Amer Zakaria

Dr. Amer Zakaria

American University of Sharjah, Sharjah city, United Arab Emirates
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
NANour AlSawaftah
Nour AlSawaftah
SESalma El-Abed
Salma El-Abed
SDSalam Dhou
Salam Dhou
Amer ZakariaAmer Zakaria
Amer Zakaria
Breast cancer is the most commonly diagnosed cancer type and is the leading cause of cancer-related death among females worldwide. Breast screening and early detection are currently the most successful approaches for the management and treatment of this disease. Several imaging modalities are currently utilized for detecting breast cancer, of which microwave imaging (MWI) is gaining quite a lot of attention as a promising diagnostic tool for early breast cancer detection. MWI is a noninvasive, relatively inexpensive, fast, convenient, and safe screening tool. The purpose of this paper is to provide an up-to-date survey of the principles, developments, and current research status of MWI for breast cancer detection. This paper is structured into two sections; the first is an overview of current MWI techniques used for detecting breast cancer, followed by an explanation of the working principle behind MWI and its various types, namely, microwave tomography and radar-based imaging. In the second section, a review of the initial experiments along with more recent studies on the use of MWI for breast cancer detection is presented. Furthermore, the paper summarizes the challenges facing MWI as a breast cancer detection tool and provides future research directions. On the whole, MWI has proven its potential as a screening tool for breast cancer detection, both as a standalone or complementary technique. However, there are a few challenges that need to be addressed to unlock the full potential of this imaging modality and translate it to clinical settings.

20 November 2009 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
CGColin Gilmore
Colin Gilmore
PMPuyan Mojabi
Puyan Mojabi
Amer ZakariaAmer Zakaria
Amer Zakaria
MOMajid Ostadrahimi
Majid Ostadrahimi
CKCameron Kaye
Cameron Kaye
JLJoe LoVetri
Joe LoVetri
In this paper, we describe a 2-D wideband microwave imaging system intended for biomedical imaging. The system is capable of collecting data from 3 to 6 GHz, with 24 coresident antenna elements connected to a vector network analyzer via a 2 × 24 port matrix switch. As one of the major sources of error in the data collection process is a result of the strongly coupling 24 coresident antennas, we provide a novel method to avoid the frequencies where the coupling is large enough to prevent successful imaging. Through the use of two different nonlinear reconstruction schemes, which are an enhanced version of the distorted born iterative method and the multiplicative regularized contrast source inversion method, we show imaging results from dielectric phantoms in free space. The early inversion results show that with the frequency selection procedure applied, the system is capable of quantitatively reconstructing dielectric objects, and show that the use of the wideband data improves the inversion results over single-frequency data.

30 September 2010 in Inverse Problems
Verified
Journal Article
Closed access
Amer ZakariaAmer Zakaria
Amer Zakaria
CGColin Gilmore
Colin Gilmore
JLJoe LoVetri
Joe LoVetri

1 September 2011 in IEEE Antennas and Wireless Propagation Letters
Verified
Journal Article
Closed access
MOMajid Ostadrahimi
Majid Ostadrahimi
PMPuyan Mojabi
Puyan Mojabi
CGColin Gilmore
Colin Gilmore
Amer ZakariaAmer Zakaria
Amer Zakaria
Sima NoghanianSima Noghanian
Sima Noghanian
JLJoe LoVetri
Joe LoVetri
Imaging with microwave tomography systems requires both the incident field within the imaging domain as well as calibration factors that convert the collected data to corresponding data in the numerical model used for inversion. The numerical model makes various simplifying assumptions, e.g., 2-D versus 3-D wave propagation, which the calibration coefficients are meant to take into account. For an air-based microwave tomography system, we study two types of calibration techniques-incident and scattered field calibration-combined with two different incident field models: a 2-D line-source and an incident field from full-wave 3-D simulation of the tomography system. Although the 2-D line-source approximation does not accurately model incident field in our system, the use of scattered field calibration with the 2-D line-source provides similar or better images to incident and scattered field calibration with an accurate incident field. Thus, if scattered field calibration is used, a simple (but inaccurate) incident field is acceptable for our microwave tomography system. While not strictly generalizable, we expect our methodology to be applicable to most other microwave tomography systems.

30 July 2013 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
MOMajid Ostadrahimi
Majid Ostadrahimi
PMPuyan Mojabi
Puyan Mojabi
Amer ZakariaAmer Zakaria
Amer Zakaria
JLJoe LoVetri
Joe LoVetri
LSLotfollah Shafai
Lotfollah Shafai
The multiplicatively regularized Gauss-Newton inversion (GNI) algorithm is enhanced and utilized to obtain complex permittivity profiles of biological objects-of-interest. The microwave scattering data is acquired using a microwave tomography system comprised of 24 co-resident antennas immersed into a saltwater matching fluid. Two types of biological targets are imaged: ex vivo bovine legs and in vivo human forearms. Four different forms of the GNI algorithm are implemented: a blind inversion, a balanced inversion, a shape-and-location inversion, and a novel balanced shape-and-location inversion. The latter three techniques incorporate typical permittivity values of biological tissues as prior information to enhance the reconstructions. In those images obtained using the balanced shape-and-location reconstruction algorithm, the various parts of the tissue being imaged are clearly distinguishable. The reconstructed permittivity values in the bovine leg images agree with those obtained via direct measurement using a dielectric probe. The reconstructed images of the human forearms qualitatively agree with magnetic resonance imaging images, as well as with the expected dielectric values obtained from the literature.

1 January 2013 in International Journal of Biomedical Imaging
Verified
Journal Article
Open access
PDF file
CGColin Gilmore
Colin Gilmore
Amer ZakariaAmer Zakaria
Amer Zakaria
Stephen PistoriusStephen Pistorius
Stephen Pistorius
JLJoe LoVetri
Joe LoVetri
We present a pilot study using a microwave tomography system in which we image the forearms of 5 adult male and female volunteers between the ages of 30 and 48. Microwave scattering data were collected at 0.8 to 1.2 GHz with 24 transmitting and receiving antennas located in a matching fluid of deionized water and table salt. Inversion of the microwave data was performed with a balanced version of the multiplicative-regularized contrast source inversion algorithm formulated using the finite-element method (FEM-CSI). T1-weighted MRI images of each volunteer’s forearm were also collected in the same plane as the microwave scattering experiment. Initial “blind” imaging results from the utilized inversion algorithm show that the image quality is dependent on the thickness of the arm’s peripheral adipose tissue layer; thicker layers of adipose tissue lead to poorer overall image quality. Due to the exible nature of the FEM-CSI algorithm used, prior information can be readily incorporated into the microwave imaging inversion process. We show that by introducing prior information into the FEM-CSI algorithm the internal anatomical features of all the arms are resolved, significantly improving the images. The prior information was estimated manually from the blind inversions using anad hocprocedure.