In this paper, we present the development and the validation of a novel index of nociception/anti-nociception (N/AN) based on skin impedance measurement in time and frequency domain with our prototype AnspecPro device. The primary objective of the study was to compare the Anspec-PRO device with two other commercial devices (Medasense, Medstorm). This comparison was designed to be conducted under the same conditions for the three devices. This was carried out during total intravenous anesthesia (TIVA) by investigating its outcomes related to noxious stimulus. In a carefully designed clinical protocol during general anesthesia from induction until emergence, we extract data for estimating individualized causal dynamic models between drug infusion and their monitored effect variables. Specifically, these are Propofol hypnotic drug to Bispectral index of hypnosis level and Remifentanil opioid drug to each of the three aforementioned devices. When compared, statistical analysis of the regions before and during the standardized stimulus shows consistent difference between regions for all devices and for all indices. These results suggest that the proposed methodology for data extraction and processing for AnspecPro delivers the same information as the two commercial devices.
Tissue hysteresivity is an important marker for determining the onset and progression of respiratory diseases, calculated from forced oscillation lung function test data. This study aims to reduce the number and duration of required measurements by combining multivariate data from various sensing devices. We propose using the Forced Oscillation Technique (FOT) lung function test in both a low-frequency prototype and the commercial RESMON device, combined with continuous monitoring from the Equivital (EQV) LifeMonitor and processed by artificial intelligence (AI) algorithms. While AI and deep learning have been employed in various aspects of respiratory system analysis, such as predicting lung tissue displacement and respiratory failure, the prediction or forecasting of tissue hysteresivity remains largely unexplored in the literature. In this work, the Long Short-Term Memory (LSTM) model is used in two ways: (1) to estimate the hysteresivity coefficient using heart rate (HR) data collected continuously by the EQV sensor, and (2) to forecast values by first predicting the heart rate from electrocardiogram (ECG) data. Our methodology involves a rigorous two-hour measurement protocol, with synchronized data collection from the EQV, FOT, and RESMON devices. Our results demonstrate that LSTM networks can accurately estimate the tissue hysteresivity parameter , achieving an of 0.851 and a mean squared error (MSE) of 0.296 for estimation, and forecast with an of 0.883 and an MSE of 0.528, while significantly reducing the number of required measurements by a factor of three (i.e., from ten to three) for the patient. We conclude that our novel approach minimizes patient effort by reducing the measurement time and the overall ambulatory time and costs while highlighting the potential of artificial intelligence methods in respiratory monitoring.
Lipophilic anesthetic drugs accumulate in adipose tissue, leading to delayed release and prolonged effects, particularly in obese patients. This study proposes two novel physiologically motivated pharmacokinetic (PK) models to address these dynamics. The first is an augmented model with a trap compartment to simulate retention, and the second is a fractional-order model using Partial-Caputo derivatives to capture memory effects. By applying a discrete-time Euler method to the augmented model, we reveal an inherent fading memory behavior, where the current drug release depends on a weighted influence of past drug concentrations in fat. Both models are integrated into a PK/PD framework. Their behavior is first explored in a single-input single-output (SISO) case using simulated Bispectral Index (BIS) responses under three common dosing protocols: single bolus, repeated boluses, and continuous infusion. Evaluation against real clinical data is then performed in a multiple-input single-output (MISO) case, where the simulated BIS responses are compared to recorded BIS measurements from a representative obese patient under total intravenous anesthesia (TIVA). During the awakening phase, both the augmented and fractional-order models reduce BIS prediction error compared to the classical model. The augmented model lowers RMSE by 22.5% (from 10.38 to 8.04), while the fractional model achieves a 21.4% reduction (to 8.16) (based on one obese patient case). Sensitivity analysis confirms the impact of the fractional-order parameter ( $$\alpha _{31}$$ ) on long-term BIS dynamics. These results and proposed models illustrate the potential role of memory-aware PK models for advanced patient-specific digital twin systems in healthcare.
The integration of information technology and control engineering has significantly increased in clinical practice research, especially in the management of drug dosing for general anaesthesia. The main focus of the research is to achieve a personalised control of the Depth of Hypnosis based on a novel approach. The primary objective is to regulate the Bispectral Index by administering Propofol during the hypnotic phase of anaesthesia. A fractional order time delay model is proposed to replace the conventional PK-PD model. This model is estimated online during the induction phase. A fractional order Proportional-Integral-Derivative (PID) controller is then individually tuned for each patient. The closed loop simulation results demonstrate that the proposed controllers effectively minimise undershoot and achieve a short time to reach the desired time-to-target for the majority of the patients. The analysis indicates that the proposed controller is capable of maintaining the BIS signal within a safe range. Comparative analyses with similar research are provided to effectively contextualise this study within the existing literature. Disturbance rejection tests during the maintenance phase are performed to demonstrate the effectiveness of personalised control. The online adaptation that this research brings, compared to the previous attempts, allows for significantly improved results for the hypnosis phase.
The research field of clinical practice has experienced a substantial increase in the integration of information technology and control engineering, which includes the management of medication administration for general anaesthesia. The invasive nature of input signals is the reason why autotuning methods are not widely used in this research field. This study proposes a non-invasive method using small-amplitude sine tests to estimate patient parameters, which allows the design of a personalised controller using an autotuning principle. The primary objective is to regulate the Bispectral Index through the administration of Propofol during the maintenance phase of anaesthesia, using a personalised fractional-order PID. This work aims to demonstrate the effectiveness of personalised control, which is facilitated by the proposed sine-based method. The closed-loop simulation results demonstrate the efficiency of the proposed approach.