Ali Sayghe

Dr. Ali Sayghe

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2020 in IET Smart Grid
Verified
Journal Article
Open access
PDF file
ASAli Sayghe
Ali Sayghe
YHYaodan Hu
Yaodan Hu
IZIoannis Zografopoulos
Ioannis Zografopoulos
XLXiaoRui Liu
XiaoRui Liu
RDRaj Gautam Dutta
Raj Gautam Dutta
CKCharalambos Konstantinou
Charalambos Konstantinou
Over the last decade, the number of cyber attacks targeting power systems and causing physical and economic damages has increased rapidly. Among them, false data injection attacks (FDIAs) are a class of cyber‐attacks against power grid monitoring systems. Adversaries can successfully perform FDIAs to manipulate the power system state estimation (SE) by compromising sensors or modifying system data. SE is an essential process performed by the energy management system towards estimating unknown state variables based on system redundant measurements and network topology. SE routines include bad data detection algorithms to eliminate errors from the acquired measurements, e.g. in case of sensor failures. FDIAs can bypass BDD modules to inject malicious data vectors into a subset of measurements without being detected, and thus manipulate the results of the SE process. To overcome the limitations of traditional residual‐based BDD approaches, data‐driven solutions based on machine learning algorithms have been widely adopted for detecting malicious manipulation of sensor data due to their fast execution times and accurate results. This study provides a comprehensive review of the most up‐to‐date machine learning methods for detecting FDIAs against power system SE algorithms.

2 August 2020
Verified
Conference Paper
Closed access
ASAli Sayghe
Ali Sayghe
JZJunbo Zhao
Junbo Zhao
CKCharalambos Konstantinou
Charalambos Konstantinou
Cyberattacks against critical infrastructures, including power systems, are increasing rapidly. False Data Injection Attacks (FDIAs) are among the attacks that have been demonstrated to be effective and have been getting more attention over the last years. FDIAs can manipulate measurements to perturb the results of power system state estimation without being detected, leading to potentially severe outages. In order to protect against FDIAs, several machine learning algorithms have been proposed in the literature. However, such methods are susceptible to adversarial examples which could significantly reduce their detection accuracy. In this paper, we examine the effects of adversarial examples on FDIAs detection using deep learning algorithms. Specifically, the impacts on Multilayer Perceptron (MLP) against two different adversarial attacks are investigated, namely the Limited-memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS) and the Jacobian-based Saliency Map Attack (JSMA). Numerical results tested on the IEEE 14-bus system using load data collected from the New York Independent System Operator (NYISO) demonstrate the effectiveness of the proposed methods.

11 August 2025 in Sensors
Verified
Journal Article
Open access
PDF file
ASAli Sayghe
Ali Sayghe
The convergence of operational technology (OT) and information technology (IT) in industrial environments, such as water treatment plants, has significantly increased the attack surface of Supervisory Control and Data Acquisition (SCADA) systems. Traditional intrusion detection systems (IDS), which focus solely on network traffic, often fail to detect stealthy, process-level attacks. This paper proposes a Digital Twin-driven Intrusion Detection (DT-ID) framework that integrates high-fidelity process simulation, real-time sensor modeling, adversarial attack injection, and hybrid anomaly detection using both physical residuals and machine learning. We evaluate the DT-ID framework using a simulated water treatment plant environment, testing against false data injection (FDI), denial-of-service (DoS), and command injection attacks. The system achieves a detection F1-score of 96.3%, a false positive rate below 2.5%, and an average detection latency under 500 ms, demonstrating substantial improvement over conventional rule-based and physics-only IDS in identifying stealthy anomalies. Our findings highlight the potential of cyber-physical digital twins to enhance SCADA security in critical infrastructure. In the following sections, we present the motivation and approach underlying this framework.

1 February 2020
Verified
Conference Paper
Closed access
ASAli Sayghe
Ali Sayghe
OAOlugbenga Moses Anubi
Olugbenga Moses Anubi
CKCharalambos Konstantinou
Charalambos Konstantinou
The number of cyber-attacks targeting power system infrastructures is increasing at an alarming rate. Among them, False Data Injection Attacks (FDIAs) can disturb the normal operation of state estimation routines in power systems and potentially lead to outages. Several studies utilize machine learning algorithms to detect FDIAs with high accuracy. However, such algorithms can be susceptible to adversarial examples able to lower the accuracy of the detection model. Adversarial examples are crafted inputs intentionally designed to falsify machine learning algorithms. In this paper, we examine the effect of adversarial examples on machine learning algorithms that are used to detect FDIAs in state estimation. Specifically, we demonstrate the impact on Support Vector Machines (SVM) and Multilayer Perceptrons (MLP) against poisoning and evasion adversarial attacks. The algorithms are tested on IEEE 14 bus system using load data collected from the New York Independent System Operator (NYISO).

11 January 2026 in Energies
Verified
Journal Article
Open access
PDF file
ASAli Sayghe
Ali Sayghe
MMMohammed Ahmed Mousa
Mohammed Ahmed Mousa
SBSalem Batiyah
Salem Batiyah
AHAbdulrahman Z Husawi
Abdulrahman Z Husawi
MAMansour Jumayyi Almuwallad
Mansour Jumayyi Almuwallad
The rapid integration of renewable energy sources and increasing complexity of modern power grids demand advanced forecasting tools capable of simultaneously predicting multiple interconnected variables. While time series foundation models (TSFMs) have demonstrated remarkable zero-shot forecasting capabilities across diverse domains, their application in power grid operations remains limited due to complex coupling relationships between load, price, emissions, and renewable generation. This paper proposes GridFM, a novel physics-informed foundation model specifically designed for multi-task energy forecasting in power systems. GridFM introduces four key innovations: (1) a FreqMixer adaptation layer that transforms pre-trained foundation model representations to power-grid-specific patterns through frequency domain mixing without modifying base weights; (2) a physics-informed constraint module embedding power balance equations and zonal grid topology using graph neural networks; (3) a multi-task learning framework enabling joint forecasting of load demand, locational-based marginal prices (LBMP), carbon emissions, and renewable generation with uncertainty-weighted loss functions; and (4) an explainability module utilizing SHAP values and attention visualization for interpretable predictions. We validate GridFM using over 10 years of real-time data from the New York Independent System Operator (NYISO) at 5 min resolution, comprising more than 10 million data points across 11 load zones. Comprehensive experiments demonstrate that GridFM achieves state-of-the-art performance with an 18.5% improvement in load forecasting MAPE (achieving 2.14%), a 23.2% improvement in price forecasting (achieving 7.8% MAPE), and a 21.7% improvement in emission prediction compared to existing TSFMs including Chronos, TimesFM, and Moirai-MoE. Ablation studies confirm the contribution of each proposed component. The physics-informed constraints reduce physically inconsistent predictions by 67%, while the multi-task framework improves individual task performance by exploiting inter-variable correlations. The proposed model provides interpretable predictions supporting the Climate Leadership and Community Protection Act (CLCPA) 2030/2040 compliance objectives, enabling grid operators to make informed decisions for sustainable energy transition and carbon reduction strategies.

26 February 2026 in Smart Cities
Verified
Journal Article
Open access
PDF file
MMMohammed Ahmed Mousa
Mohammed Ahmed Mousa
ASAli Sayghe
Ali Sayghe
SBSalem Batiyah
Salem Batiyah
AHAbdulrahman Z Husawi
Abdulrahman Z Husawi
Dynamic Wireless Power Transfer (DWPT) is emerging as critical smart city infrastructure for sustainable urban mobility, enabling electric vehicle charging while driving. However, DWPT introduces complex fault scenarios requiring intelligent monitoring. Existing fault diagnosis approaches for wireless power transfer systems face three key complexities: (1) they are limited to static charging with only 2–4 fault categories, failing to address the time-varying coupling dynamics and segmented coil handover transients inherent in dynamic charging; (2) they lack integration with the host distribution grid, ignoring grid-side disturbances that propagate to charging stations; and (3) they offer only reactive detection without predictive capability for incipient fault management. This paper presents a deep neural network (DNN)-based fault diagnosis framework utilizing multi-station sensor fusion for DWPT systems integrated with the IEEE 13-bus distribution network to address these limitations. The system monitors 36 sensor features across three charging stations, employing feature-level concatenation with station-specific normalization for multi-station fusion, achieving 97.85% classification accuracy across eight fault types. Unlike static charging, the framework explicitly models time-varying coupling dynamics due to vehicle motion, including segmented coil handover effects. A digital twin provides dual-horizon prediction: long-term forecasting (24–72 h) for incipient faults and real-time detection under 50 ms for critical protection, with fault probability outputs and ranked fault lists enabling actionable maintenance decisions. The DNN outperforms SVM (92.45%), Random Forest (94.82%), and LSTM (96.54%) with statistical significance (p<0.001), while maintaining model inference latency of 4.2 ms, suitable for edge deployment. Circuit-based analysis provides analytical justification for fault signatures, and practical parameter acquisition methods enable real-world implementation. Five case studies validate robustness across highway, urban, and grid disturbance scenarios with detection accuracies exceeding 95%.