Alok Shah

Dr. Alok Shah

Cardiology, Sir H.N. Reliance Foundation Hospital and Research Centre, Mumbai, Mahārāshtra, International
orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Alok ShahAlok Shah
Alok Shah
AGAmr Gamal
Amr Gamal
HAHesham Abdelaziz
Hesham Abdelaziz
MLMatthew Luckie
Matthew Luckie
AWAndrew Wiper
Andrew Wiper
TCTawfiq Choudhury
Tawfiq Choudhury
Transcatheter Aortic Valve Implantation/Replacement (TAVI/TAVR) has come a long way since the first-in-human implant by Prof Cribier & colleagues in 2002. Initially a consideration for inoperable/high-surgical-risk patients, TAVI is now indicated in patients with severe tricuspid aortic stenosis and suitable anatomy aged 70 or higher. This has been made possible due to improvements in preprocedural planning, performance upgrades to and evolution of transcatheter heart valve (THV) systems and increasing operator experience. Younger age at index implantation, complexities of redo TAVI planning and methods to improve THV durability are the next frontiers. This review summarizes these advancements while emphasizing preprocedural planning, current guidelines, and individualized device selection, with a brief note on polymeric heart valves—developed to overcome the disadvantageous bioprosthetic dysfunction seen with current THVs.

21 August 2026 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Open access
PDF file
HKHilal Khan
Hilal Khan
MAMohamed Ali
Mohamed Ali
AIAbdalazeem Ibrahem
Abdalazeem Ibrahem
KRKarim Ratib
Karim Ratib
NZNur Ilia Mohd Zaki
Nur Ilia Mohd Zaki
MFMohamed Farag
Mohamed Farag
Introduction: The prevalence of bioprosthetic aortic valve failure is increasing due to the broader use of bioprosthetic valves, both surgical and transcatheter, and an ageing population. Registry data indicate a higher risk of coronary obstruction and elevated gradients following valve‐in‐valve transcatheter aortic valve implantation (TAVI). We report outcomes of the Allegra transcatheter heart valve system in valve‐in‐valve TAVI. Methods: In this retrospective multicentre cohort study, all patients undergoing valve‐in‐valve TAVI with the Allegra system between 2019 and 2025 at five UK centers were included. The combined primary outcomes were technical success, device success, and early safety at 30 days, as per the VARC‐3 (Valve Academic Research Consortium‐3) criteria. A key secondary outcome was all‐cause mortality at the longest documented follow‐up. Results: A total of 106 patients underwent valve‐in‐valve TAVI. The mean age was 79 ± 6 years, with 57.5% being female. Almost half of the patients had an index valve ≤ 21 mm, with an STS (Society of Thoracic Surgery) score of 7.1% (5.1–12.0). The post‐implant aortic valve mean pressure gradient was 12 ± 6 mmHg, and the mean valve area was 1.7 ± 0.5 cm 2 . The combined primary outcomes were technical success of 86.8% (CI 80.3%–93.2%), device success of 75.5% (CI 67.3%–83.7%), and early safety of 86.8% (CI 80.3%–93.2%). All‐cause mortality at 30 days was 0%. All‐cause mortality occurred in 6.6% at a median follow‐up of 15 months. Conclusions: The Allegra TAVI system demonstrates promising technical and device success rates, with early safety and good post‐implant haemodynamic performance in high‐risk patients undergoing valve‐in‐valve TAVI. Larger randomized trials are needed to confirm these results.

6 May 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
Alok ShahAlok Shah
Alok Shah
AGAmr Gamal
Amr Gamal
HAHesham Abdelaziz
Hesham Abdelaziz
MLMatthew Luckie
Matthew Luckie
AWAndrew Wiper
Andrew Wiper
TCTawfiq Choudhury
Tawfiq Choudhury
Transcatheter Aortic Valve Implantation/ Replacement (TAVI/TAVR) has come a long was since the first in human implant done by Prof Cribier & colleagues in 2002. Initially a consideration in inoperable/ high surgical risk patients, TAVI is now indicated in patients with severe tricuspid aortic stenosis and suitable anatomy aged 70 or higher. This has been possible due to improvements in pre procedural planning, performance upgrades & evolution of transcatheter heart valve (THV) systems and increasing operator experience. Considering improving longevity and relatively younger ages at index implantation, complexities of redo TAVI planning and methods to improve THV durability are the next frontiers. This review summarizes these advancements while emphasizing on pre procedural planning, current guidelines, individualized device selection with a brief note on polymeric heart valves - developed to overcome the disadvantageous bioprosthetic dysfunction seen with current THVs.