Amarnathvarma Angani

Dr. Amarnathvarma Angani

Senior researcher
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2022 in Applied Thermal Engineering
Verified
Journal Article
Closed access
AAAmarnathvarma Angani
Amarnathvarma Angani
HKHyeon-Woo Kim
Hyeon-Woo Kim
MHMyeong-Hwan Hwang
Myeong-Hwan Hwang
EKEugene Kim
Eugene Kim
KKKyoung-Min Kim
Kyoung-Min Kim
HCHyun-Rok Cha
Hyun-Rok Cha

24 June 2024 in Energy
Verified
Journal Article
Closed access
TTTeressa Talluri
Teressa Talluri
AAAmarnathvarma Angani
Amarnathvarma Angani
KSKyoojae Shin
Kyoojae Shin
MHMyeong-Hwan Hwang
Myeong-Hwan Hwang
HCHyun-Rok Cha
Hyun-Rok Cha

1 January 2020
Verified
Conference Paper
Closed access
JLJunchan Lee
Junchan Lee
AAAmarnathvarma Angani
Amarnathvarma Angani
TTTeressa Thalluri
Teressa Thalluri
KSKyoo Jae Shin
Kyoo Jae Shin
This paper is about the development of mobile app for integrated control and real time monitoring of smart fish farm based on IoT. Water processing had controlled an important role in the recirculating smart fish farm. The proposed smart fish farm consists of Water Tank1, Water Tank2, Balancing Tank and RAS. In this aquaculture the water flow process is regulated by the PID controller along with water level ultrasonic sensors, water temperature sensors, DO and pH sensors. The sensors data were collected and stored in the lab servers as big data. This designed aquaculture system operates on manual mode, automatic mode and remote mode by using mobile. To verify the performance of the designed system, the field tests were conducted in Future Creative Technology Research Institute of Busan University of Foreign Studies. It was satisfied the performance of smart fish farm.

1 May 2017
Verified
Conference Paper
Closed access
KSKyoo Jae Shin
Kyoo Jae Shin
AAAmarnathvarma Angani
Amarnathvarma Angani
These days most of aquaculture industries using water management system which is operated manually, in this case wasting high quantity of water and spending more money for maintenance purpose. From this point of view we proposed new aquaculture system with electrical valve, that system is called a vertical aquarium management system. The purpose of the electrical valve is to regulate the flow and to maintain the constant temperature of water in the aquarium. After attaining the required water level and temperature level, the electrical valve will be automatically closed to stop the water inflow. This electrical valve is controlled by level sensors and temperature sensors that are attached to the tanks. Advantages of the electrical valve are Self-cleaning and low maintenance cost of the aquarium. This process is operated by a micro-controller. This electrical valve is specially designed to meet the requirements of the vertical aquarium energy management system (VAEMS).

6 December 2019 in Sensors and Materials
Verified
Journal Article
Open access
AAAmarnathvarma Angani
Amarnathvarma Angani
JLJun Charn Lee
Jun Charn Lee
KSKyoo Jae Shin
Kyoo Jae Shin

7 April 2022 in Energies
Verified
Journal Article
Open access
PDF file
HKHyeon-Woo Kim
Hyeon-Woo Kim
AAAmarnathvarma Angani
Amarnathvarma Angani
EKEugene Kim
Eugene Kim
MHMyeong Hwan Hwang
Myeong Hwan Hwang
KKKyoungmin Kim
Kyoungmin Kim
HCHyun-Rok Cha
Hyun-Rok Cha
The market for electric vehicles is growing rapidly. Among them, the demand for a dual motor type 4 WD (Four -Wheel Driving) system is increasing. In this paper, we present the Torque Matching Strategy (TMS) method to select the optimal torque distribution ratio for dual motors. The TMS controller operates to set the optimal efficiency point by linearizing the drive efficiency combination of the two motors. Driving simulation and testing were performed through five drive cycles in the driver model interworking environment implemented in MATLAB and Carsim. The optimal distribution ratio was derived according to the front and rear gear ratios under the load condition, and the driving was verified by comparing it with the TMS control method. The efficiency was numerically verified by comparing the power loss of the driving motor. It reduced up to 34% in Urban Dynamometer Driving Schedule and up to 56.3% in Highway fuel efficiency test. The effectiveness of the TMS control method was demonstrated through the distribution rate trend based on the operation cycle and power loss.