis, and therapy. CTCs are cells that break away from primary tumors and travel through the bloodstream; however, isolating CTCs from blood cells is difficult due to their low numbers and diverse characteristics. The proposed microfluidic device consists of two sections: a passive section that uses inertial force and bifurcation law to sort CTCs into different streamlines based on size and shape and an active section that uses magnetic forces along with Dean drag, inertial, and centrifugal forces to capture magnetized CTCs at the downstream of the microchannel. The authors designed, simulated, fabricated, and tested the device with cultured cancer cells and human cells. We also proposed a cost-effective method to mitigate the surface roughness and smooth surfaces created by micromachines and a unique pulsatile technique for flow control to improve separation efficiency. The possibility of a device with fewer layers to improve the leaks and alignment concerns was also demonstrated. The fabricated device could quickly handle a large volume of samples and achieve a high separation efficiency (93%) of CTCs at an optimal angular velocity. The paper shows the feasibility and potential of the proposed centrifugal microfluidic approach to satisfy the pumping, cell sorting, and separating functions for CTC separation.