Alvaro Fanlo-Zarazaga

Mr. Alvaro Fanlo-Zarazaga

GIMSO
+1
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Archivos de la Sociedad Española de Oftalmología
Verified
Journal Article
Open access
Alvaro Fanlo-ZarazagaAlvaro Fanlo-Zarazaga
Alvaro Fanlo-Zarazaga
JVJ. Gutiérrez Vásquez
J. Gutiérrez Vásquez
VRV. Pueyo Royo
V. Pueyo Royo
Congenital colour vision deficiencies affect 8% of the male and 0.5% of the female population. The study of colour vision is a complex process due to several factors: the psychophysics of vision itself, the difficulty to establish mathematical models for its analysis, the vague correlation of results between different tests, and the influence of external factors such as lighting, the tests condition, or the experience of the examiner and the patient. In the present document, a simplified review was carried out on the main colour vision tests available in clinical practice. Once a filtered preliminary review was made of the bibliography related to the study of colour vision using the PubMed search tool, the most used tests in clinical practice were selected according to their frequency of use and the purpose for which they were applied. A bibliographic study was then carried out on each particular test according to the design of the shown stimuli, its target population, and its sensitivity and specificity. From the 95 publications found using the PubMed search tool, in 41 of them, colour tests were used by researchers in their methodology. From the 64 colour tests used, 19 of them were different (with 4 of them being different tests adapted by research groups, and 2 of them carried out online). The most used tests were the following: Ishihara test (10.88%), Farnsworth-Munsell (7.04%), Farnsworth-Munsell 100 Hue (6.4%), Cambridge Colour Test (3.84%), Hardy-Rand-Rittler (3.2%), tests developed by the groups (2.56%), the Anomaloscope (1.28%), the online tests (1.28%) and, finally, Colour Assessment and Diagnosis (0.64%), Pflüger Trident Colour Plates (0.64%), Toothguide Training Box (0.64%), Lanthony Desaturated D-15 (0.64%), City University Test (0.64%), Universal Colour Discrimination Test (0.64%), and Rabin Cone Contrast Test (0.64%). The Anomaloscope is the "gold standard" in terms of colour vision testing, despite its incompatibility with daily clinical practice. It is fairly complex to use, difficult to understand for children, and its practice requires having the time available. Nevertheless, it is possible to reach an accurate approximation through the combination of some of the tests listed in this article. The above mentioned tests are a good alternative to determine the presence of dyschromatopsia in settings closer to daily clinical practice or in less controlled settings than a clinical study. The major drawback among the wide range of tests available for the study of colour vision is the difficulty to compare results between tests, since units of the reported data are usually different, and experience is required for its correct interpretation. Currently, there is no consensus on which colour test is the most complete. It is, therefore, advisable to use at least 2 tests in order to ensure diagnoses, and have more extensive information about the visual perception of patients.

1 January 2019 in Archivos de la Sociedad Española de Oftalmología (English Edition)
Verified
Journal Article
Closed access
Alvaro Fanlo-ZarazagaAlvaro Fanlo-Zarazaga
Alvaro Fanlo-Zarazaga
JVJ. Gutiérrez Vásquez
J. Gutiérrez Vásquez
VRV. Pueyo Royo
V. Pueyo Royo

24 December 2021 in Brain Sciences
Verified
Journal Article
Open access
PDF file
IGIrene Altemir Gómez
Irene Altemir Gómez
AEAdrián Alejandre Escriche
Adrián Alejandre Escriche
Alvaro Fanlo-ZarazagaAlvaro Fanlo-Zarazaga
Alvaro Fanlo-Zarazaga
MOMarta Ortin
Marta Ortin
MRMaría Teresa Pérez Roche
María Teresa Pérez Roche
VPVictoria Pueyo
Victoria Pueyo
Background: To quantify development of gaze stability throughout life during short and long fixational tasks using eye tracking technology. Methods: Two hundred and fifty-nine participants aged between 5 months and 77 years were recruited along the study. All participants underwent a complete ophthalmological assessment. Fixational behavior during long and short fixational tasks was analyzed using a DIVE (Device for an Integral Visual Examination), a digital test assisted with eye tracking technology. The participants were divided into ten groups according to their age. Group 1, 0–2 years; group 2, 2–5 years; group 3, 5–10 years; group 4, 10–20 years; group 5, 20–30 years; group 6, 30–40 years; group 7, 40–50 years; group 8, 50–60 years; group 9, 60–70 years; and group 10, over 70 years. Results: Gaze stability, assessed by logBCEA (log-transformed bivariate contour ellipse area), improved with age from 5 months to 30 years (1.27 vs. 0.57 deg2 for long fixational task, 0.73 vs. −0.04 deg2 for short fixational task), while fixations tend to be longer (1.95 vs. 2.80 msec for long fixational tasks and 0.80 vs. 1.71 msec for short fixational tasks). All fixational outcomes worsened progressively from the fifth decade of life. Log-transformed bivariate contour ellipse area (0.79, 0.83, 0.91, 1.42 deg2 for long fixational task and 0.01, 0.18, 0.28, 0.44 deg2 for short fixational task, for group 7, 8, 9, and 10 respectively). Stimuli features may influence oculomotor performance, with smaller stimuli providing prolonged fixations. Conclusions: Fixational behavior can be accurately assessed from 5 months of age using a DIVE. We report normative data of gaze stability and duration of fixations for every age group. Currently available technology may increase the accuracy of our visual assessments at any age.

Santiago GascónSantiago Gascón
Santiago Gascón
Ricardo Fueyo-DíazRicardo Fueyo-Díaz
Ricardo Fueyo-Díaz
LBLuis Borao
Luis Borao
MLMichael Leiter
Michael Leiter
Alvaro Fanlo-ZarazagaAlvaro Fanlo-Zarazaga
Alvaro Fanlo-Zarazaga
Alejandra Aguilar-LatorreAlejandra Aguilar-Latorre
Alejandra Aguilar-Latorre
Journalists are at particular risk of work-related stress and burnout. The objective of this study is to describe and analyze the principal factors involved in the appearance of burnout in communication professionals, as well as the possible interactions between them and with self-reported health, and to observe whether the variables involved are the same in different types of environments. To achieve this objective, 292 participants answered the following measurement instruments: Demographic and labor datasheet; Maslach Burnout Inventory (MBI General survey); Areas of Worklife Scale (AWS); and General Health Questionnaire (GHQ -12). The results were the following: Emotional Exhaustion (EE) shows direct correlation and statistical significance with the other two burnout dimensions, Depersonalization (DP) and Personal Accomplishment (PA), also with health perception variables and inverse and statistical significance with the workload, control, rewards, community, fairness, and values. A multiple linear regression model shows workload and values as inverse EE predictors, which confirms a burnout process in which EE contributes as the main dimension in DP and is shown to be a precursor of PA, itself. When comparing different types of media, journalists who work in institutional press offices presented significantly lower scores in PA and higher in control, rewards, community, justice, and values. Therefore, further research should be carried out in order to analyze the protective role of these variables regarding PA and burnout.

17 February 2020 in BMJ Open
Verified
Journal Article
Open access
PDF file
VPVictoria Pueyo
Victoria Pueyo
TPTeresa Pérez-Roche
Teresa Pérez-Roche
EPEsther Prieto
Esther Prieto
OCOlimpia Castillo
Olimpia Castillo
IGInmaculada Gonzalez
Inmaculada Gonzalez
BMBelen Masia
Belen Masia
Introduction Around 70% to 80% of the 19 million visually disabled children in the world are due to a preventable or curable disease, if detected early enough. Vision screening in childhood is an evidence-based and cost-effective way to detect visual disorders. However, current screening programmes face several limitations: training required to perform them efficiently, lack of accurate screening tools and poor collaboration from young children. Some of these limitations can be overcome by new digital tools. Implementing a system based on artificial intelligence systems avoid the challenge of interpreting visual outcomes. The objective of the TrackAI Project is to develop a system to identify children with visual disorders. The system will have two main components: a novel visual test implemented in a digital device, DIVE (Device for an Integral Visual Examination); and artificial intelligence algorithms that will run on a smartphone to analyse automatically the visual data gathered by DIVE. Methods and analysis This is a multicentre study, with at least five centres located in five geographically diverse study sites participating in the recruitment, covering Europe, USA and Asia. The study will include children aged between 6 months and 14 years, both with normal or abnormal visual development. The project will be divided in two consecutive phases: design and training of an artificial intelligence (AI) algorithm to identify visual problems, and system development and validation. The study protocol will consist of a comprehensive ophthalmological examination, performed by an experienced paediatric ophthalmologist, and an exam of the visual function using a DIVE. For the first part of the study, diagnostic labels will be given to each DIVE exam to train the neural network. For the validation, diagnosis provided by ophthalmologists will be compared with AI system outcomes. Ethics and dissemination The study will be conducted in accordance with the principles of Good Clinical Practice. This protocol was approved by the Clinical Research Ethics Committee of Aragón, CEICA, on January 2019 (Code PI18/346). Results will be published in peer-reviewed journals and disseminated in scientific meetings. Trial registration number ISRCTN17316993.

11 February 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
Alvaro Fanlo-ZarazagaAlvaro Fanlo-Zarazaga
Alvaro Fanlo-Zarazaga
JEJosé Ignacio Echevarría
José Ignacio Echevarría
JPJuan Pinilla
Juan Pinilla
AEAdrián Alejandre Escriche
Adrián Alejandre Escriche
MRMaría Teresa Pérez Roche
María Teresa Pérez Roche
VPVictoria Pueyo
Victoria Pueyo
Although color vision deficiencies are very prevalent, there are no ideal methods for assessing color vision in all environments. We compared a new digital and automated method that quantifies color perception for the three protan, deutan, and tritan axes with two of the most commonly used color tests in daily practice: the Ishihara 38 plates test and the Farnsworth–Munsell 100-Hue test. One hundred patients underwent a triple examination composed of the new DIVE Color Test, the Ishihara test, and the Farnsworth–Munsell 100-Hue test. The DIVE Color Test was performed twice in forty participants to assess its repeatability. In the trichromatic group, the mean age stood at 20.57 ± 9.22 years compared with 25.99 ± 15.86 years in the dyschromatic group. The DIVE and Ishihara tests exhibited excellent agreement in identifying participants with color deficiency (Cohen’s kappa = 1.00), while it was 0.81 when comparing DIVE and Farnsworth. The correlation between the global perception values of Farnsworth (TES) and DIVE (GCS) was 0.80. The repeatability of the DIVE Color Test was high according to Bland–Altman analysis with an intraclass correlation coefficient of 0.83. According to Ishihara, the DIVE Color Test proved to be an effective and reproducible tool for red–green color vision deficiency detection, capable of determining the severity of the defect in each of the three axes faster and more accurately than both Ishihara and Farnsworth.