This paper describes the performance of a system for dynamic measurements of pressure and shear forces over the entire plantar surface of the foot. During human locomotion, mechanical stress at the plantar surface is 3D: pressure acting vertically and shear stress acting longitudinally and laterally. The system described here offers gait, foot deformity, diabetic ulceration, and foot-ankle kinetics researchers a means to obtain the full 3D data that is missing in most current research efforts. Surface Stress Sensitive Film ™ (S3F) provides the sensing element for this measurement device. S3F is an incompressible elastic film that deforms in response to applied forces. Upon removal of the forces, the film returns to its original shape. The dynamic, 3D deformations are captured with a digital camera. The measured deformations can be analyzed directly, since they are proportional to the applied forces, or used as inputs to a finite element model of the film to reconstruct the pressure and shear force values. System performance is evaluated using both a standard form and human foot contact. The fundamental approach involves comparing the integrated normal and shear loads from the S3F-based sensor to the measurements provided by a force plate. The results showed high linearity (<3% nonlinearity), low uncertainty (<4%), low cross talk (<3%), high spatial resolution (1.6 mm 2 ), no loss of fidelity at walking speeds with a 45 Hz sampling rate, and good repeatability for human foot contact measurements.

13 June 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
Amelia HoweAmelia Howe
Amelia Howe
ZCZhanda Chen
Zhanda Chen
KGKyle Golobish
Kyle Golobish
VMVictoria R. Miduri
Victoria R. Miduri
DLDerrick Liu
Derrick Liu
SNStephan Nieuwoudt
Stephan Nieuwoudt
(1) Background: Medical devices, especially neuromodulation devices, are often explanted for a variety of reasons. The removal process imparts significant forces on these devices, which may result in device fracture and tissue trauma. We hypothesized that a device’s form factor interfacing with tissue is a major driver of the force required to remove a device, and we isolated helical and linear electrode structures as a means to study atraumatic removal. (2) Methods: Ductile linear and helical microwire structure electrodes were fabricated from either Gold (Au) or Platinum–Iridium (Pt-Ir, 90-10). Removal forces were captured from synthetic gel models and following chronic implantation in rodent and porcine models. Devices were fully implanted in the animal models, requiring a small incision (<10 mm) and removal via tissue forceps. (3) Results: Helical devices were shown to result in significantly lower maximal removal forces in both synthetic gel and rodent studies compared to their linear counterparts. Chronically (1 yr.), the maximal removal force of helical devices remained under 7.30 N, for which the Platinum–Iridium device’s tensile failure force was 32.90 ± 2.09 N, resulting in a safety factor of 4.50. (4) Conclusions: An open-core helical structure that can freely elongate was shown to result in reduced removal forces both acutely and chronically.